1. WEIonline Shop >
  2. Product Categories >
  3. Analog Panel Meters >
  4. DC Voltage

Yokogawa 250320MTMT8JTN - DC VOLT O-LEFTRating- 0-10 V/DCScale- 0-20Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JTN - DC VOLT O-LEFT

Rating- 0-10 V/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JTS - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-20Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JTS - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JTT - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-800Legend- DC VOLTS - Product Image

Yokogawa 250320MTMT8JTT - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-800
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JTU - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-15Legend- PSI X 1000 - Product Image

Yokogawa 250320MTMT8JTU - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-15
Legend- PSI X 1000

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JTW - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- HZ - Product Image

Yokogawa 250320MTMT8JTW - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- HZ

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JTX - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- HERTZ - Product Image

Yokogawa 250320MTMT8JTX - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- HERTZ

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JTY - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-60Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JTY - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-60
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JTZ - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- DC VOLTS - Product Image

Yokogawa 250320MTMT8JTZ - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JUA - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-800Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JUA - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-800
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JUB - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JUB - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JUC - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-400Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JUC - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-400
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JUD - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JUD - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JUE - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-150Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JUE - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JUF - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-500Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JUF - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-500
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JUG - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8JUG - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JUH - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- DC VOLTS - Product Image

Yokogawa 250320MTMT8JUH - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JUM - DC VOLT 0-LEFTRating- 0-13.333 V/DCScale- 0-20Legend- FPM - Product Image

Yokogawa 250320MTMT8JUM - DC VOLT 0-LEFT

Rating- 0-13.333 V/DC
Scale- 0-20
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JUN - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- PSI - Product Image

Yokogawa 250320MTMT8JUN - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- PSI

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JUS - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- AC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250320MTMT8JUS - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- AC AMPERES W/ANSALDO LOGO

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $61.00
Yokogawa 250320MTMT8JUT - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-20Legend- AC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250320MTMT8JUT - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-20
Legend- AC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JUY - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-250Legend- PERCENT LOAD - Product Image

Yokogawa 250320MTMT8JUY - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-250
Legend- PERCENT LOAD

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JWA - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1Legend- DC AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTMT8JWA - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1
Legend- DC AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JWB - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-5Legend- DC AMPERES W SIEMENS LOGO - Product Image

Yokogawa 250320MTMT8JWB - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-5
Legend- DC AMPERES W SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JWD - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-20Legend- DC AMPERES W SIEMENS LOGO - Product Image

Yokogawa 250320MTMT8JWD - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-20
Legend- DC AMPERES W SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JWF - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-250Legend- DC VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250320MTMT8JWF - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-250
Legend- DC VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JWG - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-600Legend- DC VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250320MTMT8JWG - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-600
Legend- DC VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JWH - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-500Legend- DC AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTMT8JWH - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-500
Legend- DC AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JWK - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-2000Legend- DC AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTMT8JWK - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-2000
Legend- DC AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JXP - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- RPM - Product Image

Yokogawa 250320MTMT8JXP - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JXT - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- % - Product Image

Yokogawa 250320MTMT8JXT - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JXU - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-50Legend- DC AMPERES ANSALDO/ROSS H - Product Image

Yokogawa 250320MTMT8JXU - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-50
Legend- DC AMPERES ANSALDO/ROSS H

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JXX - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-5Legend- DC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250320MTMT8JXX - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-5
Legend- DC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JYE - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- AC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250320MTMT8JYE - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- AC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JYF - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-50Legend- AC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250320MTMT8JYF - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-50
Legend- AC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JYG - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-75Legend- AC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250320MTMT8JYG - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-75
Legend- AC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JYH - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-150Legend- AC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250320MTMT8JYH - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- AC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JYJ - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- AC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250320MTMT8JYJ - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- AC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JYK - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- DC VOLTS W/ DELTA DC POWE - Product Image

Yokogawa 250320MTMT8JYK - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC VOLTS W/ DELTA DC POWE

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JYU - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- RPM W/SIEMENS LOGO - Product Image

Yokogawa 250320MTMT8JYU - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- RPM W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZG - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-250Legend- % ADC W/ANSALDO LOGO - Product Image

Yokogawa 250320MTMT8JZG - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-250
Legend- % ADC W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZH - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- LINE SPEED-MPM W/ANSALDO - Product Image

Yokogawa 250320MTMT8JZH - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- LINE SPEED-MPM W/ANSALDO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZJ - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-150Legend- % ADC - Product Image

Yokogawa 250320MTMT8JZJ - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- % ADC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZK - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- DC VOLTS - Product Image

Yokogawa 250320MTMT8JZK - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZL - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-5000Legend- DC AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTMT8JZL - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-5000
Legend- DC AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZN - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-3000Legend- DC AMPERES /ANSALDO LOGP - Product Image

Yokogawa 250320MTMT8JZN - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-3000
Legend- DC AMPERES /ANSALDO LOGP

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZP - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-2000Legend- DC AMPERES /ANSALDO LOGP - Product Image

Yokogawa 250320MTMT8JZP - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-2000
Legend- DC AMPERES /ANSALDO LOGP

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZS - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-2500Legend- RPM - Product Image

Yokogawa 250320MTMT8JZS - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-2500
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZT - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-120Legend- % - Product Image

Yokogawa 250320MTMT8JZT - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-120
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.00
Yokogawa 250320MTMT8JZU - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- % - Product Image

Yokogawa 250320MTMT8JZU - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZW - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- % RPM - Product Image

Yokogawa 250320MTMT8JZW - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- % RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZY - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-30Legend- DC VOLTS - Product Image

Yokogawa 250320MTMT8JZY - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JZZ - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-3000Legend- FPM - Product Image

Yokogawa 250320MTMT8JZZ - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-3000
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KAB - DC VOLT 0-LEFTRating- 0-2/11 V/DCScale- 0-100Legend- % SPEED - Product Image

Yokogawa 250320MTMT8KAB - DC VOLT 0-LEFT

Rating- 0-2/11 V/DC
Scale- 0-100
Legend- % SPEED

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8KAC - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-6000Legend- FPM - Product Image

Yokogawa 250320MTMT8KAC - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-6000
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KAD - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-3000Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8KAD - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-3000
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KAF - DC VOLT 0-LEFTRating- 0-2/11 V/DCScale- 1-100Legend- % SPEED - Product Image

Yokogawa 250320MTMT8KAF - DC VOLT 0-LEFT

Rating- 0-2/11 V/DC
Scale- 1-100
Legend- % SPEED

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8KAT - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- PRECENT LOAD - Product Image

Yokogawa 250320MTMT8KAT - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- PRECENT LOAD

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KAX - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-30Legend- FPM - Product Image

Yokogawa 250320MTMT8KAX - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-30
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.00
Yokogawa 250320MTMT8KBB - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-150Legend- % LOAD - Product Image

Yokogawa 250320MTMT8KBB - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- % LOAD

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBC - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-4000/630Legend- SPINDLE RPM - Product Image

Yokogawa 250320MTMT8KBC - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-4000/630
Legend- SPINDLE RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8KBD - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-12Legend- FPM - Product Image

Yokogawa 250320MTMT8KBD - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-12
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBE - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- RPM - Product Image

Yokogawa 250320MTMT8KBE - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBK - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-5000Legend- RPM - Product Image

Yokogawa 250320MTMT8KBK - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-5000
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBL - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- % OPEN - Product Image

Yokogawa 250320MTMT8KBL - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- % OPEN

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBM - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-75Legend- MEGAWATTS - Product Image

Yokogawa 250320MTMT8KBM - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-75
Legend- MEGAWATTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBN - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 50-0-50Legend- MEGAVARS - Product Image

Yokogawa 250320MTMT8KBN - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 50-0-50
Legend- MEGAVARS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBP - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 50-0-50Legend- DC VOLTS - Product Image

Yokogawa 250320MTMT8KBP - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 50-0-50
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBR - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-300Legend- DC VOLTS - Product Image

Yokogawa 250320MTMT8KBR - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-300
Legend- DC VOLTS

Data subject to change without notice.

