Manufacture: Yokogawa Product Description: TX10 Series offers thermocouple thermometers that support K, J, E and T type thermocouples. There are three models available: 1-channel single-function, 1-channel multi-function, and 2-channel multi-function models.
TC Type Select the thermocouple type (K, J, E, and T) for the initial setting. (The type K is factory-set at shipment)
Operation Press and hold down the TC TYPE key while pressing the POWER key. The TX10 enters the thermocouple type selection mode, and each press of the TC TYPE key switches between the thermocouple types. Then accept the setting with the POWER key. (Make sure that the characters in the display have changed.)
Data Hold Press this key to hold the measured value.
Applications:
Temperature management in a refrigerated warehouse
Frozen food products quality control
Perishable foods quality control
Temperature management in production processes
Product temperature measurement test
Temperature checks in equipment maintenance
Temperature management for research and development
Specifications:
Number of Input channel 1
Measuring Range Type E: -200 to 700 degrees C (-328 to 1292 degrees F) Type J: -200 to 1000 degrees C (-328 to 1832 degrees F) Type K: -200 to 1372 degrees C (-328 to 2501.6 degrees F) Type T: -200 to 400 degrees C (-328 to 752 degrees F)
Resolution -200.0 degrees C to 199.9 degrees C: 0.1 degrees C 200 degrees C or above: 1 degrees C
Accuracy +200 degrees C or above, or when 1 degrees C resolution is set +-(0.2% of rdg + 1 degrees C) -100.0 degrees C to 199.9 degrees C +-(0.1% of rdg + 0.7 degrees C) -200.0 degrees C to -100.1 degrees C +-(0.1% of rdg + 1.0 degrees C)
Temperature Coefficient +- (0.015% of rdg +0.06 degrees C)/ degrees C
Approx. Measurement Interval 1 sec
Display Item HOLD, degrees C, ch A, TC type K, J, E, T, Battery alarm
Other Functions Auto power-off, battery alarm
Display LCD
Operating Temperature 0 to 50 degrees C
Humidity 80% RH (no condensation)
Power Requirements Two AA-size alkaline dry batteries (LR6)
Battery Life About 450 hours
Drip-proof Construction Conforms to IP54 (dust-proof and drip-proof requirements of IEC529)
Compliance with Standards EMC Standards EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1) EMS (immunity): EN50082-1;1997, EN61326;1998+A1
Approx. Height 151 mm
Approx. Width 56 mm
Approx. Depth 33 mm
Approx. External Weight 180 g
Supplied Accessories Two AA-size alkaline dry batteries (LR6) and instruction manual
Optional Accessories Extension Cable 5 m (2459 21)/10 m (2459 22) Soft case (930 12) Temperature Probes (for K type thermocouple) Rounded end probe (900 20, 900 21, 900 22) Needle probe (900 23, 900 24) Surface probe (900 30, 900 31, 900 32, 900 33) Bead TC (2459 07) Waterproof Cover (5-per package) (930 11)