1. WEIonline Shop >
  2. Product Categories >
  3. Analog Panel Meters >

DC Voltage

Yokogawa 162621ACAF2JEM - DC VOLTMETERRating- 0-25 V/DCScale- 0-60Legend- INCHES - Product Image

Yokogawa 162621ACAF2JEM - DC VOLTMETER

Rating- 0-25 V/DC
Scale- 0-60
Legend- INCHES

Manufacture: Yokogawa
Product Description: Notes- REPLACE W/ 254320NGNJW000?, 1000 OHMS/VOLT
 
 Price: $53.55
Yokogawa 250324ECEC7JDU - DC MILLIVOLTMETERRating- 0-50 mV/DCScale- 0-50Legend- DC MILLIVOLTS - Product Image

Yokogawa 250324ECEC7JDU - DC MILLIVOLTMETER

Rating- 0-50 mV/DC
Scale- 0-50
Legend- DC MILLIVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $106.90
Yokogawa 251320PKPK7JCL - SEE SPECIAL SCALES BOOKRating- 0-180VDC / 0-90VDCScale- SPECIAL # 6665K54P0347PZLegend-  - Product Image

Yokogawa 251320PKPK7JCL - SEE SPECIAL SCALES BOOK

Rating- 0-180VDC / 0-90VDC
Scale- SPECIAL # 6665K54P0347PZ
Legend-

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $107.10
Yokogawa 251325ECEC8JAJ - DC MILLIVOLTMETERRating- 50-0-50 mV/DCScale- 40 DIV. SCALE ONLYLegend- NONE - Product Image

Yokogawa 251325ECEC8JAJ - DC MILLIVOLTMETER

Rating- 50-0-50 mV/DC
Scale- 40 DIV. SCALE ONLY
Legend- NONE

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 261324ECSJ9JAG - DC AMMETERRating- 0-50 mV/DCScale- 0-600Legend- DC AMPERES - Product Image

Yokogawa 261324ECSJ9JAG - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-600
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: Notes- CUST. TAG # 2924-878-00, / NOTE: (NO DATA)
 
 Price: $53.55
Yokogawa 152011MTMT8KMY - NBL P&J PANEL METERRating- 0-10 V/DCScale- 0-100Legend- PERCENT SPEED - Product Image

Yokogawa 152011MTMT8KMY - NBL P&J PANEL METER

Rating- 0-10 V/DC
Scale- 0-100
Legend- PERCENT SPEED

Manufacture: Yokogawa
Product Description: Notes-
 
 Price: $73.50
Yokogawa 152011MTMT8KMZ - NBL PANEL METERRating- 0-10 V/DCScale- 0-100Legend- % SPEED - Product Image

Yokogawa 152011MTMT8KMZ - NBL PANEL METER

Rating- 0-10 V/DC
Scale- 0-100
Legend- % SPEED

Manufacture: Yokogawa
Product Description: Notes-
 
 Price: $70.50
Yokogawa 152011MTMT8KNA - NBL P&J PANEL METERRating- 0-10 V/DCScale- 0-60Legend- HERTZ - Product Image

Yokogawa 152011MTMT8KNA - NBL P&J PANEL METER

Rating- 0-10 V/DC
Scale- 0-60
Legend- HERTZ

Manufacture: Yokogawa
Product Description: Notes-
 
 Price: $73.50
Yokogawa 162011MTMT7MAX - 3 1/2 BL PANEL METERRating- 0-10 V/DCScale- 0-1800Legend- RPM - Product Image

Yokogawa 162011MTMT7MAX - 3 1/2 BL PANEL METER

Rating- 0-10 V/DC
Scale- 0-1800
Legend- RPM

Manufacture: Yokogawa
Product Description: Notes-
 
 Price: $79.00
Yokogawa 162011MTMT8MCM - NBL 3 1/2 PANEL METERRating- 0-10 V/DCScale- 0-1200Legend- RPM - Product Image

Yokogawa 162011MTMT8MCM - NBL 3 1/2 PANEL METER

Rating- 0-10 V/DC
Scale- 0-1200
Legend- RPM

Manufacture: Yokogawa
Product Description: Notes-
 
 Price: $79.00
Yokogawa 162011NTNT - DC VOLT 0-LEFTRating- 0-50 V/DCScale- 0-50Legend- DC VOLTS - Product Image

Yokogawa 162011NTNT - DC VOLT 0-LEFT

Rating- 0-50 V/DC
Scale- 0-50
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: Notes- Replcase w/ 254320NTNT
 
 Price: $58.00
Yokogawa 171121GBPB - DC MILLIVOLTS 0-LEFTRating- 0-100 mV/DCScale- 0-75Legend- DC AMPERES - Product Image

Yokogawa 171121GBPB - DC MILLIVOLTS 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-75
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: Notes- Replaced by: 254424GBPB
 
 Price: $60.00
Yokogawa 171121GBRL - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-200Legend- DC AMPERES - Product Image

Yokogawa 171121GBRL - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-200
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: Notes- Replaced by: 254424GBRL
 
 Price: $60.00
Yokogawa 185011MTMT - DC VOLTMETERRating- 0-10 V/DCScale- 0-10Legend- DC VOLTS - Product Image

Yokogawa 185011MTMT - DC VOLTMETER

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011MTMT7AAH - DC VOLTMETERRating- 1-5 V/DCScale- 0-100Legend- NONE - Product Image

Yokogawa 185011MTMT7AAH - DC VOLTMETER

Rating- 1-5 V/DC
Scale- 0-100
Legend- NONE

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011MTMT7JRE - VOLT-TYPE 185Rating- 0-10 V/DCScale- 0-100Legend- PERCENT - Product Image

Yokogawa 185011MTMT7JRE - VOLT-TYPE 185

Rating- 0-10 V/DC
Scale- 0-100
Legend- PERCENT

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011MTMT7JRG - VOLT-TYPE 185Rating- 0-10 V/DCScale- 0-100Legend- PERCENT - Product Image

Yokogawa 185011MTMT7JRG - VOLT-TYPE 185

Rating- 0-10 V/DC
Scale- 0-100
Legend- PERCENT

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011MTMT8JRK - DC VOLTMETER - TYPE 186 - HORIZONTALRating- 0-10 V/DCScale- 0-100Legend- LBS ACTUAL - Product Image

Yokogawa 185011MTMT8JRK - DC VOLTMETER - TYPE 186 - HORIZONTAL

Rating- 0-10 V/DC
Scale- 0-100
Legend- LBS ACTUAL

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011MTMT8JRL - DC VOLTMETER - TYPE 185 - HORIZONTALRating- 0-10 V/DCScale- 0-100Legend- LBS SETPOINT - Product Image

Yokogawa 185011MTMT8JRL - DC VOLTMETER - TYPE 185 - HORIZONTAL

Rating- 0-10 V/DC
Scale- 0-100
Legend- LBS SETPOINT

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011MTMT8JRM - DC VOLTMETER - TYPE 185 - HORIZONTALRating- 0-10 V/DCScale- 0-100Legend- LBS TENSION - Product Image

Yokogawa 185011MTMT8JRM - DC VOLTMETER - TYPE 185 - HORIZONTAL

Rating- 0-10 V/DC
Scale- 0-100
Legend- LBS TENSION

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011MTMT8JRN - DC VOLTMETER - TYPE 185 - HORIZONTALRating- 0-10 V/DCScale- 0-100Legend- % TAPER - Product Image

Yokogawa 185011MTMT8JRN - DC VOLTMETER - TYPE 185 - HORIZONTAL

Rating- 0-10 V/DC
Scale- 0-100
Legend- % TAPER

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011MTMT8JRS - DC VOLTMETERRating- 0-10 V/DCScale- 100-0-100Legend- % - Product Image

Yokogawa 185011MTMT8JRS - DC VOLTMETER

Rating- 0-10 V/DC
Scale- 100-0-100
Legend- %

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011MTMT8JRT - DC VOLTMETERRating- 0-10 V/DCScale- 0-10Legend- % - Product Image

Yokogawa 185011MTMT8JRT - DC VOLTMETER

Rating- 0-10 V/DC
Scale- 0-10
Legend- %

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011NDND - DC VOLTMETERRating- 0-15 V/DCScale- 0-15Legend- DC VOLTS - Product Image

Yokogawa 185011NDND - DC VOLTMETER

Rating- 0-15 V/DC
Scale- 0-15
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011NLNL - DC VOLTMETERRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS - Product Image

Yokogawa 185011NLNL - DC VOLTMETER

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011NTNT - DC VOLTMETERRating- 0-50 V/DCScale- 0-50Legend- DC VOLTS - Product Image

Yokogawa 185011NTNT - DC VOLTMETER

Rating- 0-50 V/DC
Scale- 0-50
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011NWNW - DC VOLTMETER - HORIZONTALRating- 0-60 V/DCScale- 0-60Legend- DC VOLTS - Product Image

Yokogawa 185011NWNW - DC VOLTMETER - HORIZONTAL

Rating- 0-60 V/DC
Scale- 0-60
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011NWNW8 - DC VOLTMETER EDGW - HORIZONTALRating- 0-60 V/DCScale- 0-60Legend- DC VOLTS - Product Image