Dimensional Drawings

General Specifications

 

 
 Price: $61.00
Yokogawa 250320MTMT8KBS - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- DC AMPERES - Product Image

Yokogawa 250320MTMT8KBS - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBT - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-4000Legend- AC AMPERES - Product Image

Yokogawa 250320MTMT8KBT - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-4000
Legend- AC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBU - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-150Legend- DEGREES C - Product Image

Yokogawa 250320MTMT8KBU - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- DEGREES C

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00

Yokogawa 250320MTMT8KBW - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- -65 -60 -+60
Legend- HERTZ

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KBX - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-15Legend- AC KILOVOLTS - Product Image

Yokogawa 250320MTMT8KBX - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-15
Legend- AC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8KCA - 3 1/2 BIGLOOK DC VOLT METERRating- 0-10 V/DCScale- 0-10Legend- FPM - Product Image

Yokogawa 250320MTMT8KCA - 3 1/2 BIGLOOK DC VOLT METER

Rating- 0-10 V/DC
Scale- 0-10
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTNG8JSD - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-20Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTNG8JSD - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-20
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTNJ8JSE - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-25Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTNJ8JSE - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-25
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTNT8JSF - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-50Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTNT8JSF - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-50
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTPB8JSG - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-75Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTPB8JSG - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-75
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTPK8JSH - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTPK8JSH - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTPZ8JSJ - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-150Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTPZ8JSJ - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTRL8JSK - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTRL8JSK - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTRS8JSL - DC MILLIVOLT 0-LEFTRating- 0-10 V/DCScale- 0-250Legend- AMPERES W/SIEMENS - Product Image

Yokogawa 250320MTRS8JSL - DC MILLIVOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-250
Legend- AMPERES W/SIEMENS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.50
Yokogawa 250320MTSC8JSN - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-400Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTSC8JSN - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-400
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTSC8JTH - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-400Legend- VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250320MTSC8JTH - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-400
Legend- VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTSJ8JTD - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-600Legend- VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250320MTSJ8JTD - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-600
Legend- VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTSM8JSR - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-750Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250320MTSM8JSR - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-750
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTSS8 - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- DC VOLTS - Product Image

Yokogawa 250320MTSS8 - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTSS8JUL - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250320MTSS8JUL - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $71.00
Yokogawa 250320MTVA8JSS - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1Legend- KILOAMPERES W/SIEMENS LOG - Product Image

Yokogawa 250320MTVA8JSS - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1
Legend- KILOAMPERES W/SIEMENS LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTVE8JSU - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-2Legend- KILOAMPERES W/SIEMENS LOG - Product Image

Yokogawa 250320MTVE8JSU - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-2
Legend- KILOAMPERES W/SIEMENS LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MXMX8JPG - DC VOLT 0-LEFTRating- 0-12 V/DCScale- 0-12Legend- AC VOLTS - Product Image

Yokogawa 250320MXMX8JPG - DC VOLT 0-LEFT

Rating- 0-12 V/DC
Scale- 0-12
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MXMX8KBZ - DC VOLT 0-LEFTRating- 0-12 V/DCScale- 0-30Legend- RPM - Product Image

Yokogawa 250320MXMX8KBZ - DC VOLT 0-LEFT

Rating- 0-12 V/DC
Scale- 0-30
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.00
Yokogawa 250320MZMZ8JAU - DC VOLT 0-LEFTRating- 0-12.5 V/DCScale- 0-25Legend- FPM - Product Image

Yokogawa 250320MZMZ8JAU - DC VOLT 0-LEFT

Rating- 0-12.5 V/DC
Scale- 0-25
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MZMZ8JAW - DC VOLT 0-LEFTRating- 0-12.5 V/DCScale- 0-35Legend- FPM - Product Image

Yokogawa 250320MZMZ8JAW - DC VOLT 0-LEFT

Rating- 0-12.5 V/DC
Scale- 0-35
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320NDND - DC VOLT 0-LEFTRating- 0-15 V/DCScale- 0-15Legend- DC VOLTS - Product Image

Yokogawa 250320NDND - DC VOLT 0-LEFT

Rating- 0-15 V/DC
Scale- 0-15
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NDND8JYL - DC VOLT 0-LEFTRating- 0-15 V/DCScale- 0-15Legend- DC VOLTS/DELTA DC POWER - Product Image

Yokogawa 250320NDND8JYL - DC VOLT 0-LEFT

Rating- 0-15 V/DC
Scale- 0-15
Legend- DC VOLTS/DELTA DC POWER

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NDND8JZD - DC VOLT 0-LEFTRating- 0-15 V/DCScale- 0-100Legend- UNITS/MIN - Product Image

Yokogawa 250320NDND8JZD - DC VOLT 0-LEFT

Rating- 0-15 V/DC
Scale- 0-100
Legend- UNITS/MIN

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320NDND8KAY - DC VOLT 0-LEFTRating- 0-15 V/DCScale- 0-30Legend- FPM - Product Image

Yokogawa 250320NDND8KAY - DC VOLT 0-LEFT

Rating- 0-15 V/DC
Scale- 0-30
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NDND8KBY - DC VOLT 0-LEFTRating- 0-15 V/DCScale- 0-15Legend- RPM - Product Image

Yokogawa 250320NDND8KBY - DC VOLT 0-LEFT

Rating- 0-15 V/DC
Scale- 0-15
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.00
Yokogawa 250320NGNG - DC VOLT 0-LEFTRating- 0-20 V/DCScale- 0-20Legend- DC VOLTS - Product Image

Yokogawa 250320NGNG - DC VOLT 0-LEFT

Rating- 0-20 V/DC
Scale- 0-20
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NGNG8KBH-CSA - DC VOLT 0-LEFTRating- 0-19 V/DCScale- 0-20Legend- FPM - Product Image

Yokogawa 250320NGNG8KBH-CSA - DC VOLT 0-LEFT

Rating- 0-19 V/DC
Scale- 0-20
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320NJNJ - DC VOLT 0-LEFTRating- 0-25 V/DCScale- 0-25Legend- DC VOLTS - Product Image

Yokogawa 250320NJNJ - DC VOLT 0-LEFT

Rating- 0-25 V/DC
Scale- 0-25
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NLNL - DC VOLT 0-LEFTRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS - Product Image

Yokogawa 250320NLNL - DC VOLT 0-LEFT

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NLNL7JJC - 3 1/2 BL PMRating- 0-30 V/DCScale- 0-30Legend- VDC W/P-E LOGO - Product Image

Yokogawa 250320NLNL7JJC - 3 1/2 BL PM

Rating- 0-30 V/DC
Scale- 0-30
Legend- VDC W/P-E LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NLNL8JLS - DC VOLT 0-LEFT ULRating- 0-30 V/DCScale- 0-100Legend- % - Product Image

