1. Home >
  2. WEIonline Shop >
  3. Manufacturers >
  4. Yokogawa >
  5. Analog Panel Meters >

Yokogawa | Analog DC Current Panel Meters - pg. 3 including Yokogawa 254300NGNG - DC AMP 0-LEFTRating- 0-20 A/DCScale- 0-20Legend- DC AMPERES


VIEW Yokogawa Panel Meter Catalog

Yokogawa 254300NGNG - DC AMP 0-LEFT Rating- 0-20 A/DC Scale- 0-20 Legend- DC AMPERES - Product Image

Yokogawa 254300NGNG - DC AMP 0-LEFT

Rating- 0-20 A/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.00
Yokogawa 254300NLNL - DC AMP 0-LEFT Rating- 0-30 A/DC Scale- 0-30 Legend- DC AMPERES - Product Image

Yokogawa 254300NLNL - DC AMP 0-LEFT

Rating- 0-30 A/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.00
Yokogawa 254300NTNT - DC AMP 0-LEFT Rating- 0-50 A/DC Scale- 0-50 Legend- DC AMPERES - Product Image

Yokogawa 254300NTNT - DC AMP 0-LEFT

Rating- 0-50 A/DC
Scale- 0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.00
Yokogawa 254301DRDR - DC AMP 0-CENTER Rating- 100-0-100 uA/DC Scale- 100-0-100 Legend- DC MICROAMPERES - Product Image

Yokogawa 254301DRDR - DC AMP 0-CENTER

Rating- 100-0-100 uA/DC
Scale- 100-0-100
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301EMEM - DC AMP 0-CENTER Rating- 500-0-500 uA/DC Scale- 500-0-500 Legend- DC MICROAMPERES - Product Image

Yokogawa 254301EMEM - DC AMP 0-CENTER

Rating- 500-0-500 uA/DC
Scale- 500-0-500
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301FAFA - DC AMP 0-CENTER Rating- 1-0-1 mA/DC Scale- 1-0-1 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301FAFA - DC AMP 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 1-0-1
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301FNFN - DC AMP 0-CENTER Rating- 3-0-3 mA/DC Scale- 3-0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301FNFN - DC AMP 0-CENTER

Rating- 3-0-3 mA/DC
Scale- 3-0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301FXFX - DC AMP 0-CENTER Rating- 5-0-5 mA/DC Scale- 5-0-5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301FXFX - DC AMP 0-CENTER

Rating- 5-0-5 mA/DC
Scale- 5-0-5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301GZGZ - DC AMP 0-CENTER Rating- 10-0-10 mA/DC Scale- 10-0-10 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301GZGZ - DC AMP 0-CENTER

Rating- 10-0-10 mA/DC
Scale- 10-0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301HFHF - DC AMP 0-CENTER Rating- 20-0-20 mA/DC Scale- 20-0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301HFHF - DC AMP 0-CENTER

Rating- 20-0-20 mA/DC
Scale- 20-0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301HJHJ - DC AMP 0-CENTER Rating- 25-0-25 mA/DC Scale- 25-0-25 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301HJHJ - DC AMP 0-CENTER

Rating- 25-0-25 mA/DC
Scale- 25-0-25
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301HMHM - DC AMP 0-CENTER Rating- 30-0-30 mA/DC Scale- 30-0-30 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301HMHM - DC AMP 0-CENTER

Rating- 30-0-30 mA/DC
Scale- 30-0-30
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301HYHY - DC AMP 0-CENTER Rating- 50-0-50 mA/DC Scale- 50-0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301HYHY - DC AMP 0-CENTER

Rating- 50-0-50 mA/DC
Scale- 50-0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301JRJR - DC AMP 0-CENTER Rating- 100-0-100 mA/DC Scale- 100-0-100 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301JRJR - DC AMP 0-CENTER

Rating- 100-0-100 mA/DC
Scale- 100-0-100
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301JXJX - DC AMP 0-CENTER Rating- 150-0-150 mA/DC Scale- 150-0-150 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301JXJX - DC AMP 0-CENTER

Rating- 150-0-150 mA/DC
Scale- 150-0-150
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301KAKA - DC AMP 0-CENTER Rating- 200-0-200 mA/DC Scale- 200-0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301KAKA - DC AMP 0-CENTER

Rating- 200-0-200 mA/DC
Scale- 200-0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301KDKD - DC AMP 0-CENTER Rating- 250-0-250 mA/DC Scale- 250-0-250 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301KDKD - DC AMP 0-CENTER

Rating- 250-0-250 mA/DC
Scale- 250-0-250
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301KGKG - DC AMP 0-CENTER Rating- 300-0-300 mA/DC Scale- 300-0-300 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301KGKG - DC AMP 0-CENTER

Rating- 300-0-300 mA/DC
Scale- 300-0-300
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301KMKM - DC AMP 0-CENTER Rating- 500-0-500 mA/DC Scale- 500-0-500 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254301KMKM - DC AMP 0-CENTER

Rating- 500-0-500 mA/DC
Scale- 500-0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301LALA - DC AMP 0-CENTER Rating- 1-0-1 A/DC Scale- 1-0-1 Legend- DC AMPERES - Product Image

Yokogawa 254301LALA - DC AMP 0-CENTER

Rating- 1-0-1 A/DC
Scale- 1-0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301LELE - DC AMP 0-CENTER Rating- 2-0-2 A/DC Scale- 2-0-2 Legend- DC AMPERES - Product Image

Yokogawa 254301LELE - DC AMP 0-CENTER

Rating- 2-0-2 A/DC
Scale- 2-0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301LSLS - DC AMP 0-CENTER Rating- 5-0-5 A/DC Scale- 5-0-5 Legend- DC AMPERES - Product Image

Yokogawa 254301LSLS - DC AMP 0-CENTER

Rating- 5-0-5 A/DC
Scale- 5-0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301MTMT - DC AMP 0-CENTER Rating- 10-0-10 A/DC Scale- 10-0-10 Legend- DC AMPERES - Product Image

Yokogawa 254301MTMT - DC AMP 0-CENTER

Rating- 10-0-10 A/DC
Scale- 10-0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301NDND - DC AMP 0-CENTER Rating- 15-0-15 A/DC Scale- 15-0-15 Legend- DC AMPERES - Product Image

Yokogawa 254301NDND - DC AMP 0-CENTER

Rating- 15-0-15 A/DC
Scale- 15-0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301NGNG - DC AMP 0-CENTER Rating- 20-0-20 A/DC Scale- 20-0-20 Legend- DC AMPERES - Product Image

Yokogawa 254301NGNG - DC AMP 0-CENTER

Rating- 20-0-20 A/DC
Scale- 20-0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301NLNL - DC AMP 0-CENTER Rating- 30-0-30 A/DC Scale- 30-0-30 Legend- DC AMPERES - Product Image

Yokogawa 254301NLNL - DC AMP 0-CENTER

Rating- 30-0-30 A/DC
Scale- 30-0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254301NTNT - DC AMP 0-CENTER Rating- 50-0-50 A/DC Scale- 50-0-50 Legend- DC AMPERES - Product Image

Yokogawa 254301NTNT - DC AMP 0-CENTER

Rating- 50-0-50 A/DC
Scale- 50-0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 254400EAEA - DC AMP 0-LEFT Rating- 0-200 uA/DC Scale- 0-200 Legend- DC MICROAMPERES - Product Image

Yokogawa 254400EAEA - DC AMP 0-LEFT

Rating- 0-200 uA/DC
Scale- 0-200
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400EMEM - DC AMP 0-LEFT Rating- 0-500 uA/AC Scale- 0-500 Legend- DC MICROAMPERES - Product Image

Yokogawa 254400EMEM - DC AMP 0-LEFT

Rating- 0-500 uA/AC
Scale- 0-500
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400FAFA - DC AMP 0-LEFT Rating- 0-1 mA/DC Scale- 0-1 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400FAFA - DC AMP 0-LEFT

Rating- 0-1 mA/DC
Scale- 0-1
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400FDFD - DC AMP 0-LEFT Rating- 0-1.5 mA/DC Scale- 0-1.5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400FDFD - DC AMP 0-LEFT

Rating- 0-1.5 mA/DC
Scale- 0-1.5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400FNFN - DC AMP 0-LEFT Rating- 0-3 mA/DC Scale- 0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400FNFN - DC AMP 0-LEFT

Rating- 0-3 mA/DC
Scale- 0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400FXFX - DC AMP 0-LEFT Rating- 0-5 mA/DC Scale- 0-5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400FXFX - DC AMP 0-LEFT

Rating- 0-5 mA/DC
Scale- 0-5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400GZGZ - DC AMP 0-LEFT Rating- 0-10 mA/DC Scale- 0-10 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400GZGZ - DC AMP 0-LEFT

Rating- 0-10 mA/DC
Scale- 0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400HFHF - DC AMP 0-LEFT Rating- 0-20 mA/DC Scale- 0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400HFHF - DC AMP 0-LEFT

Rating- 0-20 mA/DC
Scale- 0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400HJHJ - DC AMP 0-LEFT Rating- 0-25 mA/DC Scale- 0-25 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400HJHJ - DC AMP 0-LEFT

Rating- 0-25 mA/DC
Scale- 0-25
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400HMHM - DC AMP 0-LEFT Rating- 0-30 mA/DC Scale- 0-30 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400HMHM - DC AMP 0-LEFT