Yokogawa 185011NWNW8 - DC VOLTMETER EDGW - HORIZONTAL

Rating- 0-60 V/DC
Scale- 0-60
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011NWNW8JRR - DC VOLTMETER EDGWISE - HORIZONTALRating- 0-60 V/DCScale- 0-60Legend- DC VOLTS - Product Image

Yokogawa 185011NWNW8JRR - DC VOLTMETER EDGWISE - HORIZONTAL

Rating- 0-60 V/DC
Scale- 0-60
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185011PKPK - DC VOLTMETER - Rated & Scaled: 0-100 V/DCRating- 0-100 V/DCScale- 0-100Legend- DC VOLTS - Product Image

Yokogawa 185011PKPK - DC VOLTMETER - Rated & Scaled: 0-100 V/DC

Rating- 0-100 V/DC
Scale- 0-100
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185012MTMT - DC VOLTMETERRating- 10-0-10 V/DCScale- 10-0-10Legend- DC VOLTS - Product Image

Yokogawa 185012MTMT - DC VOLTMETER

Rating- 10-0-10 V/DC
Scale- 10-0-10
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185012MTMT8JJB - DC VOLTMETER - HORIZONTALRating- 10-0-10 V/DCScale- 15-0-15Legend- MA - Product Image

Yokogawa 185012MTMT8JJB - DC VOLTMETER - HORIZONTAL

Rating- 10-0-10 V/DC
Scale- 15-0-15
Legend- MA

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00

Yokogawa 185012MTMT8JJC - DC VOLTMETER - HORIZONTAL

Rating- 10-0-10 V/DC
Scale- 10-0-10
Legend- DC VOLTS -+

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185012MTMT8JJE - DC VOLTMETER - HORIZONTALRating- 10-0-10 V/DCScale- 20-0-20Legend- DC MILLIAMPERES - Product Image

Yokogawa 185012MTMT8JJE - DC VOLTMETER - HORIZONTAL

Rating- 10-0-10 V/DC
Scale- 20-0-20
Legend- DC MILLIAMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185012MTMT8JJF - DC VOLTMETERRating- 10-0-10 V/DCScale- 10-0-10Legend- DC MILLIAMPERES - Product Image

Yokogawa 185012MTMT8JJF - DC VOLTMETER

Rating- 10-0-10 V/DC
Scale- 10-0-10
Legend- DC MILLIAMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185012MTMT8JJG - DC VOLTMETERRating- 10-0-10 V/DCScale- 100-0-100Legend- % - Product Image

Yokogawa 185012MTMT8JJG - DC VOLTMETER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- %

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185012NDND - DC VOLTMETERRating- 15-0-15 V/DCScale- 15-0-15Legend- DC VOLTS - Product Image

Yokogawa 185012NDND - DC VOLTMETER

Rating- 15-0-15 V/DC
Scale- 15-0-15
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185012NDND8JJD - DC VOLTMETERRating- 15-0-15 V/DCScale- 15-0-15Legend- DC VOLTS - Product Image

Yokogawa 185012NDND8JJD - DC VOLTMETER

Rating- 15-0-15 V/DC
Scale- 15-0-15
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185013MTMT - DC VOLTMETERRating- 0-10 V/DCScale- 0-10Legend- DC VOLTS - Product Image

Yokogawa 185013MTMT - DC VOLTMETER

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185013MTMT7AAE - DC VOLTMETERRating- 1-5 V/DCScale- 0-100Legend- NONE - Product Image

Yokogawa 185013MTMT7AAE - DC VOLTMETER

Rating- 1-5 V/DC
Scale- 0-100
Legend- NONE

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185013MTMT7AAG - DC VOLTMETERRating- 0-10 V/DCScale- NONELegend- NONE - Product Image

Yokogawa 185013MTMT7AAG - DC VOLTMETER

Rating- 0-10 V/DC
Scale- NONE
Legend- NONE

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185013MTMT7AAH - DC VOLTMETERRating- 1-5 V/DCScale- 0-100Legend- BLANK - Product Image

Yokogawa 185013MTMT7AAH - DC VOLTMETER

Rating- 1-5 V/DC
Scale- 0-100
Legend- BLANK

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185013MTMT7JTK - DC VOLTMETERRating- 0-10 V/DCScale- BLANKLegend- BLANK - Product Image

Yokogawa 185013MTMT7JTK - DC VOLTMETER

Rating- 0-10 V/DC
Scale- BLANK
Legend- BLANK

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185013MTMT8JTB - DC VOLTMETER (V)Rating- 0-10 V/DCScale- 0-100Legend- % - Product Image

Yokogawa 185013MTMT8JTB - DC VOLTMETER (V)

Rating- 0-10 V/DC
Scale- 0-100
Legend- %

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185013NLNL - DC VOLTMETERRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS - Product Image

Yokogawa 185013NLNL - DC VOLTMETER

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185013PKPK - DC VOLTMETERRating- 0-100 V/DCScale- 0-100Legend- DC VOLTS - Product Image

Yokogawa 185013PKPK - DC VOLTMETER

Rating- 0-100 V/DC
Scale- 0-100
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185013PZPZ - DC VOLTMETERRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS - Product Image

Yokogawa 185013PZPZ - DC VOLTMETER

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185014NDND7AAD - DC VOLTMETERRating- .4-0-.4 V/DCScale- SPECIALLegend- NONE - Product Image

Yokogawa 185014NDND7AAD - DC VOLTMETER

Rating- .4-0-.4 V/DC
Scale- SPECIAL
Legend- NONE

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185014NDND8JJY - DC VOLTMETERRating- 15-0-15 V/DCScale- 100-0-100Legend- PERCENT - Product Image

Yokogawa 185014NDND8JJY - DC VOLTMETER

Rating- 15-0-15 V/DC
Scale- 100-0-100
Legend- PERCENT

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185121ECNG - DC AMMETERRating- 0-50 mV/DCScale- 0-20Legend- DC AMPERES - Product Image

Yokogawa 185121ECNG - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185121ECNT - DC AMMETERRating- 0-50 mV/DCScale- 0-50Legend- DC AMPERES - Product Image

Yokogawa 185121ECNT - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-50
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185121ECPK - DC AMMETERRating- 0-50 mV/DCScale- 0-100Legend- DC AMPERES - Product Image

Yokogawa 185121ECPK - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-100
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185121ECRL - DC AMMETERRating- 0-50 mV/DCScale- 0-200Legend- DC AMPERES - Product Image

Yokogawa 185121ECRL - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-200
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185121ECRX - DC AMMETERRating- 0-50 mV/DCScale- 0-300Legend- DC AMPERES - Product Image

Yokogawa 185121ECRX - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-300
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185121ECSC - DC AMMETERRating- 0-50 mV/DCScale- 0-400Legend- DC AMPERES - Product Image

Yokogawa 185121ECSC - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-400
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185121ECSN - DC AMMETERRating- 0-50 mV/DCScale- 0-800Legend- DC AMPERES - Product Image

Yokogawa 185121ECSN - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-800
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185121ECSV - DC AMMETER EDGEWISERating- 0-50 mV/DCScale- 0-1200Legend- DC AMPERES - Product Image

Yokogawa 185121ECSV - DC AMMETER EDGEWISE

Rating- 0-50 mV/DC
Scale- 0-1200
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185123ECNL - DC AMMETERRating- 0-50 mV/DCScale- 0-30Legend- DC AMPERES - Product Image

Yokogawa 185123ECNL - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 185123ECNW - DC AMMETERRating- 0-50 mV/DCScale- 0-60Legend- DC AMPERES - Product Image

Yokogawa 185123ECNW - DC AMMETER

Rating- 0-50 mV/DC
Scale- 0-60
Legend- DC AMPERES

Manufacture: Yokogawa
Product Description: The edgewise family of panel meter products were designed to handle applications where panel space is at a premium. Both the 185 and 280 edgewise series meters may be mounted horizontally or vertically and meet ANSI C39.1. The Yokogawa line of edgewise meters are accurate to within +-2% of full scale in DC and +-3% for AC and come in a variety of sizes and ratings.