Yokogawa 250320NLNL8JLS - DC VOLT 0-LEFT UL

Rating- 0-30 V/DC
Scale- 0-100
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320NLNL8JPE - DC VOLT 0-LEFTRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS W/ASCO LOGO - Product Image

Yokogawa 250320NLNL8JPE - DC VOLT 0-LEFT

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS W/ASCO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NLNL8JUR - DC VOLT 0-LEFTRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS W/CON-SELECT LO - Product Image

Yokogawa 250320NLNL8JUR - DC VOLT 0-LEFT

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS W/CON-SELECT LO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NLNL8JYM - DC VOLT 0-LEFTRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS W/DELTA DC POWE - Product Image

Yokogawa 250320NLNL8JYM - DC VOLT 0-LEFT

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS W/DELTA DC POWE

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.00
Yokogawa 250320NLNL8JYN - DC VOLT 0-LEFTRating- 0-35 V/DCScale- 0-35Legend- DC VOLTS - Product Image

Yokogawa 250320NLNL8JYN - DC VOLT 0-LEFT

Rating- 0-35 V/DC
Scale- 0-35
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320NLNL8KBG - DC VOLT 0-LEFTRating- 0-30 V/DCScale- 0-30Legend- INCH BUILD-UP - Product Image

Yokogawa 250320NLNL8KBG - DC VOLT 0-LEFT

Rating- 0-30 V/DC
Scale- 0-30
Legend- INCH BUILD-UP

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320NPNP - DC VOLT 0-LEFTRating- 0-40 V/DCScale- 0-40Legend- DC VOLTS - Product Image

Yokogawa 250320NPNP - DC VOLT 0-LEFT

Rating- 0-40 V/DC
Scale- 0-40
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NPNP8JPT - DC VOLT 0-LEFTRating- 0-40 V/DCScale- 0-40Legend- DC VOLTS W/ZENITH CONTROL - Product Image

Yokogawa 250320NPNP8JPT - DC VOLT 0-LEFT

Rating- 0-40 V/DC
Scale- 0-40
Legend- DC VOLTS W/ZENITH CONTROL

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NTNT - DC VOLT 0-LEFTRating- 0-50 V/DCScale- 0-50Legend- DC VOLTS - Product Image

Yokogawa 250320NTNT - DC VOLT 0-LEFT

Rating- 0-50 V/DC
Scale- 0-50
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NTNT8JKL - 31/2 BIGLOOKRating- 0-50 V/DCScale- 0-50Legend- DC VOLTS W/WAUKESHA DRESS - Product Image

Yokogawa 250320NTNT8JKL - 31/2 BIGLOOK

Rating- 0-50 V/DC
Scale- 0-50
Legend- DC VOLTS W/WAUKESHA DRESS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NTNT8JNT - DC VOLT 0-LEFTRating- 0-50 V/DCScale- 0-50Legend- DC VOLTS W/TRILECTRON LOG - Product Image

Yokogawa 250320NTNT8JNT - DC VOLT 0-LEFT

Rating- 0-50 V/DC
Scale- 0-50
Legend- DC VOLTS W/TRILECTRON LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NTNT8JZE - DC VOLT 0-LEFTRating- 0-50 V/DCScale- 0-50Legend- DC VOLTS - Product Image

Yokogawa 250320NTNT8JZE - DC VOLT 0-LEFT

Rating- 0-50 V/DC
Scale- 0-50
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NTNT8KAK - DC VOLT 0-LEFTRating- 0-50 V/DCScale- 0-50Legend- POINT 8 LOGO - Product Image

Yokogawa 250320NTNT8KAK - DC VOLT 0-LEFT

Rating- 0-50 V/DC
Scale- 0-50
Legend- POINT 8 LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320NWNW - DC VOLT 0-LEFTRating- 0-60 V/DCScale- 0-60Legend- DC VOLTS - Product Image

Yokogawa 250320NWNW - DC VOLT 0-LEFT

Rating- 0-60 V/DC
Scale- 0-60
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320NWNW8KAH - DC VOLT 0-LEFTRating- 0-60 V/DCScale- 0-60Legend- DC VOLTS W/DELTA DC LOGO - Product Image

Yokogawa 250320NWNW8KAH - DC VOLT 0-LEFT

Rating- 0-60 V/DC
Scale- 0-60
Legend- DC VOLTS W/DELTA DC LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320NWPD - DC VOLT 0-LEFTRating- 0-60 V/DCScale- 0-80Legend- DC VOLTS - Product Image

Yokogawa 250320NWPD - DC VOLT 0-LEFT

Rating- 0-60 V/DC
Scale- 0-80
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320PBPB8JUK - 3 1/2 BL PANEL METERRating- 0-75 V/DCScale- 0-75Legend- DC VOLTS - Product Image

Yokogawa 250320PBPB8JUK - 3 1/2 BL PANEL METER

Rating- 0-75 V/DC
Scale- 0-75
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320PDPD - DC VOLT 0-LEFTRating- 0-80 V/DCScale- 0-80Legend- DC VOLTS - Product Image

Yokogawa 250320PDPD - DC VOLT 0-LEFT

Rating- 0-80 V/DC
Scale- 0-80
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PDPD8JPP - DC VOLT 0-LEFTRating- 0-80 V/DCScale- 0-120Legend- PERCENT - Product Image

Yokogawa 250320PDPD8JPP - DC VOLT 0-LEFT

Rating- 0-80 V/DC
Scale- 0-120
Legend- PERCENT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320PDPD8JUJ - DC VOLT 0 - LEFTRating- 0-80 V/DCScale- 0-80Legend- DC VOLTS - Product Image

Yokogawa 250320PDPD8JUJ - DC VOLT 0 - LEFT

Rating- 0-80 V/DC
Scale- 0-80
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PGPG8JUZ - DC VOLT 0-LEFTRating- 0-90 V/DCScale- 0-1800Legend- RPM - Product Image

Yokogawa 250320PGPG8JUZ - DC VOLT 0-LEFT

Rating- 0-90 V/DC
Scale- 0-1800
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250320PGPK8JPL - NBL TB PANEL METERRating- 0-90 V/DCScale- 0-100Legend- PERCENT - Product Image

Yokogawa 250320PGPK8JPL - NBL TB PANEL METER

Rating- 0-90 V/DC
Scale- 0-100
Legend- PERCENT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320PKPK - DC VOLT 0-LEFTRating- 0-100 V/DCScale- 0-100Legend- DC VOLTS - Product Image

Yokogawa 250320PKPK - DC VOLT 0-LEFT

Rating- 0-100 V/DC
Scale- 0-100
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PKPK8JPZ - DC VOLT 0-LEFTRating- 0-100 V/DCScale- 0-100Legend- DC VOLTS - Product Image

Yokogawa 250320PKPK8JPZ - DC VOLT 0-LEFT

Rating- 0-100 V/DC
Scale- 0-100
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PKPK8JXR - DC VOLT 0-LEFTRating- 0-100 V/DCScale- 0-10Legend- DC KILOVOLTS - Product Image

Yokogawa 250320PKPK8JXR - DC VOLT 0-LEFT

Rating- 0-100 V/DC
Scale- 0-10
Legend- DC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PRPR8KAN - DC VOLT 0-LEFTRating- 0-120 V/DCScale- 0-1200Legend- FPM - Product Image

