CA71-SP1 CA71 Calibrator with AccessoriesManufacture: Yokogawa Product Description: Signal source: DCV, DCA, Resistance, RTD, TC (10 kinds), Frequency, Pulse Measurement: DCV, DCA, ACV, Resistance, RTD, TC (10 kinds), Frequency, Pulse Features: Simultaneous signal source and measurement capacity, a wide array of useful functions, Easy operation, Online communication function Options: CA71/SP1 includes Communications cable, data logging softare, 120V power supply, magnetic backing instrument case, source/measure cables, NIST traceable certification.
Specifications:- Auto-Step Output Function n value sent automatically when n/m function selection is selected (two options: approximately 2.5 seconds/step or approximately 5 seconds/step)
- Sweep Functions Sweep time (two options: approximately 16 seconds or approximately 32 seconds)
- Memory Function 50 value sets (generated and measured values are stored as value sets with the same address (up to 50 value sets can be stored))
- Measuring Unit Maximum Input Voltage terminal: 300 V AC Current terminal: 120 mA DC
- Current Terminal Input Protection Fuses: 125 mA/250 V
- Measuring Unit Ground Voltage Maximum 300 V AC
- Measurement Display Updating Rate Approximately once per second
- Serial Interface Enabled when communication cable (RS232) is connected; sold separately as optional accessory
- Display Segmented LCD (Approx. 76 mm _ 48 mm)
- Backlight LED backlight; auto-off after one minute (from when LIGHT key is turned on)
- Power Supply Four AA alkaline batteries, or special AC adapter (sold separately)
- Battery Life Measurement off, output 5 V DC/10 kO or greater: Approximately 40 hours Simultaneous signal generation/measurement, output 5 V DC/10 kO or greater: Approximately 20 hoursSimultaneous signal generation/measurement, output 20 mA/5 V: Approximately 12 hours (using alkaline batteries, with backlight off)
- Auto-Power-Off Function Approx. 10 minutes (auto-power-off can be disabled through a DIP switch setting)
- Applicable Standard EN55011: 1998, Class B, Group 1
EN61326-1: 1997 + A1: 1998 IEC61010-1, IEC61010-2-31 - Insulation Resistance Across input terminal and output terminal, 500 V DC, 50 MO or greater
- Withstand Voltage Across input terminal and output terminal, 3.7 kVAC, for one minute
- Operating Temperature And Humidity Ranges 0 - 50 degrees C, 20 - 80% RH (no condensation)
- Storage Temperature And Humidity Ranges -20 - 50 degrees C, 90% RH or less (no condensation)
- External Dimensions Approx. 190 _ 120 _ 55 mm
- Weight Approx. 730 g (including batteries)
Part Number: CA71-SP1 |
|