SPECIFICATIONS

Accuracy: DC Meters +-2% of full scale. AC rectifier type +-3% (60 Hertz sine wave at 25 degrees C)

Overload: Voltmeter - 50% momentary. 20% sustained. Ammeter - 900% momentary. 20% sustained

Scale Data: 53 degrees rotation. Length - 1.785

Insulation Level: 1800 VRMS Hi-pot

Response Time:
3 seconds (max.) for microammeters;
2 seconds (max.) for all other DC ratings; and
2.5 seconds (max.) for AC ratings
Overshoot: Maximum of 40%

Mounting: 3-stack mounted, 2-stack mounted, horizontal, and vertical meter with bezel

Dimensional Drawings

General Specifications
 
 Price: $300.00
Yokogawa 250120LSLS8JBG - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-100Legend- PERCENT - Product Image

Yokogawa 250120LSLS8JBG - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-100
Legend- PERCENT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250120LSLS8JBH - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-100Legend- % - Product Image

Yokogawa 250120LSLS8JBH - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-100
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120LSLS8JBJ - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 100-0-100Legend- % - Product Image

Yokogawa 250120LSLS8JBJ - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 100-0-100
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- DC VOLTS - Product Image

Yokogawa 250120MTMT - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250120MTMT8JAT - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-3500Legend- ADC - Product Image

Yokogawa 250120MTMT8JAT - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-3500
Legend- ADC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JAU - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1200Legend- AAC - Product Image

Yokogawa 250120MTMT8JAU - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1200
Legend- AAC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JAW - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1100Legend- VDCC - Product Image

Yokogawa 250120MTMT8JAW - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1100
Legend- VDCC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JAX - 250120MTMT8JAWRating- 0-10 V/DCScale- 0-15Legend- KVAC - Product Image

Yokogawa 250120MTMT8JAX - 250120MTMT8JAW

Rating- 0-10 V/DC
Scale- 0-15
Legend- KVAC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JAY - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-3.0Legend- MVA - Product Image

Yokogawa 250120MTMT8JAY - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-3.0
Legend- MVA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JAZ - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-2.5Legend- MW - Product Image

Yokogawa 250120MTMT8JAZ - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-2.5
Legend- MW

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JBA - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-600Legend- VAC - Product Image

Yokogawa 250120MTMT8JBA - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-600
Legend- VAC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JBB - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-3.0Legend- MVA - Product Image

Yokogawa 250120MTMT8JBB - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-3.0
Legend- MVA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JBC - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-2200Legend- VDC - Product Image

Yokogawa 250120MTMT8JBC - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-2200
Legend- VDC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JBD - DC VOLT 0-LEFTRating- 0-10 V/DCScale- -5.0-0-5.0Legend- MVA - Product Image

Yokogawa 250120MTMT8JBD - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- -5.0-0-5.0
Legend- MVA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00

Yokogawa 250120MTMT8JBE - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- -0-1-+0
Legend- POWER FACTOR

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120MTMT8JBF - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1200Legend- DC VOLTS - Product Image

Yokogawa 250120MTMT8JBF - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1200
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120NDND - DC VOLT 0-LEFTRating- 0-15 V/DCScale- 0-15Legend- DC VOLTS - Product Image

Yokogawa 250120NDND - DC VOLT 0-LEFT

Rating- 0-15 V/DC
Scale- 0-15
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250120NGNG - DC VOLT 0-LEFTRating- 0-20 V/DCScale- 0-20Legend- DC VOLTS - Product Image

Yokogawa 250120NGNG - DC VOLT 0-LEFT

Rating- 0-20 V/DC
Scale- 0-20
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250120NLNL - DC VOLT 0-LEFTRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS - Product Image

Yokogawa 250120NLNL - DC VOLT 0-LEFT

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250120NLNL8JBK - 1 1/2 BL PMRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS - Product Image

Yokogawa 250120NLNL8JBK - 1 1/2 BL PM

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120NTNT - DC VOLT 0-LEFTRating- 0-50 V/DCScale- 0-50Legend- DC VOLTS - Product Image

Yokogawa 250120NTNT - DC VOLT 0-LEFT

Rating- 0-50 V/DC
Scale- 0-50
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250120NWNW8JBL - 1 1/2 BL PMRating- 0-60 V/DCScale- 0-60Legend- DC VOLTS - Product Image

Yokogawa 250120NWNW8JBL - 1 1/2 BL PM

Rating- 0-60 V/DC
Scale- 0-60
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250120PKPK - DC VOLT 0-LEFTRating- 0-100 V/DCScale- 0-100Legend- DC VOLTS - Product Image

Yokogawa 250120PKPK - DC VOLT 0-LEFT

Rating- 0-100 V/DC
Scale- 0-100
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250120PKPK8JAS - DC VOLT 0-LEFT - SILICON DAMRating- 0-100 V/DCScale- 0-100Legend- DC VOLTS - Product Image

Yokogawa 250120PKPK8JAS - DC VOLT 0-LEFT - SILICON DAM

Rating- 0-100 V/DC
Scale- 0-100
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $103.00
Yokogawa 250120PZPZ - DC VOLT 0-LEFTRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS - Product Image

Yokogawa 250120PZPZ - DC VOLT 0-LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250120RSRS - DC VOLT 0-LEFTRating- 0-250 V/DCScale- 0-250Legend- DC VOLTS - Product Image

Yokogawa 250120RSRS - DC VOLT 0-LEFT

Rating- 0-250 V/DC
Scale- 0-250
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250120RXRX - DC VOLT 0-LEFTRating- 0-300 V/DCScale- 0-300Legend- DC VOLTS - Product Image

Yokogawa 250120RXRX - DC VOLT 0-LEFT

Rating- 0-300 V/DC
Scale- 0-300
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250121MTMT - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 10-0-10Legend- DC VOLTS - Product Image

Yokogawa 250121MTMT - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 10-0-10
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250121MTMT8JAW - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 100-0-100Legend- PERCENT - Product Image

Yokogawa 250121MTMT8JAW - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- PERCENT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250121MTMT8JAX - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 100-0-100Legend- PERCENT W/SIEMENS LOGO - Product Image

Yokogawa 250121MTMT8JAX - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- PERCENT W/SIEMENS LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250121NDND - DC VOLT 0-CENTERRating- 15-0-15 V/DCScale- 15-0-15Legend- DC VOLTS - Product Image

Yokogawa 250121NDND - DC VOLT 0-CENTER

Rating- 15-0-15 V/DC
Scale- 15-0-15
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250121NDND7JAG - DC VOLT 0-CENTERRating- 15-0-15 V/DCScale- 15-0-15Legend- DC VOLTS - Product Image

Yokogawa 250121NDND7JAG - DC VOLT 0-CENTER

Rating- 15-0-15 V/DC
Scale- 15-0-15
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $78.00
Yokogawa 250121NLNL - DC VOLT 0-CENTERRating- 30-0-30 V/DCScale- 30-0-30Legend- DC VOLTS - Product Image

Yokogawa 250121NLNL - DC VOLT 0-CENTER

Rating- 30-0-30 V/DC
Scale- 30-0-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250121NTNT - DC VOLT 0-CENTERRating- 50-0-50 V/DCScale- 50-0-50Legend- DC VOLTS - Product Image

Yokogawa 250121NTNT - DC VOLT 0-CENTER

Rating- 50-0-50 V/DC
Scale- 50-0-50
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $63.00
Yokogawa 250124ECNL - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-30Legend- DC AMPERES - Product Image

Yokogawa 250124ECNL - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250124ECNT - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-50Legend- DC AMPERES - Product Image

Yokogawa 250124ECNT - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250124ECNT8JAD - DC MILLIVOLTRating- 0-25 mV/DCScale- 0-50Legend- BLANK - Product Image

Yokogawa 250124ECNT8JAD - DC MILLIVOLT

Rating- 0-25 mV/DC
Scale- 0-50
Legend- BLANK

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $102.00
Yokogawa 250124ECPB - DC MILLIVOLT 0-LEFTRating- 0-50 mV/DCScale- 0-75Legend- DC AMPERES - Product Image

Yokogawa 250124ECPB - DC MILLIVOLT 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-75
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250124ECPK - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-100Legend- DC AMPERES - Product Image

Yokogawa 250124ECPK - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-100
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250124ECPZ - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-150Legend- DC AMPERES - Product Image

Yokogawa 250124ECPZ - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-150
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250124ECRX - DC MILLIVOLT 0-LRating- 0-50 mV/DCScale- 0-300Legend- DC AMPERES - Product Image

Yokogawa 250124ECRX - DC MILLIVOLT 0-L

Rating- 0-50 mV/DC
Scale- 0-300
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250124GBPB - DC MILLIVOLT 0-LEFTRating- 0-100 mV/DCScale- 0-75Legend- DC AMPERES - Product Image

Yokogawa 250124GBPB - DC MILLIVOLT 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-75
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250125ECSJ - NBL, DC PANEL AMMETERRating- 50-0-50 mV/DCScale- 600-0-600Legend- DC AMPERES - Product Image

Yokogawa 250125ECSJ - NBL, DC PANEL AMMETER

Rating- 50-0-50 mV/DC
Scale- 600-0-600
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250125GBNT - DC MILLIVOLT 0-CENTERRating- 100-0-100 mV/DCScale- 50-0-50Legend- DC AMPERES - Product Image

Yokogawa 250125GBNT - DC MILLIVOLT 0-CENTER

Rating- 100-0-100 mV/DC
Scale- 50-0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250125GBPB - DC MILLIVOLT 0-CENTERRating- 100-0-100 mV/DCScale- 75-0-75Legend- DC AMPERES - Product Image

Yokogawa 250125GBPB - DC MILLIVOLT 0-CENTER

Rating- 100-0-100 mV/DC
Scale- 75-0-75
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250125GBSC - DC MILLIVOLT 0-CRating- 100-0-100 mV/DCScale- 400-0-400Legend- DC AMPERES - Product Image