Yokogawa 250320PRPR8KAN - DC VOLT 0-LEFT

Rating- 0-120 V/DC
Scale- 0-1200
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320PUPU8KBA - DC VOLT 0-LEFTRating- 0-130 V/DCScale- 0-510Legend- FPM - Product Image

Yokogawa 250320PUPU8KBA - DC VOLT 0-LEFT

Rating- 0-130 V/DC
Scale- 0-510
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320PUPU8KBJ - DC VOLT 0-LEFTRating- 0-130 V/DCScale- 0-9330Legend- MPS - Product Image

Yokogawa 250320PUPU8KBJ - DC VOLT 0-LEFT

Rating- 0-130 V/DC
Scale- 0-9330
Legend- MPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320PZPZ - DC VOLT 0-LEFTRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS - Product Image

Yokogawa 250320PZPZ - DC VOLT 0-LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PZPZ8JFP - AC VOLT I/VRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS - Product Image

Yokogawa 250320PZPZ8JFP - AC VOLT I/V

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250320PZPZ8JHA - DC VOLT 0-LEFTRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS W/POINT 8 LOGO - Product Image

Yokogawa 250320PZPZ8JHA - DC VOLT 0-LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS W/POINT 8 LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PZPZ8JNZ - DC VOLT 0-LEFTRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS - Product Image

Yokogawa 250320PZPZ8JNZ - DC VOLT 0-LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PZPZ8JPF - DC VOLT 0-LEFTRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS - Product Image

Yokogawa 250320PZPZ8JPF - DC VOLT 0-LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PZPZ8JPR - DC VOLT 0-LEFTRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS - Product Image

Yokogawa 250320PZPZ8JPR - DC VOLT 0-LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320PZPZ8JTM - DC VOLT 0-LEFTRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS W/PPP LOGO - Product Image

Yokogawa 250320PZPZ8JTM - DC VOLT 0-LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS W/PPP LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320RLRL - DC VOLT 0-LEFTRating- 0-200 V/DCScale- 0-200Legend- DC VOLTS - Product Image

Yokogawa 250320RLRL - DC VOLT 0-LEFT

Rating- 0-200 V/DC
Scale- 0-200
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250320RLRL8JXW - 3 1/2 BL PMRating- 0-200 V/DCScale- 0-5500Legend- FPM - Product Image

Yokogawa 250320RLRL8JXW - 3 1/2 BL PM

Rating- 0-200 V/DC
Scale- 0-5500
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320RLRL8JYW - 3 1/2 BL PMRating- 0-200 V/DCScale- 0-200Legend- DC VOLTS - Product Image

Yokogawa 250320RLRL8JYW - 3 1/2 BL PM

Rating- 0-200 V/DC
Scale- 0-200
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320RSRS - DC VOLT 0-LEFTRating- 0-250 V/DCScale- 0-250Legend- DC VOLTS - Product Image

Yokogawa 250320RSRS - DC VOLT 0-LEFT

Rating- 0-250 V/DC
Scale- 0-250
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250320RXRX - DC VOLT 0-LEFTRating- 0-300 V/DCScale- 0-300Legend- DC VOLTS - Product Image

Yokogawa 250320RXRX - DC VOLT 0-LEFT

Rating- 0-300 V/DC
Scale- 0-300
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250320RXRX8JXS - DC VOLT 0-LEFTRating- 0-300 V/DCScale- 0-300Legend- DC VOLTS W/ASCO LOGO - Product Image

Yokogawa 250320RXRX8JXS - DC VOLT 0-LEFT

Rating- 0-300 V/DC
Scale- 0-300
Legend- DC VOLTS W/ASCO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250320RXRX8JYC - DC VOLT 0-LEFT MTG OPT 1Rating- 0-300 V/DCScale- 0-300Legend- DC VOLTS W/CH LOGO - Product Image

Yokogawa 250320RXRX8JYC - DC VOLT 0-LEFT MTG OPT 1

Rating- 0-300 V/DC
Scale- 0-300
Legend- DC VOLTS W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250320RXRX8JZA - 3 1/2 BL DC VOLTMETERRating- 0-300 V/DCScale- 0-300Legend- DC VOLTS - Product Image

Yokogawa 250320RXRX8JZA - 3 1/2 BL DC VOLTMETER

Rating- 0-300 V/DC
Scale- 0-300
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250320SFSF - DC VOLT 0-LEFTRating- 0-500 V/DCScale- 0-500Legend- DC VOLTS - Product Image

Yokogawa 250320SFSF - DC VOLT 0-LEFT

Rating- 0-500 V/DC
Scale- 0-500
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.00
Yokogawa 250320SFSF8KCC - DC VOLT 0-LEFTRating- 0-500 V/DCScale- 0-500Legend- DC VOLTS - Product Image

Yokogawa 250320SFSF8KCC - DC VOLT 0-LEFT

Rating- 0-500 V/DC
Scale- 0-500
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320SJSJ - DC VOLT 0-LEFTRating- 0-600 V/DCScale- 0-600Legend- DC VOLTS - Product Image

Yokogawa 250320SJSJ - DC VOLT 0-LEFT

Rating- 0-600 V/DC
Scale- 0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320SJSJ8JPU - DC VOLT 0-LEFTRating- 0-600 V/DCScale- 0-600Legend- DC VOLTS - Product Image

Yokogawa 250320SJSJ8JPU - DC VOLT 0-LEFT

Rating- 0-600 V/DC
Scale- 0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $680.00
Yokogawa 250320SJSJ8JTF - DC VOLT 0-LEFTRating- 0-600 V/DCScale- 0-600Legend- VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250320SJSJ8JTF - DC VOLT 0-LEFT

Rating- 0-600 V/DC
Scale- 0-600
Legend- VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $91.00
Yokogawa 250320SJSJ8JYB - DC VOLT 0-LEFTRating- 0-600 V/DCScale- 0-600Legend- DC VOLTS - Product Image

Yokogawa 250320SJSJ8JYB - DC VOLT 0-LEFT

Rating- 0-600 V/DC
Scale- 0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320SMSM8JUU - DC VOLT 0-LEFTRating- 0-750 V/DCScale- 0-200Legend- % - Product Image

Yokogawa 250320SMSM8JUU - DC VOLT 0-LEFT

Rating- 0-750 V/DC
Scale- 0-200
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $91.00
Yokogawa 250320SMSM8KCB - DC VOLT 0-LEFTRating- 0-750 V/DCScale- 0-720Legend- DC VOLTS - Product Image

Yokogawa 250320SMSM8KCB - DC VOLT 0-LEFT

Rating- 0-750 V/DC
Scale- 0-720
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $91.00
Yokogawa 250320SNSN - DC VOLT 0-LEFTRating- 0-800 V/DCScale- 0-800Legend- DC VOLTS - Product Image

Yokogawa 250320SNSN - DC VOLT 0-LEFT

Rating- 0-800 V/DC
Scale- 0-800
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321LJLJ8JCA - DC VOLT 0-CENTERRating- 3-0-3 V/DCScale- 200-0-200Legend- % - Product Image

Yokogawa 250321LJLJ8JCA - DC VOLT 0-CENTER

Rating- 3-0-3 V/DC
Scale- 200-0-200
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321LJLJ8JGN - DC VOLT 0-CENTERRating- 3-0-3 V/DCScale- 700-0-700Legend- DC AMPERES - Product Image