Rating- 0-30 mA/DC
Scale- 0-30
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400HYHY - DC AMP 0-LEFT Rating- 0-50 mA/DC Scale- 0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400HYHY - DC AMP 0-LEFT

Rating- 0-50 mA/DC
Scale- 0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400JJJJ - DC AMP 0-LEFT Rating- 0-80 mA/DC Scale- 0-80 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400JJJJ - DC AMP 0-LEFT

Rating- 0-80 mA/DC
Scale- 0-80
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400JRJR - DC AMP 0-LEFT Rating- 0-100 mA/DC Scale- 0-100 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400JRJR - DC AMP 0-LEFT

Rating- 0-100 mA/DC
Scale- 0-100
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400JXJX - DC AMP 0-LEFT Rating- 0-150 mA/DC Scale- 0-150 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400JXJX - DC AMP 0-LEFT

Rating- 0-150 mA/DC
Scale- 0-150
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400KAKA - DC AMP 0-LEFT Rating- 0-200 mA/DC Scale- 0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400KAKA - DC AMP 0-LEFT

Rating- 0-200 mA/DC
Scale- 0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400KDKD - DC AMP 0-LEFT Rating- 0-250 mA/DC Scale- 0-250 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400KDKD - DC AMP 0-LEFT

Rating- 0-250 mA/DC
Scale- 0-250
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400KGKG - DC AMP 0-LEFT Rating- 0-300 mA/DC Scale- 0-300 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400KGKG - DC AMP 0-LEFT

Rating- 0-300 mA/DC
Scale- 0-300
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400KMKM - DC AMP 0-LEFT Rating- 0-500 mA/DC Scale- 0-500 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400KMKM - DC AMP 0-LEFT

Rating- 0-500 mA/DC
Scale- 0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400KWKW - DC AMP 0-LEFT Rating- 0-800 mA/DC Scale- 0-800 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254400KWKW - DC AMP 0-LEFT

Rating- 0-800 mA/DC
Scale- 0-800
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400LALA - DC AMP 0-LEFT Rating- 0-1 A/DC Scale- 0-1 Legend- DC AMPERES - Product Image

Yokogawa 254400LALA - DC AMP 0-LEFT

Rating- 0-1 A/DC
Scale- 0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.00
Yokogawa 254400LCLC - DC AMP 0-LEFT Rating- 0-1.5 A/DC Scale- 0-1.5 Legend- DC AMPERES - Product Image

Yokogawa 254400LCLC - DC AMP 0-LEFT

Rating- 0-1.5 A/DC
Scale- 0-1.5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.00
Yokogawa 254400LELE - DC AMP 0-LEFT Rating- 0-2 A/DC Scale- 0-2 Legend- DC AMPERES - Product Image

Yokogawa 254400LELE - DC AMP 0-LEFT

Rating- 0-2 A/DC
Scale- 0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.00
Yokogawa 254400LJLJ - DC AMP 0-LEFT Rating- 0-3 A/DC Scale- 0-3 Legend- DC AMPERES - Product Image

Yokogawa 254400LJLJ - DC AMP 0-LEFT

Rating- 0-3 A/DC
Scale- 0-3
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.00
Yokogawa 254400LSLS - DC AMP 0-LEFT Rating- 0-5 A/DC Scale- 0-5 Legend- DC AMPERES - Product Image

Yokogawa 254400LSLS - DC AMP 0-LEFT

Rating- 0-5 A/DC
Scale- 0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.00
Yokogawa 254400MTMT - DC AMP 0-LEFT Rating- 0-10 A/DC Scale- 0-10 Legend- DC AMPERES - Product Image

Yokogawa 254400MTMT - DC AMP 0-LEFT

Rating- 0-10 A/DC
Scale- 0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400NDND - DC AMP 0-LEFT Rating- 0-15 A/DC Scale- 0-15 Legend- DC AMPERES - Product Image

Yokogawa 254400NDND - DC AMP 0-LEFT

Rating- 0-15 A/DC
Scale- 0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400NGNG - DC AMP 0-LEFT Rating- 0-20 A/DC Scale- 0-20 Legend- DC AMPERES - Product Image

Yokogawa 254400NGNG - DC AMP 0-LEFT

Rating- 0-20 A/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400NLNL - DC AMP 0-LEFT Rating- 0-30 A/DC Scale- 0-30 Legend- DC AMPERES - Product Image

Yokogawa 254400NLNL - DC AMP 0-LEFT

Rating- 0-30 A/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254400NTNT - DC AMP 0-LEFT Rating- 0-50 A/DC Scale- 0-50 Legend- DC AMPERES - Product Image

Yokogawa 254400NTNT - DC AMP 0-LEFT

Rating- 0-50 A/DC
Scale- 0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401DRDR - DC AMP 0-CENTER Rating- 100-0-100 uA/DC Scale- 100-0-100 Legend- DC MICROAMPERES - Product Image

Yokogawa 254401DRDR - DC AMP 0-CENTER

Rating- 100-0-100 uA/DC
Scale- 100-0-100
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401EAEA - DC AMP 0-CENTER Rating- 200-0-200 uA/DC Scale- 200-0-200 Legend- DC MICROAMPERES - Product Image

Yokogawa 254401EAEA - DC AMP 0-CENTER

Rating- 200-0-200 uA/DC
Scale- 200-0-200
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401EMEM - DC AMP 0-CENTER Rating- 500-0-500 uA/DC Scale- 500-0-500 Legend- DC MICROAMPERES - Product Image

Yokogawa 254401EMEM - DC AMP 0-CENTER

Rating- 500-0-500 uA/DC
Scale- 500-0-500
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401FAFA - DC AMP 0-CENTER Rating- 1-0-1 mA/DC Scale- 1-0-1 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401FAFA - DC AMP 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 1-0-1
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401FNFN - DC AMP 0-CENTER Rating- 3-0-3 mA/DC Scale- 3-0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401FNFN - DC AMP 0-CENTER

Rating- 3-0-3 mA/DC
Scale- 3-0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401FXFX - DC AMP 0-CENTER Rating- 5-0-5 mA/DC Scale- 5-0-5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401FXFX - DC AMP 0-CENTER

Rating- 5-0-5 mA/DC
Scale- 5-0-5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401GZGZ - DC AMP 0-CENTER Rating- 10-0-10 mA/DC Scale- 10-0-10 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401GZGZ - DC AMP 0-CENTER

Rating- 10-0-10 mA/DC
Scale- 10-0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401HFHF - DC AMP 0-CENTER Rating- 20-0-20 mA/DC Scale- 20-0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401HFHF - DC AMP 0-CENTER

Rating- 20-0-20 mA/DC
Scale- 20-0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401HJHJ - DC AMP 0-CENTER Rating- 25-0-25 mA/DC Scale- 25-0-25 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401HJHJ - DC AMP 0-CENTER

Rating- 25-0-25 mA/DC
Scale- 25-0-25
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401HMHM - DC AMP 0-CENTER Rating- 30-0-30 mA/DC Scale- 30-0-30 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401HMHM - DC AMP 0-CENTER

Rating- 30-0-30 mA/DC
Scale- 30-0-30
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401HYHY - DC AMP 0-CENTER Rating- 50-0-50 mA/DC Scale- 50-0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401HYHY - DC AMP 0-CENTER

Rating- 50-0-50 mA/DC
Scale- 50-0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401JRJR - DC AMP 0-CENTER Rating- 100-0-100 mA/DC Scale- 100-0-100 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401JRJR - DC AMP 0-CENTER

Rating- 100-0-100 mA/DC
Scale- 100-0-100
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401JXJX - DC AMP 0-CENTER Rating- 150-0-150 mA/DC Scale- 150-0-150 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401JXJX - DC AMP 0-CENTER

Rating- 150-0-150 mA/DC
Scale- 150-0-150
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401KAKA - DC AMP 0-CENTER Rating- 200-0-200 mA/DC Scale- 200-0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401KAKA - DC AMP 0-CENTER

Rating- 200-0-200 mA/DC
Scale- 200-0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401KDKD - DC AMP 0-CENTER Rating- 250-0-250 mA/DC Scale- 250-0-250 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401KDKD - DC AMP 0-CENTER

Rating- 250-0-250 mA/DC
Scale- 250-0-250
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401KGKG - DC AMP 0-CENTER Rating- 300-0-300 mA/DC Scale- 300-0-300 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401KGKG - DC AMP 0-CENTER

Rating- 300-0-300 mA/DC
Scale- 300-0-300
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401KMKM - DC AMP 0-CENTER Rating- 500-0-500 mA/DC Scale- 500-0-500 Legend- DC MILLIAMPERES - Product Image

Yokogawa 254401KMKM - DC AMP 0-CENTER

Rating- 500-0-500 mA/DC
Scale- 500-0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401LALA - DC AMP 0-CENTER Rating- 1-0-1 A/DC Scale- 1-0-1 Legend- DC AMPERES - Product Image

Yokogawa 254401LALA - DC AMP 0-CENTER

Rating- 1-0-1 A/DC
Scale- 1-0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401LELE - DC AMP 0-CENTER Rating- 2-0-2 A/DC Scale- 2-0-2 Legend- DC AMPERES - Product Image

Yokogawa 254401LELE - DC AMP 0-CENTER

Rating- 2-0-2 A/DC
Scale- 2-0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401LSLS - DC AMP 0-CENTER Rating- 5-0-5 A/DC Scale- 5-0-5 Legend- DC AMPERES - Product Image