Yokogawa 250125GBSC - DC MILLIVOLT 0-C

Rating- 100-0-100 mV/DC
Scale- 400-0-400
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $64.00
Yokogawa 250220LJLJ8JFG - DC VOLT 0 LEFTRating- 0-3 V/DCScale- 0-30Legend- DC AMPERES - Product Image

Yokogawa 250220LJLJ8JFG - DC VOLT 0 LEFT

Rating- 0-3 V/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220LSLS - DC VOLT 0 LEFTRating- 0-5 V/DCScale- 0-5Legend- DC VOLTS - Product Image

Yokogawa 250220LSLS - DC VOLT 0 LEFT

Rating- 0-5 V/DC
Scale- 0-5
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220LSLS8JEL - DC VOLT 0 LEFTRating- 0-5 V/DCScale- 0-72Legend- INCHES - Product Image

Yokogawa 250220LSLS8JEL - DC VOLT 0 LEFT

Rating- 0-5 V/DC
Scale- 0-72
Legend- INCHES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220MTMT - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-10Legend- DC VOLTS - Product Image

Yokogawa 250220MTMT - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT7JEE - 2 1/2 BL DC VOLTMETERRating- 0-10 V/DCScale- 0-60Legend- HZ - Product Image

Yokogawa 250220MTMT7JEE - 2 1/2 BL DC VOLTMETER

Rating- 0-10 V/DC
Scale- 0-60
Legend- HZ

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JDA - DC V #2A95684H20 2 STUDS ULRating- 0-10 V/DCScale- 0-100Legend- % W/CH LOGO NO SILVER PAI - Product Image

Yokogawa 250220MTMT8JDA - DC V #2A95684H20 2 STUDS UL

Rating- 0-10 V/DC
Scale- 0-100
Legend- % W/CH LOGO NO SILVER PAI

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220MTMT8JDG - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-10Legend- DC VOLTS - Product Image

Yokogawa 250220MTMT8JDG - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JDZ - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- LBS - Product Image

Yokogawa 250220MTMT8JDZ - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- LBS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220MTMT8JEB - 2 1/2 NBL DC VOLTMETERRating- 0-10 V/DCScale- 0-4000Legend- ADC W/WESTINGHOUSE LOGO - Product Image

Yokogawa 250220MTMT8JEB - 2 1/2 NBL DC VOLTMETER

Rating- 0-10 V/DC
Scale- 0-4000
Legend- ADC W/WESTINGHOUSE LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220MTMT8JEF - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-40Legend- AMPS - Product Image

Yokogawa 250220MTMT8JEF - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-40
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220MTMT8JEG - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-500Legend- VOLTS - Product Image

Yokogawa 250220MTMT8JEG - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-500
Legend- VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220MTMT8JEH - DC VOLTS 0-LEFTRating- 0-10 V/DCScale- 0-150Legend- % LOAD - Product Image

Yokogawa 250220MTMT8JEH - DC VOLTS 0-LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- % LOAD

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JEK - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-4000Legend- AMPS - Product Image

Yokogawa 250220MTMT8JEK - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-4000
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JEM - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-80Legend- LBS - Product Image

Yokogawa 250220MTMT8JEM - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-80
Legend- LBS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JEN - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-30Legend- FPM - Product Image

Yokogawa 250220MTMT8JEN - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-30
Legend- FPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JER - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-150Legend- AMPS - Product Image

Yokogawa 250220MTMT8JER - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JES - DC VOLT 0 LEFT MTG OPT 1Rating- 0-10 V/DCScale- 0-1840Legend- DC AMPERES W/CH LOGO - Product Image

Yokogawa 250220MTMT8JES - DC VOLT 0 LEFT MTG OPT 1

Rating- 0-10 V/DC
Scale- 0-1840
Legend- DC AMPERES W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $65.00
Yokogawa 250220MTMT8JET - DC VOLT 0 LEFT MTG OPT 1Rating- 0-10 V/DCScale- 0-650Legend- DC VOLTS W/CH LOGO - Product Image

Yokogawa 250220MTMT8JET - DC VOLT 0 LEFT MTG OPT 1

Rating- 0-10 V/DC
Scale- 0-650
Legend- DC VOLTS W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JEU - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-100Legend- % - Product Image

Yokogawa 250220MTMT8JEU - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JEY - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-100Legend- INCHES OF PAPER - Product Image

Yokogawa 250220MTMT8JEY - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- INCHES OF PAPER

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $85.00
Yokogawa 250220MTMT8JEZ - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-1800Legend- RPM - Product Image

Yokogawa 250220MTMT8JEZ - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-1800
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $85.00
Yokogawa 250220MTMT8JFA - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-700Legend-  - Product Image

Yokogawa 250220MTMT8JFA - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-700
Legend-

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JFE - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-100Legend- PERCENT RPM - Product Image

Yokogawa 250220MTMT8JFE - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- PERCENT RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JFH - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-1500Legend- DC AMPERES W/CH LOGO - Product Image

Yokogawa 250220MTMT8JFH - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-1500
Legend- DC AMPERES W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JFK - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 60/600 -0 -60/600Legend- RPM/MIN - Product Image

Yokogawa 250220MTMT8JFK - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 60/600 -0 -60/600
Legend- RPM/MIN

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTMT8JFP - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-150Legend- % - Product Image

Yokogawa 250220MTMT8JFP - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $85.00
Yokogawa 250220MTNT8JEX - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-50Legend- ADC W/CH LOGO - Product Image

Yokogawa 250220MTNT8JEX - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-50
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTPK8JDS - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- DC VOLTS - Product Image

Yokogawa 250220MTPK8JDS - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220MTPK8JDW - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- ADC W/CH LOGO - Product Image

Yokogawa 250220MTPK8JDW - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTPZ8JFD - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-150Legend- DC VOLTS W/CH LOGO - Product Image

Yokogawa 250220MTPZ8JFD - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-150
Legend- DC VOLTS W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTRL8JDU - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- DC VOLTS W/WESTINGHOUSE L - Product Image

Yokogawa 250220MTRL8JDU - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- DC VOLTS W/WESTINGHOUSE L

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTRX8JDR - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-300Legend- DC VOLTS - Product Image

Yokogawa 250220MTRX8JDR - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-300
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTSJ8JEC - 2 1/2 NBL DC VOLTMETERRating- 0-10 V/DCScale- 0-600Legend- DC VOLTS W/WESTINGHOUSE - Product Image

Yokogawa 250220MTSJ8JEC - 2 1/2 NBL DC VOLTMETER

Rating- 0-10 V/DC
Scale- 0-600
Legend- DC VOLTS W/WESTINGHOUSE

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220MTTC8JFN - DC VOLT 0 LEFTRating- 0-10 V/DCScale- 0-1500Legend- DC VOLTS - Product Image

Yokogawa 250220MTTC8JFN - DC VOLT 0 LEFT

Rating- 0-10 V/DC
Scale- 0-1500
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220MTWF8JFM - 2 1/2 DC VOLTMETERRating- 0-10 V/DCScale- 0-8.0Legend- DC KILOAMPERES - Product Image

Yokogawa 250220MTWF8JFM - 2 1/2 DC VOLTMETER

Rating- 0-10 V/DC
Scale- 0-8.0
Legend- DC KILOAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $88.00
Yokogawa 250220NDND - DC VOLT 0 LEFTRating- 0-15 V/DCScale- 0-15Legend- DC VOLTS - Product Image

Yokogawa 250220NDND - DC VOLT 0 LEFT

Rating- 0-15 V/DC
Scale- 0-15
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220NDND8JFF - DC VOLT 0 LEFTRating- 0-15 V/DCScale- 0-15Legend- DC VOLTS - Product Image

Yokogawa 250220NDND8JFF - DC VOLT 0 LEFT

Rating- 0-15 V/DC
Scale- 0-15
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220NGNG - DC VOLT 0 LEFTRating- 0-20 V/DCScale- 0-20Legend- DC VOLTS - Product Image

Yokogawa 250220NGNG - DC VOLT 0 LEFT

Rating- 0-20 V/DC
Scale- 0-20
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220NGNG8JEJ - DC VOLT 0 LEFT MTG OPT 1Rating- 0-20 V/DCScale- 0-20Legend- DC VOLTS - Product Image

Yokogawa 250220NGNG8JEJ - DC VOLT 0 LEFT MTG OPT 1

Rating- 0-20 V/DC
Scale- 0-20
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220NJNJ - DC VOLT 0 LEFTRating- 0-25 V/DCScale- 0-25Legend- DC VOLTS - Product Image

Yokogawa 250220NJNJ - DC VOLT 0 LEFT

Rating- 0-25 V/DC
Scale- 0-25
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220NLNL - DC VOLT 0 LEFT - Rated & Scaled: 0-30 V/DCRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS - Product Image

Yokogawa 250220NLNL - DC VOLT 0 LEFT - Rated & Scaled: 0-30 V/DC

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220NLNL8JDX - DC AMP 0-LEFTRating- 0-30 V/DCScale- 0-30Legend- DC VOLTS TRINITY POWER LO - Product Image