Yokogawa 250321LJLJ8JGN - DC VOLT 0-CENTER

Rating- 3-0-3 V/DC
Scale- 700-0-700
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321LJLJ8JGP - DC VOLT 0-CENTERRating- 3-0-3 V/DCScale- 150-0-150Legend- % - Product Image

Yokogawa 250321LJLJ8JGP - DC VOLT 0-CENTER

Rating- 3-0-3 V/DC
Scale- 150-0-150
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321LJVB8JFX - DC VOLT 0-CENTERRating- 3-0-3 V/DCScale- 1.2-0-1.2Legend- DC KILOVOLTS - Product Image

Yokogawa 250321LJVB8JFX - DC VOLT 0-CENTER

Rating- 3-0-3 V/DC
Scale- 1.2-0-1.2
Legend- DC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321LJVB8JGS - DC VOLT 0-CENTERRating- 3-0-3 V/DCScale- 800-0-800Legend- DC AMPERES - Product Image

Yokogawa 250321LJVB8JGS - DC VOLT 0-CENTER

Rating- 3-0-3 V/DC
Scale- 800-0-800
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321LJVB8JGT - DC VOLT 0-CENTERRating- 3-0-3 V/DCScale- 900-0-900Legend- DC AMPERES - Product Image

Yokogawa 250321LJVB8JGT - DC VOLT 0-CENTER

Rating- 3-0-3 V/DC
Scale- 900-0-900
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321LJVB8JGU - DC VOLT 0-CENTERRating- 3-0-3 V/DCScale- 1100-0-1100Legend- DC AMPERES - Product Image

Yokogawa 250321LJVB8JGU - DC VOLT 0-CENTER

Rating- 3-0-3 V/DC
Scale- 1100-0-1100
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321LSLS - DC VOLT 0-CENTERRating- 5-0-5 V/DCScale- 5-0-5Legend- VDC - Product Image

Yokogawa 250321LSLS - DC VOLT 0-CENTER

Rating- 5-0-5 V/DC
Scale- 5-0-5
Legend- VDC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321LSLS8JDR - DC VOLT 0-CENTERRating- 5-0-5 V/DCScale- 1250-0-1250Legend- DC A - Product Image

Yokogawa 250321LSLS8JDR - DC VOLT 0-CENTER

Rating- 5-0-5 V/DC
Scale- 1250-0-1250
Legend- DC A

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321LSLS8JDW - DC VOLT 0-CENTERRating- 5-0-5 V/DCScale- 1000-0-1000Legend- DC AMPERES - Product Image

Yokogawa 250321LSLS8JDW - DC VOLT 0-CENTER

Rating- 5-0-5 V/DC
Scale- 1000-0-1000
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321LSLS8JDX - DC VOLT 0-CENTERRating- 5-0-5 V/DCScale- 500-0-500Legend- DC AMPERES - Product Image

Yokogawa 250321LSLS8JDX - DC VOLT 0-CENTER

Rating- 5-0-5 V/DC
Scale- 500-0-500
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321LSSV8JDU - DC VOLT 0-CENTERRating- 12-0-12 V/DCScale- 1200-0-1200Legend- VOLTS DC - Product Image

Yokogawa 250321LSSV8JDU - DC VOLT 0-CENTER

Rating- 12-0-12 V/DC
Scale- 1200-0-1200
Legend- VOLTS DC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321LWLW8JEF - DC VOLT 0-CENTERRating- 6-0-6 V/DCScale- 200-0-200Legend- % - Product Image

Yokogawa 250321LWLW8JEF - DC VOLT 0-CENTER

Rating- 6-0-6 V/DC
Scale- 200-0-200
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MJRL8JDN - DC VOLT 0-CENTERRating- 8-0-8 V/DCScale- 200-0-200Legend- % - Product Image

Yokogawa 250321MJRL8JDN - DC VOLT 0-CENTER

Rating- 8-0-8 V/DC
Scale- 200-0-200
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MJSF8 - DC VOLT 0-CENTERRating- 8-0-8 V/DCScale- 500-0-500Legend- DC VOLTS - Product Image

Yokogawa 250321MJSF8 - DC VOLT 0-CENTER

Rating- 8-0-8 V/DC
Scale- 500-0-500
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MJSJ8 - DC VOLT 0-CENTERRating- 8-0-8 V/DCScale- 600-0-600Legend- DC VOLTS - Product Image

Yokogawa 250321MJSJ8 - DC VOLT 0-CENTER

Rating- 8-0-8 V/DC
Scale- 600-0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MJSL8 - DC VOLT 0-CENTERRating- 8-0-8 V/DCScale- 700-0-700Legend- DC VOLTS - Product Image

Yokogawa 250321MJSL8 - DC VOLT 0-CENTER

Rating- 8-0-8 V/DC
Scale- 700-0-700
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTLA8JBM - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1-0-1Legend- BALANCE - Product Image

Yokogawa 250321MTLA8JBM - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1-0-1
Legend- BALANCE

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 10-0-10Legend- DC VOLTS - Product Image

Yokogawa 250321MTMT - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 10-0-10
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JBH - DC VOLTMETER - ZERO CENTERRating- 10-0-10 V/DCScale- 200-0-200Legend- % - Product Image

Yokogawa 250321MTMT8JBH - DC VOLTMETER - ZERO CENTER

Rating- 10-0-10 V/DC
Scale- 200-0-200
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JBW - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1600-0-1600Legend- AMPS - Product Image

Yokogawa 250321MTMT8JBW - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1600-0-1600
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JBX - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 2500-0-2500Legend- AMP - Product Image

Yokogawa 250321MTMT8JBX - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 2500-0-2500
Legend- AMP

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JBY - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 800-0-800Legend- DC AMPERES - Product Image

Yokogawa 250321MTMT8JBY - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 800-0-800
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JBZ - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1300-0-1300Legend- AMPERES - Product Image

Yokogawa 250321MTMT8JBZ - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1300-0-1300
Legend- AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JCB - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 3200-0-3200Legend- AMPS - Product Image

Yokogawa 250321MTMT8JCB - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 3200-0-3200
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50

Yokogawa 250321MTMT8JCD - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- -150-0-+150
Legend- TONS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50

Yokogawa 250321MTMT8JCE - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- -300-0-+300
Legend- TONS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JCF - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 15-0-15Legend- MA - Product Image

Yokogawa 250321MTMT8JCF - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 15-0-15
Legend- MA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JCG - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 200-0-200Legend- NONE - Product Image

Yokogawa 250321MTMT8JCG - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 200-0-200
Legend- NONE

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JDL - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1440-0-1440Legend- DC VOLTS - Product Image

Yokogawa 250321MTMT8JDL - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1440-0-1440
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JDM - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 100-0-100Legend- % - Product Image

Yokogawa 250321MTMT8JDM - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JDP - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 500-0-500Legend- RPM W/SIEMENS LOGO - Product Image

Yokogawa 250321MTMT8JDP - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 500-0-500
Legend- RPM W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JDS - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 100-0-100Legend- AMPS DC W/ANSALDO/ROSS HI - Product Image

Yokogawa 250321MTMT8JDS - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- AMPS DC W/ANSALDO/ROSS HI

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JDY - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1500-0-1500Legend- DC AMPERES W/ANSALDO/ROSS - Product Image