Yokogawa 254401LSLS - DC AMP 0-CENTER

Rating- 5-0-5 A/DC
Scale- 5-0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401MTMT - DC AMP 0-CENTER Rating- 10-0-10 A/DC Scale- 10-0-10 Legend- DC AMPERES - Product Image

Yokogawa 254401MTMT - DC AMP 0-CENTER

Rating- 10-0-10 A/DC
Scale- 10-0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401NDND - DC AMP 0-CENTER Rating- 15-0-15 A/DC Scale- 15-0-15 Legend- DC AMPERES - Product Image

Yokogawa 254401NDND - DC AMP 0-CENTER

Rating- 15-0-15 A/DC
Scale- 15-0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401NGNG - DC AMP 0-CENTER Rating- 20-0-20 A/DC Scale- 20-0-20 Legend- DC AMPERES - Product Image

Yokogawa 254401NGNG - DC AMP 0-CENTER

Rating- 20-0-20 A/DC
Scale- 20-0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401NLNL - DC AMP 0-CENTER Rating- 30-0-30 A/DC Scale- 30-0-30 Legend- DC AMPERES - Product Image

Yokogawa 254401NLNL - DC AMP 0-CENTER

Rating- 30-0-30 A/DC
Scale- 30-0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254401NTNT - DC AMP 0-CENTER Rating- 50-0-50 A/DC Scale- 50-0-50 Legend- DC AMPERES - Product Image

Yokogawa 254401NTNT - DC AMP 0-CENTER

Rating- 50-0-50 A/DC
Scale- 50-0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254404FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT Rating- 0-1 mA/DC Scale- 0-750 Legend- DC VOLTS - Product Image

Yokogawa 254404FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT

Rating- 0-1 mA/DC
Scale- 0-750
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 254405FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER Rating- 1-0-1 mA/DC Scale- 750-0-750 Legend- DC VOLTS - Product Image

Yokogawa 254405FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 750-0-750
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 255200EAEA - DC AMP 0-LEFT Rating- 0-200 uA/DC Scale- 0-200 Legend- DC MICROAMPERES - Product Image

Yokogawa 255200EAEA - DC AMP 0-LEFT

Rating- 0-200 uA/DC
Scale- 0-200
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200EMEM - DC AMP 0-LEFT Rating- 0-500 uA/DC Scale- 0-500 Legend- DC MICROAMPERES - Product Image

Yokogawa 255200EMEM - DC AMP 0-LEFT

Rating- 0-500 uA/DC
Scale- 0-500
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200EWEW - DC AMP 0-LEFT Rating- 0-800 uA/DC Scale- 0-800 Legend- DC MICROAMPERES - Product Image

Yokogawa 255200EWEW - DC AMP 0-LEFT

Rating- 0-800 uA/DC
Scale- 0-800
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200FAFA - DC AMP 0-LEFT Rating- 0-1 mA/DC Scale- 0-1 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200FAFA - DC AMP 0-LEFT

Rating- 0-1 mA/DC
Scale- 0-1
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200FDFD - DC AMP 0-LEFT Rating- 0-1.5 mA/DC Scale- 0-1.5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200FDFD - DC AMP 0-LEFT

Rating- 0-1.5 mA/DC
Scale- 0-1.5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200FNFN - DC AMP 0-LEFT Rating- 0-3 mA/DC Scale- 0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200FNFN - DC AMP 0-LEFT

Rating- 0-3 mA/DC
Scale- 0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200FXFX - DC AMP 0-LEFT Rating- 0-5 mA/DC Scale- 0-5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200FXFX - DC AMP 0-LEFT

Rating- 0-5 mA/DC
Scale- 0-5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200GZGZ - DC AMP 0-LEFT Rating- 0-10 mA/DC Scale- 0-10 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200GZGZ - DC AMP 0-LEFT

Rating- 0-10 mA/DC
Scale- 0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200HFHF - DC AMP 0-LEFT Rating- 0-20 mA/DC Scale- 0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200HFHF - DC AMP 0-LEFT

Rating- 0-20 mA/DC
Scale- 0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200HJHJ - DC AMP 0-LEFT Rating- 0-25 mA/DC Scale- 0-25 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200HJHJ - DC AMP 0-LEFT

Rating- 0-25 mA/DC
Scale- 0-25
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200HMHM - DC AMP 0-LEFT Rating- 0-30 mA/DC Scale- 0-30 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200HMHM - DC AMP 0-LEFT

Rating- 0-30 mA/DC
Scale- 0-30
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200HYHY - DC AMP 0-LEFT Rating- 0-50 mA/DC Scale- 0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200HYHY - DC AMP 0-LEFT

Rating- 0-50 mA/DC
Scale- 0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200JJJJ - DC AMP 0-LEFT Rating- 0-80 mA/DC Scale- 0-80 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200JJJJ - DC AMP 0-LEFT

Rating- 0-80 mA/DC
Scale- 0-80
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200JRJR - DC AMP 0-LEFT Rating- 0-100 mA/DC Scale- 0-100 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200JRJR - DC AMP 0-LEFT

Rating- 0-100 mA/DC
Scale- 0-100
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200JXJX - DC AMP 0-LEFT Rating- 0-150 mA/DC Scale- 0-150 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200JXJX - DC AMP 0-LEFT

Rating- 0-150 mA/DC
Scale- 0-150
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200KAKA - DC AMP 0-LEFT Rating- 0-200 mA/DC Scale- 0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200KAKA - DC AMP 0-LEFT

Rating- 0-200 mA/DC
Scale- 0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200KDKD - DC AMP 0-LEFT Rating- 0-250 mA/DC Scale- 0-250 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200KDKD - DC AMP 0-LEFT

Rating- 0-250 mA/DC
Scale- 0-250
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200KGKG - DC AMP 0-LEFT Rating- 0-300 mA/DC Scale- 0-300 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200KGKG - DC AMP 0-LEFT

Rating- 0-300 mA/DC
Scale- 0-300
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200KMKM - DC AMP 0-LEFT Rating- 0-500 mA/DC Scale- 0-500 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200KMKM - DC AMP 0-LEFT

Rating- 0-500 mA/DC
Scale- 0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200KWKW - DC AMP 0-LEFT Rating- 0-800 mA/DC Scale- 0-800 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255200KWKW - DC AMP 0-LEFT

Rating- 0-800 mA/DC
Scale- 0-800
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200LALA - DC AMP 0-LEFT Rating- 0-1 A/DC Scale- 0-1 Legend- DC AMPERES - Product Image

Yokogawa 255200LALA - DC AMP 0-LEFT

Rating- 0-1 A/DC
Scale- 0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200LCLC - DC AMP 0-LEFT Rating- 0-1.5 A/DC Scale- 0-1.5 Legend- DC AMPERES - Product Image

Yokogawa 255200LCLC - DC AMP 0-LEFT

Rating- 0-1.5 A/DC
Scale- 0-1.5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200LELE - DC AMP 0-LEFT Rating- 0-2 A/DC Scale- 0-2 Legend- DC AMPERES - Product Image

Yokogawa 255200LELE - DC AMP 0-LEFT

Rating- 0-2 A/DC
Scale- 0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200LJLJ - DC AMP 0-LEFT Rating- 0-3 A/DC Scale- 0-3 Legend- DC AMPERES - Product Image

Yokogawa 255200LJLJ - DC AMP 0-LEFT

Rating- 0-3 A/DC
Scale- 0-3
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200LSLS - DC AMP 0-LEFT Rating- 0-5 A/DC Scale- 0-5 Legend- DC AMPERES - Product Image

Yokogawa 255200LSLS - DC AMP 0-LEFT

Rating- 0-5 A/DC
Scale- 0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200MTMT - DC AMP 0-LEFT Rating- 0-10 A/DC Scale- 0-10 Legend- DC AMPERES - Product Image

Yokogawa 255200MTMT - DC AMP 0-LEFT

Rating- 0-10 A/DC
Scale- 0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200NDND - DC AMP 0-LEFT Rating- 0-15 A/DC Scale- 0-15 Legend- DC AMPERES - Product Image

Yokogawa 255200NDND - DC AMP 0-LEFT

Rating- 0-15 A/DC
Scale- 0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200NGNG - DC AMP 0-LEFT Rating- 0-20 A/DC Scale- 0-20 Legend- DC AMPERES - Product Image

Yokogawa 255200NGNG - DC AMP 0-LEFT

Rating- 0-20 A/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255200NLNL - DC AMP 0-LEFT Rating- 0-30 A/DC Scale- 0-30 Legend- DC AMPERES - Product Image

Yokogawa 255200NLNL - DC AMP 0-LEFT

Rating- 0-30 A/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201DRDR - DC AMP 0-CENTER Rating- 100-0-100 uA/DC Scale- 100-0-100 Legend- DC MICROAMPERES - Product Image

Yokogawa 255201DRDR - DC AMP 0-CENTER

Rating- 100-0-100 uA/DC
Scale- 100-0-100
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201EAEA - DC AMP 0-CENTER Rating- 200-0-200 uA/DC Scale- 200-0-200 Legend- DC MICROAMPERES - Product Image

Yokogawa 255201EAEA - DC AMP 0-CENTER

Rating- 200-0-200 uA/DC
Scale- 200-0-200
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201EMEM - DC AMP 0-CENTER Rating- 500-0-500 uA/DC Scale- 500-0-500 Legend- DC MICROAMPERES - Product Image