Yokogawa 250220NLNL8JDX - DC AMP 0-LEFT

Rating- 0-30 V/DC
Scale- 0-30
Legend- DC VOLTS TRINITY POWER LO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220NPNP8JEP - DC VOLT 0 LEFTRating- 0-40 V/DCScale- 0-40Legend- DC VOLTS W/WAYNE BROYLES - Product Image

Yokogawa 250220NPNP8JEP - DC VOLT 0 LEFT

Rating- 0-40 V/DC
Scale- 0-40
Legend- DC VOLTS W/WAYNE BROYLES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220NTNT - DC VOLT 0 LEFTRating- 0-50 V/DCScale- 0-50Legend- DC VOLTS - Product Image

Yokogawa 250220NTNT - DC VOLT 0 LEFT

Rating- 0-50 V/DC
Scale- 0-50
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220NTNT8JED - DC VOLT 0-LEFTRating- 0-50 V/DCScale- 0-50Legend- DC VOLTS W/TRILECTRON LOG - Product Image

Yokogawa 250220NTNT8JED - DC VOLT 0-LEFT

Rating- 0-50 V/DC
Scale- 0-50
Legend- DC VOLTS W/TRILECTRON LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $73.00
Yokogawa 250220PDPD - DC VOLT 0 LEFTRating- 0-80 V/DCScale- 0-80Legend- DC VOLTS - Product Image

Yokogawa 250220PDPD - DC VOLT 0 LEFT

Rating- 0-80 V/DC
Scale- 0-80
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220PDPD7JDE - DC VOLT 0 LEFTRating- 0-80 V/DCScale- 0-80Legend- DC VOLTS - Product Image

Yokogawa 250220PDPD7JDE - DC VOLT 0 LEFT

Rating- 0-80 V/DC
Scale- 0-80
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220PDPD8JDE - DC VOLT 0 LEFTRating- 0-80 V/DCScale- 0-80Legend- DC VOLTS - Product Image

Yokogawa 250220PDPD8JDE - DC VOLT 0 LEFT

Rating- 0-80 V/DC
Scale- 0-80
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220PGPK8JDY - NBL TB PANEL METERRating- 0-90 V/DCScale- 0-100Legend- PERCENT - Product Image

Yokogawa 250220PGPK8JDY - NBL TB PANEL METER

Rating- 0-90 V/DC
Scale- 0-100
Legend- PERCENT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220PKPK - DC VOLT 0 LEFTRating- 0-100 V/DCScale- 0-100Legend- DC VOLTS - Product Image

Yokogawa 250220PKPK - DC VOLT 0 LEFT

Rating- 0-100 V/DC
Scale- 0-100
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220PKPK8JEA - 2 1/2 BL PM DC VOLTMETERRating- 0-100 V/DCScale- 0-100Legend- DC VOLTS W/WESTINGHOUSE L - Product Image

Yokogawa 250220PKPK8JEA - 2 1/2 BL PM DC VOLTMETER

Rating- 0-100 V/DC
Scale- 0-100
Legend- DC VOLTS W/WESTINGHOUSE L

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220PSPS - 2 1/2 DC VOLTMETERRating- 0-125 V/DCScale- 0-125Legend- DC VOLTS - Product Image

Yokogawa 250220PSPS - 2 1/2 DC VOLTMETER

Rating- 0-125 V/DC
Scale- 0-125
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250220PZPZ - DC VOLT 0 LEFTRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS - Product Image

Yokogawa 250220PZPZ - DC VOLT 0 LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220PZPZ8JDL - DC VOLT 0 LEFTRating- 0-150 V/DCScale- 0-150Legend- DC Volts - Product Image

Yokogawa 250220PZPZ8JDL - DC VOLT 0 LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC Volts

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220PZPZ8JFC - DC VOLT 0 LEFTRating- 0-150 V/DCScale- 0-150Legend- DC VOLTS - Product Image

Yokogawa 250220PZPZ8JFC - DC VOLT 0 LEFT

Rating- 0-150 V/DC
Scale- 0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220RLRL - DC VOLT 0 LEFTRating- 0-200 V/DCScale- 0-200Legend- DC VOLTS - Product Image

Yokogawa 250220RLRL - DC VOLT 0 LEFT

Rating- 0-200 V/DC
Scale- 0-200
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220RLRL8JDT - DC VOLT 0-LEFTRating- 0-200 V/DCScale- 0-200Legend- DC VOLTS W/CH LOGO - Product Image

Yokogawa 250220RLRL8JDT - DC VOLT 0-LEFT

Rating- 0-200 V/DC
Scale- 0-200
Legend- DC VOLTS W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220RSRS8JFJ - DC VOLT 0 LEFTRating- 0-250 V/DCScale- 0-250Legend- DC VOLTS - Product Image

Yokogawa 250220RSRS8JFJ - DC VOLT 0 LEFT

Rating- 0-250 V/DC
Scale- 0-250
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $65.00
Yokogawa 250220RXRX - DC VOLT 0 LEFTRating- 0-300 V/DCScale- 0-300Legend- DC VOLTS - Product Image

Yokogawa 250220RXRX - DC VOLT 0 LEFT

Rating- 0-300 V/DC
Scale- 0-300
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $65.00
Yokogawa 250220RXRX8JDH - DC VOLT 0 LEFTRating- 0-300 V/DCScale- 0-300Legend- DC VOLTS - Product Image

Yokogawa 250220RXRX8JDH - DC VOLT 0 LEFT

Rating- 0-300 V/DC
Scale- 0-300
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $65.00
Yokogawa 250220SCSC8JDP - DC VOLT 0-LEFT 2A95682H14Rating- 0-400 V/DCScale- 0-400Legend- DC VOLTS W/CH LOGO - Product Image

Yokogawa 250220SCSC8JDP - DC VOLT 0-LEFT 2A95682H14

Rating- 0-400 V/DC
Scale- 0-400
Legend- DC VOLTS W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $65.00
Yokogawa 250220SFSF - DC VOLT 0 LEFTRating- 0-500 V/DCScale- 0-500Legend-  - Product Image

Yokogawa 250220SFSF - DC VOLT 0 LEFT

Rating- 0-500 V/DC
Scale- 0-500
Legend-

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $65.00
Yokogawa 250220SFSF8JDJ - DC VOLT 0 LEFTRating- 0-500 V/DCScale- 0-500Legend- DC VOLTS W/CH LOGO - Product Image

Yokogawa 250220SFSF8JDJ - DC VOLT 0 LEFT

Rating- 0-500 V/DC
Scale- 0-500
Legend- DC VOLTS W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220SFSF8JFR - DC VOLT 0 LEFTRating- 0-500 V/DCScale- 0-500Legend- DC VOLTS - Product Image

Yokogawa 250220SFSF8JFR - DC VOLT 0 LEFT

Rating- 0-500 V/DC
Scale- 0-500
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220SJSJ8JDN - DC VOLT 0-LEFT 2A95682H12Rating- 0-600 V/DCScale- 0-600Legend- DC VOLT W/CH LOGO - Product Image

Yokogawa 250220SJSJ8JDN - DC VOLT 0-LEFT 2A95682H12

Rating- 0-600 V/DC
Scale- 0-600
Legend- DC VOLT W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250220SJSJ8JEW - DC VOLT 0-LEFTRating- 0-650 V/DCScale- 0-650Legend- DC VOLTS W/CH LOGO - Product Image

Yokogawa 250220SJSJ8JEW - DC VOLT 0-LEFT

Rating- 0-650 V/DC
Scale- 0-650
Legend- DC VOLTS W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $65.00
Yokogawa 250220SNSN8JDK - DC VOLT 0 LEFT - MTG OPTION 1Rating- 0-800 V/DCScale- 0-800Legend- DC VOLTS - Product Image

Yokogawa 250220SNSN8JDK - DC VOLT 0 LEFT - MTG OPTION 1

Rating- 0-800 V/DC
Scale- 0-800
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250221LSLS - DC VOLT 0-CENTERRating- 5-0-5 V/DCScale- 5-0-5Legend- DC VOLTS - Product Image

Yokogawa 250221LSLS - DC VOLT 0-CENTER

Rating- 5-0-5 V/DC
Scale- 5-0-5
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250221MTMT - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 10-0-10Legend- DC VOLTS - Product Image

Yokogawa 250221MTMT - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 10-0-10
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00

Yokogawa 250221MTMT8JAR - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- % SUB LGND - +

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250221MTMT8JAS - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 10-0-10Legend- AMPS - Product Image

Yokogawa 250221MTMT8JAS - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 10-0-10
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250221MTMT8JAT - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 100-0-100Legend- PERCENT - Product Image

Yokogawa 250221MTMT8JAT - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- PERCENT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250221MTMT8JAU - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 100-0-100Legend- % - Product Image

Yokogawa 250221MTMT8JAU - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 100-0-100
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250221MTMT8JAW - DC VOLT 0-CENTERRating- 10-0-10 V/DCScale- 150-0-150Legend- % LOAD - Product Image