Yokogawa 250321MTMT8JDY - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1500-0-1500
Legend- DC AMPERES W/ANSALDO/ROSS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JDZ - DC VOLT O-CENTERRating- 10-0-10 V/DCScale- 2500-0-2500Legend- RPM W/ SIEMENT LOGO - Product Image

Yokogawa 250321MTMT8JDZ - DC VOLT O-CENTER

Rating- 10-0-10 V/DC
Scale- 2500-0-2500
Legend- RPM W/ SIEMENT LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JEA - DC VOLT O-CENTERRating- 10-0-10 V/DCScale- 1300-0-1300Legend- RPM W/SIEMENS LOGO - Product Image

Yokogawa 250321MTMT8JEA - DC VOLT O-CENTER

Rating- 10-0-10 V/DC
Scale- 1300-0-1300
Legend- RPM W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JEB - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 600-0-600Legend- DC AMPERES W/ANSALDO ROSS - Product Image

Yokogawa 250321MTMT8JEB - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 600-0-600
Legend- DC AMPERES W/ANSALDO ROSS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JEC - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 2500-0-2500Legend- DC AMPERES W/ANSALDO ROSS - Product Image

Yokogawa 250321MTMT8JEC - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 2500-0-2500
Legend- DC AMPERES W/ANSALDO ROSS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JEG - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 3500-0-3500Legend- RPM W/SIEMENS LOGO - Product Image

Yokogawa 250321MTMT8JEG - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 3500-0-3500
Legend- RPM W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JEH - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1100-0-1100Legend- RPM W/SIEMENS LOGO - Product Image

Yokogawa 250321MTMT8JEH - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1100-0-1100
Legend- RPM W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JEJ - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1000-0-1000Legend- RPM W/SIEMENS LOGO - Product Image

Yokogawa 250321MTMT8JEJ - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1000-0-1000
Legend- RPM W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTMT8JEK - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 5-0-5Legend- DC AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTMT8JEK - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 5-0-5
Legend- DC AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JEL - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 10-0-10Legend- DC AMPERES W/SIEMENS LOG - Product Image

Yokogawa 250321MTMT8JEL - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 10-0-10
Legend- DC AMPERES W/SIEMENS LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JEM - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 20-0-20Legend- DC AMPERES W/SIEMENS LOG - Product Image

Yokogawa 250321MTMT8JEM - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 20-0-20
Legend- DC AMPERES W/SIEMENS LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JEN - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 30-0-30Legend- DC AMPERES W/SIEMENS LOG - Product Image

Yokogawa 250321MTMT8JEN - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 30-0-30
Legend- DC AMPERES W/SIEMENS LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFB - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 200-0-200Legend- DC AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTMT8JFB - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 200-0-200
Legend- DC AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFC - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 300-0-300Legend- DC AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTMT8JFC - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 300-0-300
Legend- DC AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFG - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 2000-0-2000Legend- DC AMPERES ANSALDO/ROSS H - Product Image

Yokogawa 250321MTMT8JFG - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 2000-0-2000
Legend- DC AMPERES ANSALDO/ROSS H

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFH - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 600-0-600Legend- DC VOLTS ANSALDO/ROSS HIL - Product Image

Yokogawa 250321MTMT8JFH - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 600-0-600
Legend- DC VOLTS ANSALDO/ROSS HIL

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFJ - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 3000-0-3000Legend- DC AMPERES W/ANSALDO LOG - Product Image

Yokogawa 250321MTMT8JFJ - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 3000-0-3000
Legend- DC AMPERES W/ANSALDO LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFK - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 5000-0-5000Legend- DC AMPERES W/ANSALDO LOG - Product Image

Yokogawa 250321MTMT8JFK - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 5000-0-5000
Legend- DC AMPERES W/ANSALDO LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFL - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 7500-0-7500Legend- DC AMPERES W/ANSALDO LOG - Product Image

Yokogawa 250321MTMT8JFL - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 7500-0-7500
Legend- DC AMPERES W/ANSALDO LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFM - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1000-0-1000Legend- DC AMPERES W/ANSALDO LOG - Product Image

Yokogawa 250321MTMT8JFM - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1000-0-1000
Legend- DC AMPERES W/ANSALDO LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFN - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 750-0-750Legend- DC VOLTS W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JFN - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 750-0-750
Legend- DC VOLTS W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFP - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1000-0-1000Legend- DC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JFP - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1000-0-1000
Legend- DC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFR - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 500-0-500Legend- DC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JFR - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 500-0-500
Legend- DC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFS - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 6000-0-6000Legend- DC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JFS - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 6000-0-6000
Legend- DC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFT - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 300-0-300Legend- DC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JFT - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 300-0-300
Legend- DC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFY - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 800-0-800Legend- DC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JFY - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 800-0-800
Legend- DC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JFZ - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 400-0-400Legend- DC AMPERES W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JFZ - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 400-0-400
Legend- DC AMPERES W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGA - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 100-0-100Legend- % W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JGA - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- % W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGB - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 150%-0-150%Legend- RPM W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JGB - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 150%-0-150%
Legend- RPM W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGC - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 150%-0-150%Legend- ADC W/ANSALDO LOGO - Product Image

Yokogawa 250321MTMT8JGC - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 150%-0-150%
Legend- ADC W/ANSALDO LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGD - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 250-0-250Legend- ADC - Product Image

Yokogawa 250321MTMT8JGD - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 250-0-250
Legend- ADC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGE - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 750-0-750Legend- DC VOLTS W/ROSS HILL LOGO - Product Image

Yokogawa 250321MTMT8JGE - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 750-0-750
Legend- DC VOLTS W/ROSS HILL LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGF - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 800-0-800Legend- DC VOLTS W/ROSS HILL LOGO - Product Image

Yokogawa 250321MTMT8JGF - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 800-0-800
Legend- DC VOLTS W/ROSS HILL LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGH - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1000-0-1000Legend- DC AMPERES - Product Image

Yokogawa 250321MTMT8JGH - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1000-0-1000
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGJ - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 120-0-120Legend- % - Product Image

Yokogawa 250321MTMT8JGJ - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 120-0-120
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGK - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 100%-0-100%Legend- W/ANSALDO ROSS HILL LOGO - Product Image

Yokogawa 250321MTMT8JGK - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100%-0-100%
Legend- W/ANSALDO ROSS HILL LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGL - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 120%-0%-120%Legend- W/ANSALDO ROSS HILL - Product Image

Yokogawa 250321MTMT8JGL - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 120%-0%-120%
Legend- W/ANSALDO ROSS HILL

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGM - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1000-0-1000Legend- DC VOLT - Product Image

Yokogawa 250321MTMT8JGM - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1000-0-1000
Legend- DC VOLT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGR - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 600-0-600Legend- DC VOLTS - Product Image

Yokogawa 250321MTMT8JGR - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 600-0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGX - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1200-0-1200Legend- DC AMPERES - Product Image

Yokogawa 250321MTMT8JGX - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1200-0-1200
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JGY - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1500-0-1500Legend- DC AMPERES - Product Image

Yokogawa 250321MTMT8JGY - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1500-0-1500
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JHA - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1100-0-1100Legend- DC AMPERES - Product Image

Yokogawa 250321MTMT8JHA - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1100-0-1100
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTMT8JPT - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 700-0-700Legend- DC AMPERES - Product Image