Yokogawa 255201EMEM - DC AMP 0-CENTER

Rating- 500-0-500 uA/DC
Scale- 500-0-500
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201FAFA - DC AMP 0-CENTER Rating- 1-0-1 mA/DC Scale- 1-0-1 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201FAFA - DC AMP 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 1-0-1
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201FNFN - DC AMP 0-CENTER Rating- 3-0-3 mA/DC Scale- 3-0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201FNFN - DC AMP 0-CENTER

Rating- 3-0-3 mA/DC
Scale- 3-0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201FXFX - DC AMP 0-CENTER Rating- 5-0-5 mA/DC Scale- 5-0-5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201FXFX - DC AMP 0-CENTER

Rating- 5-0-5 mA/DC
Scale- 5-0-5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201GZGZ - DC AMP 0-CENTER Rating- 10-0-10 mA/DC Scale- 10-0-10 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201GZGZ - DC AMP 0-CENTER

Rating- 10-0-10 mA/DC
Scale- 10-0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201HFHF - DC AMP 0-CENTER Rating- 20-0-20 mA/DC Scale- 20-0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201HFHF - DC AMP 0-CENTER

Rating- 20-0-20 mA/DC
Scale- 20-0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201HJHJ - DC AMP 0-CENTER Rating- 25-0-25 mA/DC Scale- 25-0-25 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201HJHJ - DC AMP 0-CENTER

Rating- 25-0-25 mA/DC
Scale- 25-0-25
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201HMHM - DC AMP 0-CENTER Rating- 30-0-30 mA/DC Scale- 30-0-30 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201HMHM - DC AMP 0-CENTER

Rating- 30-0-30 mA/DC
Scale- 30-0-30
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201HYHY - DC AMP 0-CENTER Rating- 50-0-50 mA/DC Scale- 50-0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201HYHY - DC AMP 0-CENTER

Rating- 50-0-50 mA/DC
Scale- 50-0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201JRJR - DC AMP 0-CENTER Rating- 100-0-100 mA/DC Scale- 100-0-100 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201JRJR - DC AMP 0-CENTER

Rating- 100-0-100 mA/DC
Scale- 100-0-100
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201JXJX - DC AMP 0-CENTER Rating- 150-0-150 mA/DC Scale- 150-0-150 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201JXJX - DC AMP 0-CENTER

Rating- 150-0-150 mA/DC
Scale- 150-0-150
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201KAKA - DC AMP 0-CENTER Rating- 200-0-200 mA/DC Scale- 200-0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201KAKA - DC AMP 0-CENTER

Rating- 200-0-200 mA/DC
Scale- 200-0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201KDKD - DC AMP 0-CENTER Rating- 250-0-250 mA/DC Scale- 250-0-250 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201KDKD - DC AMP 0-CENTER

Rating- 250-0-250 mA/DC
Scale- 250-0-250
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201KGKG - DC AMP 0-CENTER Rating- 300-0-300 mA/DC Scale- 300-0-300 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201KGKG - DC AMP 0-CENTER

Rating- 300-0-300 mA/DC
Scale- 300-0-300
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201KMKM - DC AMP 0-CENTER Rating- 500-0-500 mA/DC Scale- 500-0-500 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255201KMKM - DC AMP 0-CENTER

Rating- 500-0-500 mA/DC
Scale- 500-0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201LALA - DC AMP 0-CENTER Rating- 1-0-1 A/DC mA/DC Scale- 1-0-1 Legend- DC AMPERES - Product Image

Yokogawa 255201LALA - DC AMP 0-CENTER

Rating- 1-0-1 A/DC mA/DC
Scale- 1-0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201LELE - DC AMP 0-CENTER Rating- 1.5-0-1.5 A/DC Scale- 1.5-0-1.5 Legend- DC AMPERES - Product Image

Yokogawa 255201LELE - DC AMP 0-CENTER

Rating- 1.5-0-1.5 A/DC
Scale- 1.5-0-1.5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201LJLJ - DC AMP 0-CENTER Rating- 3-0-3 A/DC Scale- 3-0-3 Legend- DC AMPERES - Product Image

Yokogawa 255201LJLJ - DC AMP 0-CENTER

Rating- 3-0-3 A/DC
Scale- 3-0-3
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201LSLS - DC AMP 0-CENTER Rating- 5-0-5 A/DC Scale- 5-0-5 Legend- DC AMPERES - Product Image

Yokogawa 255201LSLS - DC AMP 0-CENTER

Rating- 5-0-5 A/DC
Scale- 5-0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201MTMT - DC AMP 0-CENTER Rating- 10-0-10 A/DC Scale- 10-0-10 Legend- DC AMPERES - Product Image

Yokogawa 255201MTMT - DC AMP 0-CENTER

Rating- 10-0-10 A/DC
Scale- 10-0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201NDND - DC AMP 0-CENTER Rating- 15-0-15 A/DC Scale- 15-0-15 Legend- DC AMPERES - Product Image

Yokogawa 255201NDND - DC AMP 0-CENTER

Rating- 15-0-15 A/DC
Scale- 15-0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201NGNG - DC AMP 0-CENTER Rating- 20-0-20 A/DC Scale- 20-0-20 Legend- DC AMPERES - Product Image

Yokogawa 255201NGNG - DC AMP 0-CENTER

Rating- 20-0-20 A/DC
Scale- 20-0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255201NLNL - DC AMP 0-CENTER Rating- 30-0-30 A/DC Scale- 30-0-30 Legend- DC AMPERES - Product Image

Yokogawa 255201NLNL - DC AMP 0-CENTER

Rating- 30-0-30 A/DC
Scale- 30-0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255204FASF - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT Rating- 0-1 mA/DC Scale- 0-500 Legend- DC VOLTS - Product Image

Yokogawa 255204FASF - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT

Rating- 0-1 mA/DC
Scale- 0-500
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255204FASJ - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT Rating- 0-1 mA/DC Scale- 0-600 Legend- DC VOLTS - Product Image

Yokogawa 255204FASJ - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT

Rating- 0-1 mA/DC
Scale- 0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255204FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT Rating- 0-1 mA/DC Scale- 0-750 Legend- DC VOLTS - Product Image

Yokogawa 255204FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT

Rating- 0-1 mA/DC
Scale- 0-750
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255205FASF - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER Rating- 1-0-1 mA/DC Scale- 500-0-500 Legend- DC VOLTS - Product Image

Yokogawa 255205FASF - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 500-0-500
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255205FASJ - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER Rating- 1-0-1 mA/DC Scale- 600-0-600 Legend- DC VOLTS - Product Image

Yokogawa 255205FASJ - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 600-0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255205FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER Rating- 1-0-1 mA/DC Scale- 750-0-750 Legend- DC VOLTS - Product Image

Yokogawa 255205FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 750-0-750
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $57.00
Yokogawa 255300EMEM - DC AMP 0-LEFT Rating- 0-500 uA/DC Scale- 0-500 Legend- DC MICROAMPERES - Product Image

Yokogawa 255300EMEM - DC AMP 0-LEFT

Rating- 0-500 uA/DC
Scale- 0-500
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300FAFA - DC AMP 0-LEFT Rating- 0-1 mA/DC Scale- 0-1 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300FAFA - DC AMP 0-LEFT

Rating- 0-1 mA/DC
Scale- 0-1
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300FDFD - DC AMP 0-LEFT Rating- 0-1.5 mA/DC Scale- 0-1.5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300FDFD - DC AMP 0-LEFT

Rating- 0-1.5 mA/DC
Scale- 0-1.5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300FNFN - DC AMP 0-LEFT Rating- 0-3 mA/DC Scale- 0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300FNFN - DC AMP 0-LEFT

Rating- 0-3 mA/DC
Scale- 0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300FXFX - DC AMP 0-LEFT Rating- 0-5 mA/DC Scale- 0-5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300FXFX - DC AMP 0-LEFT

Rating- 0-5 mA/DC
Scale- 0-5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300GZGZ - DC AMP 0-LEFT Rating- 0-10 mA/DC Scale- 0-10 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300GZGZ - DC AMP 0-LEFT

Rating- 0-10 mA/DC
Scale- 0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300HFHF - DC AMP 0-LEFT Rating- 0-20 mA/DC Scale- 0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300HFHF - DC AMP 0-LEFT

Rating- 0-20 mA/DC
Scale- 0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300HJHJ - DC AMP 0-LEFT Rating- 0-25 mA/DC Scale- 0-25 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300HJHJ - DC AMP 0-LEFT

Rating- 0-25 mA/DC
Scale- 0-25
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300HMHM - DC AMP 0-LEFT Rating- 0-30 mA/DC Scale- 0-30 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300HMHM - DC AMP 0-LEFT

Rating- 0-30 mA/DC
Scale- 0-30
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300HYHY - DC AMP 0-LEFT Rating- 0-50 mA/DC Scale- 0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300HYHY - DC AMP 0-LEFT

Rating- 0-50 mA/DC
Scale- 0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300JJJJ - DC AMP 0-LEFT Rating- 0-80 mA/DC Scale- 0-80 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300JJJJ - DC AMP 0-LEFT

Rating- 0-80 mA/DC
Scale- 0-80
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300JRJR - DC AMP 0-LEFT Rating- 0-100 mA/DC Scale- 0-100 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300JRJR - DC AMP 0-LEFT

Rating- 0-100 mA/DC
Scale- 0-100
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings


General Specifications
 
 Price: $58.00
Yokogawa 255300JXJX - DC AMP 0-LEFT Rating- 0-150 mA/DC Scale- 0-150 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300JXJX - DC AMP 0-LEFT