Yokogawa 250221MTMT8JAW - DC VOLT 0-CENTER

Rating- 10-0-10 V/DC
Scale- 150-0-150
Legend- % LOAD

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $80.00
Yokogawa 250221NDND8JAN - 2 1/2 BL DC VOLTRating- 15-0-15 V/DCScale- 15-0-15Legend- DC VOLTS - Product Image

Yokogawa 250221NDND8JAN - 2 1/2 BL DC VOLT

Rating- 15-0-15 V/DC
Scale- 15-0-15
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250221NGNG - 2 1/2 BL DC VOLTRating- 20-0-20 V/DCScale- 20-0-20Legend- DC VOLTS - Product Image

Yokogawa 250221NGNG - 2 1/2 BL DC VOLT

Rating- 20-0-20 V/DC
Scale- 20-0-20
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250221NJNJ8JAP - DC VOLT 0-CENTER MTG OPT 1Rating- 24-0-24 V/DCScale- 24-0-24Legend- DC VOLTS - Product Image

Yokogawa 250221NJNJ8JAP - DC VOLT 0-CENTER MTG OPT 1

Rating- 24-0-24 V/DC
Scale- 24-0-24
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $65.00
Yokogawa 250221NLNL - DC VOLT 0-CENTERRating- 30-0-30 V/DCScale- 30-0-30Legend- DC VOLTS - Product Image

Yokogawa 250221NLNL - DC VOLT 0-CENTER

Rating- 30-0-30 V/DC
Scale- 30-0-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250221PDPD - DC VOLT 0-CENTERRating- 80-0-80 V/DCScale- 80-0-80Legend- DC VOLTS - Product Image

Yokogawa 250221PDPD - DC VOLT 0-CENTER

Rating- 80-0-80 V/DC
Scale- 80-0-80
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250221PZPZ - DC VOLT 0-CENTERRating- 150-0-150 V/DCScale- 150-0-150Legend- DC VOLTS - Product Image

Yokogawa 250221PZPZ - DC VOLT 0-CENTER

Rating- 150-0-150 V/DC
Scale- 150-0-150
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250221RXRX - DC VOLT 0-CENTERRating- 300-0-300 V/DCScale- 300-0-300Legend- DC VOLTS - Product Image

Yokogawa 250221RXRX - DC VOLT 0-CENTER

Rating- 300-0-300 V/DC
Scale- 300-0-300
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250221SCSC - DC VOLT 0-CENTERRating- 400-0-400 V/DCScale- 400-0-400Legend- DC VOLTS - Product Image

Yokogawa 250221SCSC - DC VOLT 0-CENTER

Rating- 400-0-400 V/DC
Scale- 400-0-400
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $60.00
Yokogawa 250224ECEC8JCC - DC mV 0-LEFTRating- 0-50 mV/DCScale- BLANKLegend- BLANK - Product Image

Yokogawa 250224ECEC8JCC - DC mV 0-LEFT

Rating- 0-50 mV/DC
Scale- BLANK
Legend- BLANK

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECHY - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-50Legend- DC MILLIAMPERES - Product Image

Yokogawa 250224ECHY - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-50
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECND8JDN - 2 1/2 INCH DC AMPERESRating- 0-50 mV/DCScale- 0-15Legend- DC AMPERES W/ALDONEX LOGO - Product Image

Yokogawa 250224ECND8JDN - 2 1/2 INCH DC AMPERES

Rating- 0-50 mV/DC
Scale- 0-15
Legend- DC AMPERES W/ALDONEX LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECNG - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-20Legend- DC AMPERES - Product Image

Yokogawa 250224ECNG - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-20
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECNL - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-30Legend- DC AMPERES - Product Image

Yokogawa 250224ECNL - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECNP8 - DC MILLIVOLTRating- 0-50 mV/DCScale- 40-0-40Legend- DC AMPERES - Product Image

Yokogawa 250224ECNP8 - DC MILLIVOLT

Rating- 0-50 mV/DC
Scale- 40-0-40
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECNT - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-50Legend- DC AMPERES - Product Image

Yokogawa 250224ECNT - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-50
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECNT8JDK - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-50Legend- DC AMPERES WAYNES BROYLES - Product Image

Yokogawa 250224ECNT8JDK - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-50
Legend- DC AMPERES WAYNES BROYLES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECPK - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-100Legend- DC AMPERES - Product Image

Yokogawa 250224ECPK - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-100
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECPK8JDP - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-100Legend- DC AMPERES W/BONITRON LOG - Product Image

Yokogawa 250224ECPK8JDP - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-100
Legend- DC AMPERES W/BONITRON LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECPZ - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-150Legend- DCA - Product Image

Yokogawa 250224ECPZ - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-150
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECPZ8JCR - DC MV 0-LEFTRating- 0-50 mV/DCScale- 0-150Legend- DC AMPERES - Product Image

Yokogawa 250224ECPZ8JCR - DC MV 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-150
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECPZ8JDS - DC MV 0-LEFTRating- 0-50 mV/DCScale- 0-150Legend- DC AMPERES - Product Image

Yokogawa 250224ECPZ8JDS - DC MV 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-150
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECRL - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-200Legend- DCA - Product Image

Yokogawa 250224ECRL - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-200
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECRS - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-250Legend- DC AMPERES - Product Image

Yokogawa 250224ECRS - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-250
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $74.00
Yokogawa 250224ECRX - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-300Legend- DC AMPERES - Product Image

Yokogawa 250224ECRX - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-300
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECSC - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-400Legend- DCA - Product Image

Yokogawa 250224ECSC - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-400
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECSF - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-500Legend- DC AMPERES - Product Image

Yokogawa 250224ECSF - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-500
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECSJ - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-600Legend- DCA - Product Image

Yokogawa 250224ECSJ - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-600
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECSN - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-800Legend- DCA - Product Image

Yokogawa 250224ECSN - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-800
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECSS - DC MV 0 LEFTRating- 0-50 mV/DCScale- 0-1000Legend- DC AMPERES - Product Image

Yokogawa 250224ECSS - DC MV 0 LEFT

Rating- 0-50 mV/DC
Scale- 0-1000
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECVB8JCG - DC MILLIVOLT 0-LEFT MTG OPT 1Rating- 0-50 mV/DCScale- 0-1.2Legend- DC KILOAMPERES - Product Image

Yokogawa 250224ECVB8JCG - DC MILLIVOLT 0-LEFT MTG OPT 1

Rating- 0-50 mV/DC
Scale- 0-1.2
Legend- DC KILOAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224ECVE8JDC - DC MV 0-LEFTRating- 0-50 mV/DCScale- 0-2.0Legend- KA DC W/CH LOGO - Product Image

Yokogawa 250224ECVE8JDC - DC MV 0-LEFT

Rating- 0-50 mV/DC
Scale- 0-2.0
Legend- KA DC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.00
Yokogawa 250224GBLS - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-5Legend- DC AMPERES - Product Image

Yokogawa 250224GBLS - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-5
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBLS8JDL - DC MV 0 LEFT MTG OP #1Rating- 0-100 mV/DCScale- 0-5Legend- ADC W/CH LOGO - Product Image

Yokogawa 250224GBLS8JDL - DC MV 0 LEFT MTG OP #1

Rating- 0-100 mV/DC
Scale- 0-5
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBMT8JCN - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-10Legend- ADC W/CH LOGO - Product Image

Yokogawa 250224GBMT8JCN - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-10
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBND8JCK - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-15Legend- ADC W/CH LOGO - Product Image

Yokogawa 250224GBND8JCK - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-15
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBNG - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-20Legend- DCA - Product Image

Yokogawa 250224GBNG - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-20
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBNG8JCJ - DC MILLIVOLTRating- 0-100 mV/DCScale- 0-20Legend- ADC - Product Image

Yokogawa 250224GBNG8JCJ - DC MILLIVOLT

Rating- 0-100 mV/DC
Scale- 0-20
Legend- ADC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBNJ8JCS - DC MILLIVOLTRating- 0-100 mV/DCScale- 0-25Legend- ADC W/WESTINGHOUSE LOGO - Product Image

Yokogawa 250224GBNJ8JCS - DC MILLIVOLT

Rating- 0-100 mV/DC
Scale- 0-25
Legend- ADC W/WESTINGHOUSE LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBNL8JCT - DC MILLIVOLTRating- 0-100 mV/DCScale- 0-30Legend- DC AMPERES - Product Image

Yokogawa 250224GBNL8JCT - DC MILLIVOLT

Rating- 0-100 mV/DC
Scale- 0-30
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBNP8JCU - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-40Legend- ADC W/WESTINGHOUSE LOGO - Product Image

Yokogawa 250224GBNP8JCU - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-40
Legend- ADC W/WESTINGHOUSE LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBNT - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-50Legend- DCA - Product Image

Yokogawa 250224GBNT - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-50
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBNT8JCE - DC MILLIVOLT 0-LEFTRating- 0-100 mV/DCScale- 0-50Legend- A DC WITH CH LOGO - Product Image