Yokogawa 250321MTMT8JPT - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 700-0-700
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTNG8JCH - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 20-0-20Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTNG8JCH - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 20-0-20
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTNT8JCK - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 50-0-50Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTNT8JCK - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 50-0-50
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTPB8JCL - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 75-0-75Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTPB8JCL - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 75-0-75
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTPK8JCM - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 100-0-100Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTPK8JCM - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTPZ8JCN - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 150-0-150Legend- AMPERES LOGO=SIEMENS - Product Image

Yokogawa 250321MTPZ8JCN - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 150-0-150
Legend- AMPERES LOGO=SIEMENS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTRL8JCP - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 200-0-200Legend- AMPERES W/ SIEMENS LOGO - Product Image

Yokogawa 250321MTRL8JCP - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 200-0-200
Legend- AMPERES W/ SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTRX - 3 1/2 BIG LOOKRating- 10-0-10 V/DCScale- 300-0-300Legend- VOLTS DC - Product Image

Yokogawa 250321MTRX - 3 1/2 BIG LOOK

Rating- 10-0-10 V/DC
Scale- 300-0-300
Legend- VOLTS DC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTRX8JCS - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 300-0-300Legend- AMPERES W/ SIEMENS LOGO - Product Image

Yokogawa 250321MTRX8JCS - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 300-0-300
Legend- AMPERES W/ SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250321MTSC8JCT - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 400-0-400Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTSC8JCT - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 400-0-400
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTSF8JCU - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 500-0-500Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTSF8JCU - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 500-0-500
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTSJ8JDH - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 600-0-600Legend- VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250321MTSJ8JDH - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 600-0-600
Legend- VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTSJ8JGG - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 600-0-600Legend- DC VOLTS - Product Image

Yokogawa 250321MTSJ8JGG - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 600-0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTSM8JCW - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 750-0-750Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTSM8JCW - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 750-0-750
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTSM8JFW - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 750-0-750Legend- DC VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250321MTSM8JFW - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 750-0-750
Legend- DC VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTUJ8JFU - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 5000-0-5000Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250321MTUJ8JFU - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 5000-0-5000
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321MTVA8JCX - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1-0-1Legend- KILOAMPERES W/ SIEMENS LO - Product Image

Yokogawa 250321MTVA8JCX - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1-0-1
Legend- KILOAMPERES W/ SIEMENS LO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTVC8JCY - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 1.5-0-1.5Legend- KILOAMPERES W/SIEMENS LOG - Product Image

Yokogawa 250321MTVC8JCY - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 1.5-0-1.5
Legend- KILOAMPERES W/SIEMENS LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTVE8JCZ - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 2-0-2Legend- KILOAMPERES W/ SIEMENS LO - Product Image

Yokogawa 250321MTVE8JCZ - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 2-0-2
Legend- KILOAMPERES W/ SIEMENS LO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321MTVJ8JDB - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 3-0-3Legend- KILOAMPERES W/ SIEMENS LO - Product Image

Yokogawa 250321MTVJ8JDB - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 3-0-3
Legend- KILOAMPERES W/ SIEMENS LO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321NLNL - DC VOLT 0-CENTERRating- 30-0-30 V/DCScale- 30-0-30Legend- DC VOLTS - Product Image

Yokogawa 250321NLNL - DC VOLT 0-CENTER

Rating- 30-0-30 V/DC
Scale- 30-0-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321NTNT - DC VOLT 0-CENTERRating- 50-0-50 V/DCScale- 50-0-50Legend- DC VOLTS - Product Image

Yokogawa 250321NTNT - DC VOLT 0-CENTER

Rating- 50-0-50 V/DC
Scale- 50-0-50
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321NTNT8JGZ - DC VOLT 0-CENTERRating- 50-0-50 V/DCScale- 50-0-100Legend- DC VOLTS - Product Image

Yokogawa 250321NTNT8JGZ - DC VOLT 0-CENTER

Rating- 50-0-50 V/DC
Scale- 50-0-100
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321PBPB8JEE - DC VOLT 0-CENTERRating- 75-0-75 V/DCScale- 75-0-75Legend- DC VOLTS - Product Image

Yokogawa 250321PBPB8JEE - DC VOLT 0-CENTER

Rating- 75-0-75 V/DC
Scale- 75-0-75
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321PDPD - DC VOLT 0-CENTERRating- 80-0-80 V/DCScale- 80-0-80Legend- DC VOLTS - Product Image

Yokogawa 250321PDPD - DC VOLT 0-CENTER

Rating- 80-0-80 V/DC
Scale- 80-0-80
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321PDPD8JED - DC VOLT 0-CENTERRating- 80-0-80 V/DCScale- 450-0-450Legend- FPM - Product Image

Yokogawa 250321PDPD8JED - DC VOLT 0-CENTER

Rating- 80-0-80 V/DC
Scale- 450-0-450
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321PZPZ - DC VOLT 0-CENTERRating- 150-0-150 V/DCScale- 150-0-150Legend- DC VOLTS - Product Image

Yokogawa 250321PZPZ - DC VOLT 0-CENTER

Rating- 150-0-150 V/DC
Scale- 150-0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321RXRX - DC VOLT 0-CENTERRating- 300-0-300 V/DCScale- 300-0-300Legend- DC VOLTS - Product Image

Yokogawa 250321RXRX - DC VOLT 0-CENTER

Rating- 300-0-300 V/DC
Scale- 300-0-300
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321RXRX8JDJ - DC VOLT 0-CENTERRating- 300-0-300 V/DCScale- 300-0-300Legend- VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250321RXRX8JDJ - DC VOLT 0-CENTER

Rating- 300-0-300 V/DC
Scale- 300-0-300
Legend- VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250321SFSF - DC VOLT 0-CENTERRating- 500-0-500 V/DCScale- 500-0-500Legend- DC VOLTS - Product Image

Yokogawa 250321SFSF - DC VOLT 0-CENTER

Rating- 500-0-500 V/DC
Scale- 500-0-500
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321SFSF8JDT - DC VOLT 0-CENTERRating- 500-0-500 V/DCScale- 500-0-500Legend- DC VOLTS - Product Image

Yokogawa 250321SFSF8JDT - DC VOLT 0-CENTER

Rating- 500-0-500 V/DC
Scale- 500-0-500
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321SFSJ - DC VOLT 0-CENTERRating- 500-0-500 V/DCScale- 600-0-600Legend- DC VOLTS - Product Image

Yokogawa 250321SFSJ - DC VOLT 0-CENTER

Rating- 500-0-500 V/DC
Scale- 600-0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321SJSJ - DC VOLT 0-CENTERRating- 600-0-600 V/DCScale- 600-0-600Legend- DC VOLTS - Product Image

Yokogawa 250321SJSJ - DC VOLT 0-CENTER

Rating- 600-0-600 V/DC
Scale- 600-0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321SJSJ7JAN - 3 1/2 BL PMRating- 600-0-600 V/DCScale- 600-0-600Legend- VDC W/SIEMENS LOGO - Product Image

Yokogawa 250321SJSJ7JAN - 3 1/2 BL PM

Rating- 600-0-600 V/DC
Scale- 600-0-600
Legend- VDC W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $91.00
Yokogawa 250321SJSJ8JCC - DC VOLT 0-CENTERRating- 600-0-600 V/DCScale- 600-0-600Legend- DC VOLTS - Product Image