Rating- 0-150 mA/DC
Scale- 0-150
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300KAKA - DC AMP 0-LEFT Rating- 0-200 mA/DC Scale- 0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300KAKA - DC AMP 0-LEFT

Rating- 0-200 mA/DC
Scale- 0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300KDKD - DC AMP 0-LEFT Rating- 0-250 mA/DC Scale- 0-250 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300KDKD - DC AMP 0-LEFT

Rating- 0-250 mA/DC
Scale- 0-250
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300KGKG - DC AMP 0-LEFT Rating- 0-300 mA/DC Scale- 0-300 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300KGKG - DC AMP 0-LEFT

Rating- 0-300 mA/DC
Scale- 0-300
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300KMKM - DC AMP 0-LEFT Rating- 0-500 mA/DC Scale- 0-500 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300KMKM - DC AMP 0-LEFT

Rating- 0-500 mA/DC
Scale- 0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300KWKW - DC AMP 0-LEFT Rating- 0-800 mA/DC Scale- 0-800 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255300KWKW - DC AMP 0-LEFT

Rating- 0-800 mA/DC
Scale- 0-800
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300LALA - DC AMP 0-LEFT Rating- 0-1 A/DC Scale- 0-1 Legend- DC AMPERES - Product Image

Yokogawa 255300LALA - DC AMP 0-LEFT

Rating- 0-1 A/DC
Scale- 0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300LCLC - DC AMP 0-LEFT Rating- 0-1.5 A/DC Scale- 0-1.5 Legend- DC AMPERES - Product Image

Yokogawa 255300LCLC - DC AMP 0-LEFT

Rating- 0-1.5 A/DC
Scale- 0-1.5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300LELE - DC AMP 0-LEFT Rating- 0-2 A/DC Scale- 0-2 Legend- DC AMPERES - Product Image

Yokogawa 255300LELE - DC AMP 0-LEFT

Rating- 0-2 A/DC
Scale- 0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300LJLJ - DC AMP 0-LEFT Rating- 0-3 A/DC Scale- 0-3 Legend- DC AMPERES - Product Image

Yokogawa 255300LJLJ - DC AMP 0-LEFT

Rating- 0-3 A/DC
Scale- 0-3
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300LSLS - DC AMP 0-LEFT Rating- 0-5 A/DC Scale- 0-5 Legend- DC AMPERES - Product Image

Yokogawa 255300LSLS - DC AMP 0-LEFT

Rating- 0-5 A/DC
Scale- 0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300MTMT - DC AMP 0-LEFT Rating- 0-10 A/DC Scale- 0-10 Legend- DC AMPERES - Product Image

Yokogawa 255300MTMT - DC AMP 0-LEFT

Rating- 0-10 A/DC
Scale- 0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300NDND - DC AMP 0-LEFT Rating- 0-15 A/DC Scale- 0-15 Legend- DC AMPERES - Product Image

Yokogawa 255300NDND - DC AMP 0-LEFT

Rating- 0-15 A/DC
Scale- 0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300NGNG - DC AMP 0-LEFT Rating- 0-20 A/DC Scale- 0-20 Legend- DC AMPERES - Product Image

Yokogawa 255300NGNG - DC AMP 0-LEFT

Rating- 0-20 A/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300NLNL - DC AMP 0-LEFT Rating- 0-30 A/DC Scale- 0-30 Legend- DC AMPERES - Product Image

Yokogawa 255300NLNL - DC AMP 0-LEFT

Rating- 0-30 A/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255300NTNT - DC AMP 0-LEFT Rating- 0-50 A/DC Scale- 0-50 Legend- DC AMPERES - Product Image

Yokogawa 255300NTNT - DC AMP 0-LEFT

Rating- 0-50 A/DC
Scale- 0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301DRDR - DC AMP 0-CENTER Rating- 100-0-100 uA/DC Scale- 100-0-100 Legend- DC MICROAMPERES - Product Image

Yokogawa 255301DRDR - DC AMP 0-CENTER

Rating- 100-0-100 uA/DC
Scale- 100-0-100
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301EMEM - DC AMP 0-CENTER Rating- 500-0-500 uA/DC Scale- 500-0-500 Legend- DC MICROAMPERES - Product Image

Yokogawa 255301EMEM - DC AMP 0-CENTER

Rating- 500-0-500 uA/DC
Scale- 500-0-500
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301FAFA - DC AMP 0-CENTER Rating- 1-0-1 mA/DC Scale- 1-0-1 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301FAFA - DC AMP 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 1-0-1
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301FNFN - DC AMP 0-CENTER Rating- 3-0-3 mA/DC Scale- 3-0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301FNFN - DC AMP 0-CENTER

Rating- 3-0-3 mA/DC
Scale- 3-0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301FXFX - DC AMP 0-CENTER Rating- 5-0-5 mA/DC Scale- 5-0-5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301FXFX - DC AMP 0-CENTER

Rating- 5-0-5 mA/DC
Scale- 5-0-5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301GZGZ - DC AMP 0-CENTER Rating- 10-0-10 mA/DC Scale- 10-0-10 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301GZGZ - DC AMP 0-CENTER

Rating- 10-0-10 mA/DC
Scale- 10-0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301HFHF - DC AMP 0-CENTER Rating- 20-0-20 mA/DC Scale- 20-0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301HFHF - DC AMP 0-CENTER

Rating- 20-0-20 mA/DC
Scale- 20-0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301HJHJ - DC AMP 0-CENTER Rating- 25-0-25 mA/DC Scale- 25-0-25 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301HJHJ - DC AMP 0-CENTER

Rating- 25-0-25 mA/DC
Scale- 25-0-25
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301HMHM - DC AMP 0-CENTER Rating- 30-0-30 mA/DC Scale- 30-0-30 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301HMHM - DC AMP 0-CENTER

Rating- 30-0-30 mA/DC
Scale- 30-0-30
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301HYHY - DC AMP 0-CENTER Rating- 50-0-50 mA/DC Scale- 50-0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301HYHY - DC AMP 0-CENTER

Rating- 50-0-50 mA/DC
Scale- 50-0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301JRJR - DC AMP 0-CENTER Rating- 100-0-100 mA/DC Scale- 100-0-100 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301JRJR - DC AMP 0-CENTER

Rating- 100-0-100 mA/DC
Scale- 100-0-100
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301JXJX - DC AMP 0-CENTER Rating- 150-0-150 mA/DC Scale- 150-0-150 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301JXJX - DC AMP 0-CENTER

Rating- 150-0-150 mA/DC
Scale- 150-0-150
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301KAKA - DC AMP 0-CENTER Rating- 200-0-200 mA/DC Scale- 200-0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301KAKA - DC AMP 0-CENTER

Rating- 200-0-200 mA/DC
Scale- 200-0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301KDKD - DC AMP 0-CENTER Rating- 250-0-250 mA/DC Scale- 250-0-250 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301KDKD - DC AMP 0-CENTER

Rating- 250-0-250 mA/DC
Scale- 250-0-250
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301KGKG - DC AMP 0-CENTER Rating- 300-0-300 mA/DC Scale- 300-0-300 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301KGKG - DC AMP 0-CENTER

Rating- 300-0-300 mA/DC
Scale- 300-0-300
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301KMKM - DC AMP 0-CENTER Rating- 500-0-500 mA/DC Scale- 500-0-500 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255301KMKM - DC AMP 0-CENTER

Rating- 500-0-500 mA/DC
Scale- 500-0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301LALA - DC AMP 0-CENTER Rating- 1-0-1 A/DC Scale- 1-0-1 Legend- DC AMPERES - Product Image

Yokogawa 255301LALA - DC AMP 0-CENTER

Rating- 1-0-1 A/DC
Scale- 1-0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301LELE - DC AMP 0-CENTER Rating- 2-0-2 A/DC Scale- 2-0-2 Legend- DC AMPERES - Product Image

Yokogawa 255301LELE - DC AMP 0-CENTER

Rating- 2-0-2 A/DC
Scale- 2-0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301LSLS - DC AMP 0-CENTER Rating- 5-0-5 A/DC Scale- 5-0-5 Legend- DC AMPERES - Product Image

Yokogawa 255301LSLS - DC AMP 0-CENTER

Rating- 5-0-5 A/DC
Scale- 5-0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301MTMT - DC AMP 0-CENTER Rating- 10-0-10 A/DC Scale- 10-0-10 Legend- DC AMPERES - Product Image

Yokogawa 255301MTMT - DC AMP 0-CENTER

Rating- 10-0-10 A/DC
Scale- 10-0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301NDND - DC AMP 0-CENTER Rating- 15-0-15 A/DC Scale- 15-0-15 Legend- DC AMPERES - Product Image

Yokogawa 255301NDND - DC AMP 0-CENTER

Rating- 15-0-15 A/DC
Scale- 15-0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301NGNG - DC AMP 0-CENTER Rating- 20-0-20 A/DC Scale- 20-0-20 Legend- DC AMPERES - Product Image

Yokogawa 255301NGNG - DC AMP 0-CENTER

Rating- 20-0-20 A/DC
Scale- 20-0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301NLNL - DC AMP 0-CENTER Rating- 30-0-30 A/DC Scale- 30-0-30 Legend- DC AMPERES - Product Image

Yokogawa 255301NLNL - DC AMP 0-CENTER

Rating- 30-0-30 A/DC
Scale- 30-0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255301NTNT - DC AMP 0-CENTER Rating- 50-0-50 A/DC Scale- 50-0-50 Legend- DC AMPERES - Product Image