Yokogawa 250224GBNT8JCE - DC MILLIVOLT 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-50
Legend- A DC WITH CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBPB8JCD - DC MV MTG OPT 1Rating- 0-100 mV/DCScale- 0-75Legend- ADC W/CH LOGO - Product Image

Yokogawa 250224GBPB8JCD - DC MV MTG OPT 1

Rating- 0-100 mV/DC
Scale- 0-75
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBPK - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-100Legend- DCA - Product Image

Yokogawa 250224GBPK - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-100
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBPK8JBZ - DC MVRating- 0-100 mV/DCScale- 0-100Legend- ADC W/W LOGO NO SILVER P - Product Image

Yokogawa 250224GBPK8JBZ - DC MV

Rating- 0-100 mV/DC
Scale- 0-100
Legend- ADC W/W LOGO NO SILVER P

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBPZ - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-150Legend- DCA - Product Image

Yokogawa 250224GBPZ - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-150
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBPZ8JDA - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-150Legend- A DC W/CH LOGO - Product Image

Yokogawa 250224GBPZ8JDA - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-150
Legend- A DC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBRL8JDM - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-200Legend- ADC W/CH LOGO - Product Image

Yokogawa 250224GBRL8JDM - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-200
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBRS8JCP - DC MILLIVOLT 0-LEFTRating- 0-100 mV/DCScale- 0-250Legend- DC AMPERES - Product Image

Yokogawa 250224GBRS8JCP - DC MILLIVOLT 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-250
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBRX8JCF - DC mV 0-LEFTRating- 0-100 mV/DCScale- 0-300Legend- ADC W/CH LOGO - Product Image

Yokogawa 250224GBRX8JCF - DC mV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-300
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBSF8JDB - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-500Legend- ADC W/CH LOGO - Product Image

Yokogawa 250224GBSF8JDB - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-500
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $74.00
Yokogawa 250224GBSN8JBU - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-800Legend- ADC W/CH LOGO - Product Image

Yokogawa 250224GBSN8JBU - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-800
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBSV8JCW - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-1200Legend- ADC - Product Image

Yokogawa 250224GBSV8JCW - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-1200
Legend- ADC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBSV8JCZ - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-1200Legend- ADC W/CH LOGO - Product Image

Yokogawa 250224GBSV8JCZ - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-1200
Legend- ADC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBUE8JBW - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-4000Legend- A DC W/WESTINGHOUSE LOGO - Product Image

Yokogawa 250224GBUE8JBW - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-4000
Legend- A DC W/WESTINGHOUSE LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBUE8JCB - DC AMMETERRating- 0-100 mV/DCScale- 0-4000Legend- A DC W/WESTINGHOUSE LOGO - Product Image

Yokogawa 250224GBUE8JCB - DC AMMETER

Rating- 0-100 mV/DC
Scale- 0-4000
Legend- A DC W/WESTINGHOUSE LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBUE8JCH - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-4000Legend- ADC WESTINGHOUSE LOGO - Product Image

Yokogawa 250224GBUE8JCH - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-4000
Legend- ADC WESTINGHOUSE LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBUP8JDR - DC MILLIVOLT - 0 LEFT - W/CH LOGORating- 0-100 mV/DCScale- 0-6000Legend- DC AMPERES - Product Image

Yokogawa 250224GBUP8JDR - DC MILLIVOLT - 0 LEFT - W/CH LOGO

Rating- 0-100 mV/DC
Scale- 0-6000
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBUS8JDG - DC AMMETERRating- 0-100 mV/DCScale- 0-7000Legend- DC AMPERES - Product Image

Yokogawa 250224GBUS8JDG - DC AMMETER

Rating- 0-100 mV/DC
Scale- 0-7000
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBVA8JDE - DC MV 0-LEFT MTG OPT 1Rating- 0-100 mV/DCScale- 0-1.0Legend- KA DC W/CH LOGO - Product Image

Yokogawa 250224GBVA8JDE - DC MV 0-LEFT MTG OPT 1

Rating- 0-100 mV/DC
Scale- 0-1.0
Legend- KA DC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBVB8JAG - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-1200Legend- DC AMPERES - Product Image

Yokogawa 250224GBVB8JAG - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-1200
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBVC8JCL - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-1.5Legend- KA DC W/CH LOGO - Product Image

Yokogawa 250224GBVC8JCL - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-1.5
Legend- KA DC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBVE8JDD - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-2.0Legend- KADC W/WESTINGHOUSE LOGO - Product Image

Yokogawa 250224GBVE8JDD - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-2.0
Legend- KADC W/WESTINGHOUSE LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBVE8JDJ - DC LEFT 0-2000 SCALERating- 0-100 mV/DCScale- 0-2000Legend- ADC W/WESTINGHOUSE LOGO - Product Image

Yokogawa 250224GBVE8JDJ - DC LEFT 0-2000 SCALE

Rating- 0-100 mV/DC
Scale- 0-2000
Legend- ADC W/WESTINGHOUSE LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $66.00
Yokogawa 250224GBVG8JDH - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-2.5Legend- DC KILOAMPERES W/TRILECTR - Product Image

Yokogawa 250224GBVG8JDH - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-2.5
Legend- DC KILOAMPERES W/TRILECTR

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBVJ8JCM - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-3.0Legend- DC KILOAMPERES - Product Image

Yokogawa 250224GBVJ8JCM - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-3.0
Legend- DC KILOAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBVT8JBY - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-5.0Legend- KA DC - Product Image

Yokogawa 250224GBVT8JBY - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-5.0
Legend- KA DC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBVX8JDF - DC MV 0-LEFTRating- 0-100 mV/DCScale- 0-6Legend- KA DC - Product Image

Yokogawa 250224GBVX8JDF - DC MV 0-LEFT

Rating- 0-100 mV/DC
Scale- 0-6
Legend- KA DC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $81.50
Yokogawa 250224GBWF8JBX - DC MV 0 LEFTRating- 0-100 mV/DCScale- 0-8.0Legend- KA DC W/CH LOGO - Product Image

Yokogawa 250224GBWF8JBX - DC MV 0 LEFT

Rating- 0-100 mV/DC
Scale- 0-8.0
Legend- KA DC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250224GBWM8JCY - DC MV 0-LEFT MTG OPT 1Rating- 0-100 mV/DCScale- 0-10.0Legend- KA DC W/CH LOGO - Product Image

Yokogawa 250224GBWM8JCY - DC MV 0-LEFT MTG OPT 1

Rating- 0-100 mV/DC
Scale- 0-10.0
Legend- KA DC W/CH LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250225ECNJ - DC MILLIVOLT 0-CRating- 50-0-50 mV/DCScale- 25-0-25Legend- DC AMPERES - Product Image

Yokogawa 250225ECNJ - DC MILLIVOLT 0-C

Rating- 50-0-50 mV/DC
Scale- 25-0-25
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250225ECNL8JAZ - DC MV 0-CENTERRating- 50-0-50 mV/DCScale- 30-0-30Legend- DC AMPERES SHUNT EXTERNAL - Product Image

Yokogawa 250225ECNL8JAZ - DC MV 0-CENTER

Rating- 50-0-50 mV/DC
Scale- 30-0-30
Legend- DC AMPERES SHUNT EXTERNAL

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250225ECNT - DC MILLIVOLT 0-CRating- 50-0-50 mV/DCScale- 50-0-50Legend- DCA - Product Image

Yokogawa 250225ECNT - DC MILLIVOLT 0-C

Rating- 50-0-50 mV/DC
Scale- 50-0-50
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250225ECNT8JBA - DC MILLIVOLT 0-CRating- 50-0-50 mV/DCScale- 50-0-50Legend- DC AMPERES SHUNT EXTERNAL - Product Image

Yokogawa 250225ECNT8JBA - DC MILLIVOLT 0-C

Rating- 50-0-50 mV/DC
Scale- 50-0-50
Legend- DC AMPERES SHUNT EXTERNAL

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250225ECPZ - DC MILLIVOLT 0-CRating- 50-0-50 mV/DCScale- 150-0-150Legend- DCA - Product Image

Yokogawa 250225ECPZ - DC MILLIVOLT 0-C

Rating- 50-0-50 mV/DC
Scale- 150-0-150
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250225GBSC - DC MILLIVOLT 0-CRating- 100-0-100 mV/DCScale- 400-0-400Legend- DCA - Product Image

Yokogawa 250225GBSC - DC MILLIVOLT 0-C

Rating- 100-0-100 mV/DC
Scale- 400-0-400
Legend- DCA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250225GBTC8JBB - DC MILLIVOLT 0-CRating- 100-0-100 mV/DCScale- 1500-0-1500Legend-  - Product Image

Yokogawa 250225GBTC8JBB - DC MILLIVOLT 0-C

Rating- 100-0-100 mV/DC
Scale- 1500-0-1500
Legend-

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $82.00
Yokogawa 250320LALA7JEM - DC VOLT 0-LEFTRating- 0-1 V/DCScale- 0-150Legend- PERCENT LOAD - Product Image