Yokogawa 250321SJSJ8JCC - DC VOLT 0-CENTER

Rating- 600-0-600 V/DC
Scale- 600-0-600
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250321SJSJ8JDK - DC VOLT 0-CENTERRating- 600-0-600 V/DCScale- 600-0-600Legend- VOLTS W/SIEMENS LOGO - Product Image

Yokogawa 250321SJSJ8JDK - DC VOLT 0-CENTER

Rating- 600-0-600 V/DC
Scale- 600-0-600
Legend- VOLTS W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $91.00
Yokogawa 250324ECEC7JAW - DC MILLIVOLT 0-LRating- 0-60 mV/DCScale- 0-100Legend- BLANK - Product Image

Yokogawa 250324ECEC7JAW - DC MILLIVOLT 0-L

Rating- 0-60 mV/DC
Scale- 0-100
Legend- BLANK

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $82.00
Yokogawa 250324ECEC8JAG - DC MILLIVOLT 0-LEFTRating- 0-0.1/1 A/DCScale- 0-100/1000Legend- DC MILLIAMPERES - Product Image

Yokogawa 250324ECEC8JAG - DC MILLIVOLT 0-LEFT

Rating- 0-0.1/1 A/DC
Scale- 0-100/1000
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECLA8 - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-1Legend- DC AMPERES - Product Image

Yokogawa 250324ECLA8 - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-1
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECLA8JHD - DC MILLIVOLT 0-CENTERRating- 0-50 mV/DCScale- 0-1Legend- DC AMPERES SHUNT EXTERNAL - Product Image

Yokogawa 250324ECLA8JHD - DC MILLIVOLT 0-CENTER

Rating- 0-50 mV/DC
Scale- 0-1
Legend- DC AMPERES SHUNT EXTERNAL

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECLC8JJH - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-1.5Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250324ECLC8JJH - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-1.5
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $82.00
Yokogawa 250324ECLE - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-2Legend- DC AMPERES - Product Image

Yokogawa 250324ECLE - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECLE8JHC - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-2Legend- DC AMPERES - Product Image

Yokogawa 250324ECLE8JHC - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-2
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $67.00
Yokogawa 250324ECLE8JJJ - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-2Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250324ECLE8JJJ - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-2
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECLJ8JHF - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-3Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250324ECLJ8JHF - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-3
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECLS - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-5Legend- DC AMPERES - Product Image

Yokogawa 250324ECLS - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECLS8JGZ - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-5Legend- DC AMPERES - Product Image

Yokogawa 250324ECLS8JGZ - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECLS8JHG - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-5Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250324ECLS8JHG - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-5
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECMT - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-10Legend- DC AMPERES - Product Image

Yokogawa 250324ECMT - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECMT8JHA - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-10Legend- DC AMPERES - Product Image

Yokogawa 250324ECMT8JHA - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-10
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $67.00
Yokogawa 250324ECMT8JHH - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-10Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250324ECMT8JHH - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-10
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECND - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-15Legend- DC AMPERES - Product Image

Yokogawa 250324ECND - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECND8JGY - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-15Legend- DC AMPERES - Product Image

Yokogawa 250324ECND8JGY - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-15
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECNG - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-20Legend- DC AMPERES - Product Image

Yokogawa 250324ECNG - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECNG8JJF - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-20Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250324ECNG8JJF - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-20
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.50
Yokogawa 250324ECNJ8 - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-25Legend- DC AMPERES - Product Image

Yokogawa 250324ECNJ8 - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-25
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECNJ8JHJ - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-25Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250324ECNJ8JHJ - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-25
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.50
Yokogawa 250324ECNL - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-30Legend- DC AMPERES - Product Image

Yokogawa 250324ECNL - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECNL8JJW - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-30Legend- DC AMPERES W/POINT 8 LOGO - Product Image

Yokogawa 250324ECNL8JJW - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-30
Legend- DC AMPERES W/POINT 8 LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECNT - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-50Legend- DC AMPERES - Product Image

Yokogawa 250324ECNT - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECNT8JHK - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-50Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250324ECNT8JHK - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-50
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.50
Yokogawa 250324ECPB - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-75Legend- DC AMPERES - Product Image

Yokogawa 250324ECPB - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-75
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPB8JJU - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-75Legend- DC AMPERES W/POINT 8 LOGO - Product Image

Yokogawa 250324ECPB8JJU - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-75
Legend- DC AMPERES W/POINT 8 LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPB8JKB - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-75Legend- DC AMPERES - Product Image

Yokogawa 250324ECPB8JKB - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-75
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPB8JKE - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-75Legend- DC AMPERES - Product Image

Yokogawa 250324ECPB8JKE - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-75
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPD8JEU - DC AMMETERRating- 0-50 mV/DCScale- 0-80Legend- DC AMPERES - Product Image

Yokogawa 250324ECPD8JEU - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-80
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPD8JKF - DC AMMETERRating- 0-50 mV/DCScale- 0-80Legend- DC AMPERES NO PAINT ON B - Product Image

Yokogawa 250324ECPD8JKF - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-80
Legend- DC AMPERES NO PAINT ON B

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPK - DC MILLIVOLT - Rated: 0-50 mV/DC, Scaled: 0-100 A/DCRating- 0-50 mV/DCScale- 0-100Legend- DC AMPERES - Product Image

Yokogawa 250324ECPK - DC MILLIVOLT - Rated: 0-50 mV/DC, Scaled: 0-100 A/DC

Rating- 0-50 mV/DC
Scale- 0-100
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPK8JGP - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-100Legend- DC AMPERES W/TRILECTRON L - Product Image

Yokogawa 250324ECPK8JGP - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-100
Legend- DC AMPERES W/TRILECTRON L

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPK8JHM - DC MILLIVOLTRating- 0-50 mV/DCScale- 0-100Legend- AMPERES W/SIEMENS LOGO - Product Image

Yokogawa 250324ECPK8JHM - DC MILLIVOLT

Rating- 0-50 mV/DC
Scale- 0-100
Legend- AMPERES W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.50
Yokogawa 250324ECPK8JJY - DC MILLIVOLTRating- 0-50 mV/DCScale- 0-100Legend- DC AMPERES - Product Image

Yokogawa 250324ECPK8JJY - DC MILLIVOLT

Rating- 0-50 mV/DC
Scale- 0-100
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.50
Yokogawa 250324ECPZ - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-150Legend- DC AMPERES - Product Image

Yokogawa 250324ECPZ - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-150
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPZ8JGT - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-150Legend- DC AMPERES - Product Image

Yokogawa 250324ECPZ8JGT - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-150
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECPZ8JKH - DC MILLIVOLTRating- 0-50 mV/DCScale- 0-150Legend- DC AMPERES - Product Image

Yokogawa 250324ECPZ8JKH - DC MILLIVOLT

Rating- 0-50 mV/DC
Scale- 0-150
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECRL - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-200Legend- DC AMPERES - Product Image

Yokogawa 250324ECRL - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-200
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECRL8JJG - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-200Legend- AMPERES - Product Image

Yokogawa 250324ECRL8JJG - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-200
Legend- AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250324ECRL8JJZ - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-200Legend- DC AMPERES - Product Image

Yokogawa 250324ECRL8JJZ - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-200
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $77.50
Yokogawa 250324ECRS - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-250Legend- DC AMPERES - Product Image

Yokogawa 250324ECRS - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-250
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00