Yokogawa 255301NTNT - DC AMP 0-CENTER

Rating- 50-0-50 A/DC
Scale- 50-0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $58.00
Yokogawa 255400EAEA - DC AMP 0-LEFT Rating- 0-200 uA/DC Scale- 0-200 Legend- DC MICROAMPERES - Product Image

Yokogawa 255400EAEA - DC AMP 0-LEFT

Rating- 0-200 uA/DC
Scale- 0-200
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400EMEM - DC AMP 0-LEFT Rating- 0-500 uA/AC Scale- 0-500 Legend- DC MICROAMPERES - Product Image

Yokogawa 255400EMEM - DC AMP 0-LEFT

Rating- 0-500 uA/AC
Scale- 0-500
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400FAFA - DC AMP 0-LEFT Rating- 0-1 mA/DC Scale- 0-1 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400FAFA - DC AMP 0-LEFT

Rating- 0-1 mA/DC
Scale- 0-1
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400FDFD - DC AMP 0-LEFT Rating- 0-1.5 mA/DC Scale- 0-1.5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400FDFD - DC AMP 0-LEFT

Rating- 0-1.5 mA/DC
Scale- 0-1.5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400FNFN - DC AMP 0-LEFT Rating- 0-3 mA/DC Scale- 0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400FNFN - DC AMP 0-LEFT

Rating- 0-3 mA/DC
Scale- 0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400FXFX - DC AMP 0-LEFT Rating- 0-5 mA/DC Scale- 0-5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400FXFX - DC AMP 0-LEFT

Rating- 0-5 mA/DC
Scale- 0-5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400GZGZ - DC AMP 0-LEFT Rating- 0-10 mA/DC Scale- 0-10 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400GZGZ - DC AMP 0-LEFT

Rating- 0-10 mA/DC
Scale- 0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400HFHF - DC AMP 0-LEFT Rating- 0-20 mA/DC Scale- 0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400HFHF - DC AMP 0-LEFT

Rating- 0-20 mA/DC
Scale- 0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400HJHJ - DC AMP 0-LEFT Rating- 0-25 mA/DC Scale- 0-25 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400HJHJ - DC AMP 0-LEFT

Rating- 0-25 mA/DC
Scale- 0-25
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400HMHM - DC AMP 0-LEFT Rating- 0-30 mA/DC Scale- 0-30 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400HMHM - DC AMP 0-LEFT

Rating- 0-30 mA/DC
Scale- 0-30
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400HYHY - DC AMP 0-LEFT Rating- 0-50 mA/DC Scale- 0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400HYHY - DC AMP 0-LEFT

Rating- 0-50 mA/DC
Scale- 0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400JJJJ - DC AMP 0-LEFT Rating- 0-80 mA/DC Scale- 0-80 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400JJJJ - DC AMP 0-LEFT

Rating- 0-80 mA/DC
Scale- 0-80
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400JRJR - DC AMP 0-LEFT Rating- 0-100 mA/DC Scale- 0-100 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400JRJR - DC AMP 0-LEFT

Rating- 0-100 mA/DC
Scale- 0-100
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400JXJX - DC AMP 0-LEFT Rating- 0-150 mA/DC Scale- 0-150 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400JXJX - DC AMP 0-LEFT

Rating- 0-150 mA/DC
Scale- 0-150
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400KAKA - DC AMP 0-LEFT Rating- 0-200 mA/DC Scale- 0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400KAKA - DC AMP 0-LEFT

Rating- 0-200 mA/DC
Scale- 0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400KDKD - DC AMP 0-LEFT Rating- 0-250 mA/DC Scale- 0-250 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400KDKD - DC AMP 0-LEFT

Rating- 0-250 mA/DC
Scale- 0-250
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400KGKG - DC AMP 0-LEFT Rating- 0-300 mA/DC Scale- 0-300 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400KGKG - DC AMP 0-LEFT

Rating- 0-300 mA/DC
Scale- 0-300
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400KMKM - DC AMP 0-LEFT Rating- 0-500 mA/DC Scale- 0-500 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400KMKM - DC AMP 0-LEFT

Rating- 0-500 mA/DC
Scale- 0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400KWKW - DC AMP 0-LEFT Rating- 0-800 mA/DC Scale- 0-800 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255400KWKW - DC AMP 0-LEFT

Rating- 0-800 mA/DC
Scale- 0-800
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400LALA - DC AMP 0-LEFT Rating- 0-1 A/DC Scale- 0-1 Legend- DC AMPERES - Product Image

Yokogawa 255400LALA - DC AMP 0-LEFT

Rating- 0-1 A/DC
Scale- 0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400LCLC - DC AMP 0-LEFT Rating- 0-1.5 A/DC Scale- 0-1.5 Legend- DC AMPERES - Product Image

Yokogawa 255400LCLC - DC AMP 0-LEFT

Rating- 0-1.5 A/DC
Scale- 0-1.5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400LELE - DC AMP 0-LEFT Rating- 0-2 A/DC Scale- 0-2 Legend- DC AMPERES - Product Image

Yokogawa 255400LELE - DC AMP 0-LEFT

Rating- 0-2 A/DC
Scale- 0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400LJLJ - DC AMP 0-LEFT Rating- 0-3 A/DC Scale- 0-3 Legend- DC AMPERES - Product Image

Yokogawa 255400LJLJ - DC AMP 0-LEFT

Rating- 0-3 A/DC
Scale- 0-3
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400LSLS - DC AMP 0-LEFT Rating- 0-5 A/DC Scale- 0-5 Legend- DC AMPERES - Product Image

Yokogawa 255400LSLS - DC AMP 0-LEFT

Rating- 0-5 A/DC
Scale- 0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400MTMT - DC AMP 0-LEFT Rating- 0-10 A/DC Scale- 0-10 Legend- DC AMPERES - Product Image

Yokogawa 255400MTMT - DC AMP 0-LEFT

Rating- 0-10 A/DC
Scale- 0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400NDND - DC AMP 0-LEFT Rating- 0-15 A/DC Scale- 0-15 Legend- DC AMPERES - Product Image

Yokogawa 255400NDND - DC AMP 0-LEFT

Rating- 0-15 A/DC
Scale- 0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400NGNG - DC AMP 0-LEFT Rating- 0-20 A/DC Scale- 0-20 Legend- DC AMPERES - Product Image

Yokogawa 255400NGNG - DC AMP 0-LEFT

Rating- 0-20 A/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400NLNL - DC AMP 0-LEFT Rating- 0-30 A/DC Scale- 0-30 Legend- DC AMPERES - Product Image

Yokogawa 255400NLNL - DC AMP 0-LEFT

Rating- 0-30 A/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255400NTNT - DC AMP 0-LEFT Rating- 0-50 A/DC Scale- 0-50 Legend- DC AMPERES - Product Image

Yokogawa 255400NTNT - DC AMP 0-LEFT

Rating- 0-50 A/DC
Scale- 0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401DRDR - DC AMP 0-CENTER Rating- 100-0-100 uA/DC Scale- 100-0-100 Legend- DC MICROAMPERES - Product Image

Yokogawa 255401DRDR - DC AMP 0-CENTER

Rating- 100-0-100 uA/DC
Scale- 100-0-100
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401EAEA - DC AMP 0-CENTER Rating- 200-0-200 uA/DC Scale- 200-0-200 Legend- DC MICROAMPERES - Product Image

Yokogawa 255401EAEA - DC AMP 0-CENTER

Rating- 200-0-200 uA/DC
Scale- 200-0-200
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401EMEM - DC AMP 0-CENTER Rating- 500-0-500 uA/DC Scale- 500-0-500 Legend- DC MICROAMPERES - Product Image

Yokogawa 255401EMEM - DC AMP 0-CENTER

Rating- 500-0-500 uA/DC
Scale- 500-0-500
Legend- DC MICROAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401FAFA - DC AMP 0-CENTER Rating- 1-0-1 mA/DC Scale- 1-0-1 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401FAFA - DC AMP 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 1-0-1
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401FNFN - DC AMP 0-CENTER Rating- 3-0-3 mA/DC Scale- 3-0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401FNFN - DC AMP 0-CENTER

Rating- 3-0-3 mA/DC
Scale- 3-0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401FXFX - DC AMP 0-CENTER Rating- 5-0-5 mA/DC Scale- 5-0-5 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401FXFX - DC AMP 0-CENTER

Rating- 5-0-5 mA/DC
Scale- 5-0-5
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401GZGZ - DC AMP 0-CENTER Rating- 10-0-10 mA/DC Scale- 10-0-10 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401GZGZ - DC AMP 0-CENTER

Rating- 10-0-10 mA/DC
Scale- 10-0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401HFHF - DC AMP 0-CENTER Rating- 20-0-20 mA/DC Scale- 20-0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401HFHF - DC AMP 0-CENTER

Rating- 20-0-20 mA/DC
Scale- 20-0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401HJHJ - DC AMP 0-CENTER Rating- 25-0-25 mA/DC Scale- 25-0-25 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401HJHJ - DC AMP 0-CENTER

Rating- 25-0-25 mA/DC
Scale- 25-0-25
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401HMHM - DC AMP 0-CENTER Rating- 30-0-30 mA/DC Scale- 30-0-30 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401HMHM - DC AMP 0-CENTER

Rating- 30-0-30 mA/DC
Scale- 30-0-30
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401HYHY - DC AMP 0-CENTER Rating- 50-0-50 mA/DC Scale- 50-0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401HYHY - DC AMP 0-CENTER

Rating- 50-0-50 mA/DC
Scale- 50-0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401JRJR - DC AMP 0-CENTER Rating- 100-0-100 mA/DC Scale- 100-0-100 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401JRJR - DC AMP 0-CENTER

Rating- 100-0-100 mA/DC
Scale- 100-0-100
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401JXJX - DC AMP 0-CENTER Rating- 150-0-150 mA/DC Scale- 150-0-150 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401JXJX - DC AMP 0-CENTER

Rating- 150-0-150 mA/DC
Scale- 150-0-150
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401KAKA - DC AMP 0-CENTER Rating- 200-0-200 mA/DC Scale- 200-0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401KAKA - DC AMP 0-CENTER

Rating- 200-0-200 mA/DC
Scale- 200-0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401KDKD - DC AMP 0-CENTER Rating- 250-0-250 mA/DC Scale- 250-0-250 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401KDKD - DC AMP 0-CENTER

Rating- 250-0-250 mA/DC
Scale- 250-0-250
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401KGKG - DC AMP 0-CENTER Rating- 300-0-300 mA/DC Scale- 300-0-300 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401KGKG - DC AMP 0-CENTER

Rating- 300-0-300 mA/DC
Scale- 300-0-300
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401KMKM - DC AMP 0-CENTER Rating- 500-0-500 mA/DC Scale- 500-0-500 Legend- DC MILLIAMPERES - Product Image

Yokogawa 255401KMKM - DC AMP 0-CENTER

Rating- 500-0-500 mA/DC
Scale- 500-0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401LALA - DC AMP 0-CENTER Rating- 1-0-1 A/DC Scale- 1-0-1 Legend- DC AMPERES - Product Image

Yokogawa 255401LALA - DC AMP 0-CENTER

Rating- 1-0-1 A/DC
Scale- 1-0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401LELE - DC AMP 0-CENTER Rating- 2-0-2 A/DC Scale- 2-0-2 Legend- DC AMPERES - Product Image

Yokogawa 255401LELE - DC AMP 0-CENTER

Rating- 2-0-2 A/DC
Scale- 2-0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401LSLS - DC AMP 0-CENTER Rating- 5-0-5 A/DC Scale- 5-0-5 Legend- DC AMPERES - Product Image

Yokogawa 255401LSLS - DC AMP 0-CENTER

Rating- 5-0-5 A/DC
Scale- 5-0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401MTMT - DC AMP 0-CENTER Rating- 10-0-10 A/DC Scale- 10-0-10 Legend- DC AMPERES - Product Image

Yokogawa 255401MTMT - DC AMP 0-CENTER

Rating- 10-0-10 A/DC
Scale- 10-0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401NDND - DC AMP 0-CENTER Rating- 15-0-15 A/DC Scale- 15-0-15 Legend- DC AMPERES - Product Image

Yokogawa 255401NDND - DC AMP 0-CENTER

Rating- 15-0-15 A/DC
Scale- 15-0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401NGNG - DC AMP 0-CENTER Rating- 20-0-20 A/DC Scale- 20-0-20 Legend- DC AMPERES - Product Image

Yokogawa 255401NGNG - DC AMP 0-CENTER

Rating- 20-0-20 A/DC
Scale- 20-0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401NLNL - DC AMP 0-CENTER Rating- 30-0-30 A/DC Scale- 30-0-30 Legend- DC AMPERES - Product Image

Yokogawa 255401NLNL - DC AMP 0-CENTER

Rating- 30-0-30 A/DC
Scale- 30-0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255401NTNT - DC AMP 0-CENTER Rating- 50-0-50 A/DC Scale- 50-0-50 Legend- DC AMPERES - Product Image

Yokogawa 255401NTNT - DC AMP 0-CENTER

Rating- 50-0-50 A/DC
Scale- 50-0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255404FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT Rating- 0-1 mA/DC Scale- 0-750 Legend- DC VOLTS - Product Image

Yokogawa 255404FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-LEFT

Rating- 0-1 mA/DC
Scale- 0-750
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 255405FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER Rating- 1-0-1 mA/DC Scale- 750-0-750 Legend- DC VOLTS - Product Image

Yokogawa 255405FASM - DC VOLTMETER - EXTERNAL RESISTOR 0-CENTER

Rating- 1-0-1 mA/DC
Scale- 750-0-750
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 251300DRDR8JCA - AC MICROAMPERES Rating- 0-100 uA/DC Scale- 0-10 Legend- PLI - Product Image

Yokogawa 251300DRDR8JCA - AC MICROAMPERES

Rating- 0-100 uA/DC
Scale- 0-10
Legend- PLI

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $100.00
Yokogawa 254200NLNLW0001 - DC AMMETER Rating- 0-30 A/DC Scale- 0-30 Legend- FIELD AMPS - Product Image

Yokogawa 254200NLNLW0001 - DC AMMETER

Rating- 0-30 A/DC
Scale- 0-30
Legend- FIELD AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $58.00
Yokogawa 250400HERXW0001 - DC AMMETER Rating- 4-20 mA/DC Scale- 0-300 Legend- AC AMPERES - Product Image

Yokogawa 250400HERXW0001 - DC AMMETER

Rating- 4-20 mA/DC
Scale- 0-300
Legend- AC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.00
Yokogawa 255400FAPNW0001 - DC AMMETER Rating- 0-1 mA/DC Scale- 0-120 Legend- PERCENT LIFT - Product Image

Yokogawa 255400FAPNW0001 - DC AMMETER

Rating- 0-1 mA/DC
Scale- 0-120
Legend- PERCENT LIFT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $82.60
Yokogawa 251400FASVW0001 - DC AMMETER Rating- 0-1 mA/DC Scale- 0-1200/0-60 Legend- AMPS - Product Image

Yokogawa 251400FASVW0001 - DC AMMETER

Rating- 0-1 mA/DC
Scale- 0-1200/0-60
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 254420MTUDW0001 - DC VOLTMETER Rating- 0-10 V/DC Scale- 0-3600 Legend- R.P.M. - Product Image

Yokogawa 254420MTUDW0001 - DC VOLTMETER

Rating- 0-10 V/DC
Scale- 0-3600
Legend- R.P.M.

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 254420MTPZW0001 - DC VOLTMETER Rating- 0-10 V/DC Scale- 0-150 Legend- PERCENT LOAD - Product Image

Yokogawa 254420MTPZW0001 - DC VOLTMETER

Rating- 0-10 V/DC
Scale- 0-150
Legend- PERCENT LOAD

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 251400FANWW0001 - DC AMMETER - 0 LEFT Rating- 0-1 mA/DC Scale- 0-60/0-12 Legend- AMPS - Product Image

Yokogawa 251400FANWW0001 - DC AMMETER - 0 LEFT

Rating- 0-1 mA/DC
Scale- 0-60/0-12
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $65.00
Yokogawa 250300FAPDW0002 - DC MILLIAMMETER - 0 LEFT Rating- 0-1 mA/DC Scale- 0-80 Legend- DC KILOVOLTS - Product Image

Yokogawa 250300FAPDW0002 - DC MILLIAMMETER - 0 LEFT

Rating- 0-1 mA/DC
Scale- 0-80
Legend- DC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 286111FAPKW0001 - DC AMMETER Rating- 0-1 mA/DC Scale- 0-100 Legend- No Legend - Product Image

Yokogawa 286111FAPKW0001 - DC AMMETER

Rating- 0-1 mA/DC
Scale- 0-100
Legend- No Legend

Manufacture: Yokogawa
Product Description: Notes- Drawing #180-95513-02

Product PDF
 
 Price: $69.00
Yokogawa 250300HEHE8KNO - DC AMP 0-LEFT Rating- 4-20 mA/DC Scale- 0-60 Legend- FPM - Product Image

Yokogawa 250300HEHE8KNO - DC AMP 0-LEFT

Rating- 4-20 mA/DC
Scale- 0-60
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.50
Yokogawa 250200EASJW0001 - DC AMP 0-LEFT Rating- 0-200 uA/DC Scale- 0-600/0-30/0-200 Legend- VOLTS / % - Product Image

Yokogawa 250200EASJW0001 - DC AMP 0-LEFT

Rating- 0-200 uA/DC
Scale- 0-600/0-30/0-200
Legend- VOLTS / %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.40
Yokogawa 250200HEPKW0002 - DC AMP 0-LEFT Rating- 4-20 mA/DC Scale- 0-100 Legend- FLAME SIGNAL - Product Image

Yokogawa 250200HEPKW0002 - DC AMP 0-LEFT

Rating- 4-20 mA/DC
Scale- 0-100
Legend- FLAME SIGNAL

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $74.50
Yokogawa 251300HFHF1JGR - DC AMP 0-LEFT Rating- 4-20 mA/DC Scale- 0-24 Legend- LBS/HR X 1000 - Product Image

Yokogawa 251300HFHF1JGR - DC AMP 0-LEFT

Rating- 4-20 mA/DC
Scale- 0-24
Legend- LBS/HR X 1000

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 185113FASS20001 - DC AMMETER Rating- 0-1 mA/DC Scale- 0-1000 Legend- AMPS - Product Image

Yokogawa 185113FASS20001 - DC AMMETER

Rating- 0-1 mA/DC
Scale- 0-1000
Legend- AMPS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 251424ECSJ - DC AMMETER - Rated:0-50 mV/DC, Scaled: 0-600 A/DC Rating- 0-50 mV/DC Scale- 0-600 Legend- DC AMPERES - Product Image

Yokogawa 251424ECSJ - DC AMMETER - Rated:0-50 mV/DC, Scaled: 0-600 A/DC

Rating- 0-50 mV/DC
Scale- 0-600
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $62.00
Yokogawa 251424ECSN - DC AMMETER - Rated:0-50 mV/DC, Scaled: 0-800 A/DC Rating- 0-50 mV/DC Scale- 0-800 Legend- DC AMPERES - Product Image

Yokogawa 251424ECSN - DC AMMETER - Rated:0-50 mV/DC, Scaled: 0-800 A/DC

Rating- 0-50 mV/DC
Scale- 0-800
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $62.00
Yokogawa 251424ECRL - DC AMMETER - Rated:0-50 mV/DC, Scaled: 0-800 A/DC Rating- 0-50 mV/DC Scale- 0-200 Legend- DC AMPERES - Product Image

Yokogawa 251424ECRL - DC AMMETER - Rated:0-50 mV/DC, Scaled: 0-800 A/DC

Rating- 0-50 mV/DC
Scale- 0-200
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $62.00
Yokogawa 251424ECNT - DC AMMETER - Rated:0-50 mV/DC, Scaled: 0-50 A/DC Rating- 0-50 mV/DC Scale- 0-50 Legend- DC AMPERES - Product Image

Yokogawa 251424ECNT - DC AMMETER - Rated:0-50 mV/DC, Scaled: 0-50 A/DC

Rating- 0-50 mV/DC
Scale- 0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $62.00
Yokogawa 250300HESCW0003 - TYPE 250 - DC MILLIAMMETER - SUPRESSED ZERO Rating- 4-20 mA/DC Scale- 450-0-450 Legend- DC AMPERES - Product Image

Yokogawa 250300HESCW0003 - TYPE 250 - DC MILLIAMMETER - SUPRESSED ZERO

Rating- 4-20 mA/DC
Scale- 450-0-450
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.44
Yokogawa 250300HEUJW0001 - TYPE 250 - DC MILLIAMMETER - SUPRESSED ZERO Rating- 4-20 mA/DC Scale- 0-5000 Legend- FPM - Product Image

Yokogawa 250300HEUJW0001 - TYPE 250 - DC MILLIAMMETER - SUPRESSED ZERO

Rating- 4-20 mA/DC
Scale- 0-5000
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.44
Yokogawa 250101HYHYW0001 - DC AMP 0 CENTER Rating- 60-0-60 mA/DC Scale- 60-0-60 Legend- DC MILLIAMPERES - Product Image

Yokogawa 250101HYHYW0001 - DC AMP 0 CENTER

Rating- 60-0-60 mA/DC
Scale- 60-0-60
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $66.00
Yokogawa 254330PDUAW0001 - TYPE 250 - AC RECTIFIED Rating- 0-68.7 V/AC Scale- 0-3400 Legend- WHEEL SPINDLE RPM x10 - Product Image

Yokogawa 254330PDUAW0001 - TYPE 250 - AC RECTIFIED

Rating- 0-68.7 V/AC
Scale- 0-3400
Legend- WHEEL SPINDLE RPM x10

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $75.00
Yokogawa 251200FNFN - DC AMP 0-LEFT Rating- 0-3 mA/DC Scale- 0-3 Legend- DC MILLIAMPERES - Product Image

Yokogawa 251200FNFN - DC AMP 0-LEFT

Rating- 0-3 mA/DC
Scale- 0-3
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $74.00
Yokogawa 250300DRPZW0001 - DC MICROAMMETER Rating- 0-100 uA/DC Scale- 0-150 Legend- PERCENT LOAD - Product Image

Yokogawa 250300DRPZW0001 - DC MICROAMMETER

Rating- 0-100 uA/DC
Scale- 0-150
Legend- PERCENT LOAD

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.00
Yokogawa 250300HEPKW0004 - DC AMP 0-LEFT Rating- 4-20 mA/DC Scale- 0-100 Legend- PERCENT SPEED - Product Image

Yokogawa 250300HEPKW0004 - DC AMP 0-LEFT

Rating- 4-20 mA/DC
Scale- 0-100
Legend- PERCENT SPEED

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $91.00
Yokogawa 260344RSRS - AC VOLT - ZERO LEFT Rating- 0-250 V/AC Scale- 0-250 Legend- AC VOLTS - Product Image

Yokogawa 260344RSRS - AC VOLT - ZERO LEFT

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Yokogawa
Product Description: The stylist series panel meters are available in window mount and surface mount styles and all meters meet ANSI specification C39.1. These meters are available in a variety of sizes, from 1.5 to 4.5in, and feature a 90 degree arc in the AC iron vane version and a 95 degree deflection in the taut band and pivot and jewel models.

SPECIFICATIONS
Accuracy: All DC and AC iron vane, +-2% of fullscale, AC rectifier type; +-3% of fullscale (60 Hz sinewave). Expanded scale voltmeters +-5% of fullscale. Special order DC with mirror back scale (DC only) 3-1/2 - 4-1/2in Available at +-1%.
ANSI Specification: All meters meet ANSI Specifications C-39.1 (See page 14 of Panel Meter Catalog PDF for exceptions.)
Overload: Voltmeters (AC + DC) - 50% momentary, 20% sustained. Ammeters (AC +DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 seconds with 1 minute interval between successive applications; sustained: 20% for six hours.

Scale Data:
AC IRON VANE
N/A for 1-1/2in model
2.15in for 2-1/2in model
2.70in for 3-1/2in model
3.80in for 4-1/2in model
TAUT BAND/PIVOT & JEWEL
1.66in for 1-1/2in model
2.29in for 2-1/2in model
2.85in for 3-1/2in model
4.01in for 4-1/2in model
ARC:
AC IRON VANE - 90%
TAUT BAND/PIVOT & JEWEL - 95%
Insulation Level: 2600V/1 min. (2-1/2in - 4-1/2in); 1500V/1 min. (1 1/2in)

Response Time:
3 seconds (Max.) - Microammeters
2 seconds (Max.) - All other DC ratings
2.5 seconds (Max.) - All AC ratings
Maximum 40% overshoot
Burden Data: AC Ammeter 5 amps at 60 Hz, 0.5VA, Max. .5 Power factor lagging, AC voltmeter - unity power factor.

Note:
Severe-duty meters are available to meet CUL or UL 1437 requirements in 2-1/2in - 4-1/2in sizes.

Three Mounting Types Available in Stylist Series: Rear Panel Window Mount, Front of Panel Surface Mount, Rear Panel Surface Mount Available with Optional Bezel

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters.Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect- AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $60.00
Yokogawa 250200KGKG - DC AMP 0-LEFT Rating- 0-200 mA/DC Scale- 0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 250200KGKG - DC AMP 0-LEFT

Rating- 0-200 mA/DC
Scale- 0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 251200KGKG - DC AMP 0-LEFT Rating- 0-200 mA/DC Scale- 0-200 Legend- DC MILLIAMPERES - Product Image

Yokogawa 251200KGKG - DC AMP 0-LEFT

Rating- 0-200 mA/DC
Scale- 0-200
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $74.00
Yokogawa 255300NGNG8JDY - DC AMP 0-LEFT With 3 Stud Mounting Rating- 0-20 A/DC Scale- 0-20 Legend- DC AMPERES - Product Image

Yokogawa 255300NGNG8JDY - DC AMP 0-LEFT
With 3 Stud Mounting

Rating- 0-20 A/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $62.00
Yokogawa 250200HFHF1JKC - Surpressed DC Ammeter Rating- 4-20 mA/DC Scale- 0-150 "Percent" Legend- - Product Image

Yokogawa 250200HFHF1JKC - Surpressed DC Ammeter

Rating- 4-20 mA/DC
Scale- 0-150 "Percent"
Legend-

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 251200NDNDW0001 - DC Ammeter Rating- 0-16 Scale- 0-16 Legend- DC Amperes - Product Image

Yokogawa 251200NDNDW0001 - DC Ammeter

Rating- 0-16
Scale- 0-16
Legend- DC Amperes

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $74.00
255300NGNG8JDY - DC AMP 0-LEFT With 3 Stud Mounting Rating- 0-20 A/DC Scale- 0-20 Legend- DC AMPERES - Product Image

255300NGNG8JDY - DC AMP 0-LEFT
With 3 Stud Mounting

Rating- 0-20 A/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description:

Product PDF
 
 Price: $62.00
Yokogawa 185114HYHY - DC MILLIAMPERES Rating- 50-0-50 mA/DC Scale- 50-0-50 Legend- DC MILLIAMPERES - Product Image

Yokogawa 185114HYHY - DC MILLIAMPERES

Rating- 50-0-50 mA/DC
Scale- 50-0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185114HYHY - DC MILLIAMPERES Rating- 20-0-20 mA/DC Scale- 20-0-20 Legend- DC MILLIAMPERES - Product Image

Yokogawa 185114HYHY - DC MILLIAMPERES

Rating- 20-0-20 mA/DC
Scale- 20-0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
SEW-ST9000HEPKW0008- DC AMP 0-LEFT Rating- 4-20 mA/DC Scale- 0-100 Legend- "%" - Product Image

SEW-ST9000HEPKW0008- DC AMP 0-LEFT

Rating- 4-20 mA/DC
Scale- 0-100
Legend- "%"

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.00