Yokogawa 250320LALA7JEM - DC VOLT 0-LEFT

Rating- 0-1 V/DC
Scale- 0-150
Legend- PERCENT LOAD

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LALA8JEM - DC VOLTRating- 0-1 V/DCScale- 0-150Legend- % LOADRed Band- 100-150 - Product Image

Yokogawa 250320LALA8JEM - DC VOLT

Rating- 0-1 V/DC
Scale- 0-150
Legend- % LOAD
Red Band- 100-150

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00

Yokogawa 250320LALA8JJU - 3 1/2 BL DC VOLTMETER

Rating- 0-1 V/DC
Scale- -40 - +10/-40 - -12
Legend- DEG=F/DEG=C

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LALA8JUP - DC VOLT 0-LEFTRating- 0-1 V/DCScale- 0-.050Legend-  - Product Image

Yokogawa 250320LALA8JUP - DC VOLT 0-LEFT

Rating- 0-1 V/DC
Scale- 0-.050
Legend-

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LALA8KAJ - DC VOLT 0-LEFT (OIL DAMPED)Rating- 0-1 V/DCScale- 0-1Legend- AC VOLTS - Product Image

Yokogawa 250320LALA8KAJ - DC VOLT 0-LEFT (OIL DAMPED)

Rating- 0-1 V/DC
Scale- 0-1
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $118.00
Yokogawa 250320LCLC7AAD - DC VOLT 0-LEFTRating- 0-1.5 V/DCScale- 0-150Legend- PERCENT LOAD - Product Image

Yokogawa 250320LCLC7AAD - DC VOLT 0-LEFT

Rating- 0-1.5 V/DC
Scale- 0-150
Legend- PERCENT LOAD

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LJLJ - DC VOLT 0-LEFTRating- 0-3 V/DCScale- 0-3Legend- VDC - Product Image

Yokogawa 250320LJLJ - DC VOLT 0-LEFT

Rating- 0-3 V/DC
Scale- 0-3
Legend- VDC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320LJLJ8JPS - DC VOLT 0-LEFTRating- 0-3 V/DCScale- 0-200Legend- % - Product Image

Yokogawa 250320LJLJ8JPS - DC VOLT 0-LEFT

Rating- 0-3 V/DC
Scale- 0-200
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LJLJ8JXY - DC VOLT 0-LEFT - 3AUA569001BRating- 0-2.88 V/DCScale- 0-500Legend- AMPS DC - Product Image

Yokogawa 250320LJLJ8JXY - DC VOLT 0-LEFT - 3AUA569001B

Rating- 0-2.88 V/DC
Scale- 0-500
Legend- AMPS DC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LJLJ8JXZ - DC VOLT 0-LEFT - 3AUA569001B4Rating- 0-3.6 V/DCScale- 0-300Legend- AMPS DC - Product Image

Yokogawa 250320LJLJ8JXZ - DC VOLT 0-LEFT - 3AUA569001B4

Rating- 0-3.6 V/DC
Scale- 0-300
Legend- AMPS DC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LJLJ8KAG - DC VOLT 0-LEFTRating- 0-3 V/DCScale- 0-3Legend- (NONE) - Product Image

Yokogawa 250320LJLJ8KAG - DC VOLT 0-LEFT

Rating- 0-3 V/DC
Scale- 0-3
Legend- (NONE)

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-5Legend- VDC - Product Image

Yokogawa 250320LSLS - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-5
Legend- VDC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320LSLS8JRX - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-325Legend- AMP - Product Image

Yokogawa 250320LSLS8JRX - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-325
Legend- AMP

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS8JRY - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-825Legend- AMP - Product Image

Yokogawa 250320LSLS8JRY - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-825
Legend- AMP

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS8JRZ - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-100Legend- % SPEED - Product Image

Yokogawa 250320LSLS8JRZ - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-100
Legend- % SPEED

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS8JTP - DC VOLT 0-CENTERRating- 0-5 V/DCScale- 0-1025Legend- AMPS - Product Image

Yokogawa 250320LSLS8JTP - DC VOLT 0-CENTER

Rating- 0-5 V/DC
Scale- 0-1025
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS8JTR - DC VOLT 0-CENTERRating- 0-5 V/DCScale- 0-500Legend- V AC - Product Image

Yokogawa 250320LSLS8JTR - DC VOLT 0-CENTER

Rating- 0-5 V/DC
Scale- 0-500
Legend- V AC

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS8JUX - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-200Legend- % - Product Image

Yokogawa 250320LSLS8JUX - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-200
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320LSLS8JYA - DC VOLT 0-LEFT - 10,000 OHMS/VOLRating- 0-5 V/DCScale- 0-1000Legend- DC MILLAMPERES - Product Image

Yokogawa 250320LSLS8JYA - DC VOLT 0-LEFT - 10,000 OHMS/VOL

Rating- 0-5 V/DC
Scale- 0-1000
Legend- DC MILLAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS8JYR - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-2000Legend- DC MILLIAMPERES - Product Image

Yokogawa 250320LSLS8JYR - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-2000
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320LSLS8JZC - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-90Legend- HERTZ - Product Image

Yokogawa 250320LSLS8JZC - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-90
Legend- HERTZ

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320LSLS8JZX - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-3000Legend- DC MILIAMPS - Product Image

Yokogawa 250320LSLS8JZX - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-3000
Legend- DC MILIAMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320LSLS8KAL - DC VOLT 0-LEFT - 10,000 OHMS/VOLRating- 0-5 V/DCScale- 0-60Legend- DC KILOVOLTS - Product Image

Yokogawa 250320LSLS8KAL - DC VOLT 0-LEFT - 10,000 OHMS/VOL

Rating- 0-5 V/DC
Scale- 0-60
Legend- DC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS8KAM - DC VOLT 0-LEFT - 10,000 OHMS/VOLRating- 0-5 V/DCScale- 0-500Legend- DC MILLIAMPERES - Product Image

Yokogawa 250320LSLS8KAM - DC VOLT 0-LEFT - 10,000 OHMS/VOL

Rating- 0-5 V/DC
Scale- 0-500
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS8KAR - DC VOLT 0-LEFT - 10,000 OHMS/VOLRating- 0-5 V/DCScale- 0-3000Legend- DC MILLIAMPERES - Product Image

Yokogawa 250320LSLS8KAR - DC VOLT 0-LEFT - 10,000 OHMS/VOL

Rating- 0-5 V/DC
Scale- 0-3000
Legend- DC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSLS8KAZ - DC VOLT 0-LEFT (BLACK BEZEL)Rating- 0-4.55 V/DCScale- 0-5000Legend- DC AMPERES - Product Image

Yokogawa 250320LSLS8KAZ - DC VOLT 0-LEFT (BLACK BEZEL)

Rating- 0-4.55 V/DC
Scale- 0-5000
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSPR8JZF - DC VOLTMETER (BHA LOGO)Rating- 0-5 V/DCScale- 0-120Legend- DC KILOVOLTS - Product Image

Yokogawa 250320LSPR8JZF - DC VOLTMETER (BHA LOGO)

Rating- 0-5 V/DC
Scale- 0-120
Legend- DC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSSC8KAE - DC VOLT 0-LEFTRating- 0-4.8 V/DCScale- 0-400Legend- DC AMPERES - Product Image

Yokogawa 250320LSSC8KAE - DC VOLT 0-LEFT

Rating- 0-4.8 V/DC
Scale- 0-400
Legend- DC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSYF7JYS - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-80Legend- DC KILOVOLTS - Product Image

Yokogawa 250320LSYF7JYS - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-80
Legend- DC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSYL8JZR - DC VOLT 0-LEFTRating- 0-5 V/DCScale- 0-100Legend- DC KILOVOLTS - Product Image

Yokogawa 250320LSYL8JZR - DC VOLT 0-LEFT

Rating- 0-5 V/DC
Scale- 0-100
Legend- DC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320LSYL8KAS - DC VOLT 0-LEFT - 10,000 OHMS/VOLRating- 0-5 V/DCScale- 0-100Legend- DC KILOVOLTS - Product Image

Yokogawa 250320LSYL8KAS - DC VOLT 0-LEFT - 10,000 OHMS/VOL

Rating- 0-5 V/DC
Scale- 0-100
Legend- DC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MJMJ8KBF - DC VOLT 0-LEFTRating- 0-8 V/DCScale- 0-3000Legend- RPM - Product Image

Yokogawa 250320MJMJ8KBF - DC VOLT 0-LEFT

Rating- 0-8 V/DC
Scale- 0-3000
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTLE8JTK - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-2Legend- AMPERES - Product Image

Yokogawa 250320MTLE8JTK - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-2
Legend- AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MTLJ8JSA - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-3Legend- AMPERES - Product Image

Yokogawa 250320MTLJ8JSA - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-3
Legend- AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MTLS8JSB - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-5Legend- AMPERES - Product Image

Yokogawa 250320MTLS8JSB - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-5
Legend- AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MTMT - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- DC VOLTS - Product Image

Yokogawa 250320MTMT - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- DC VOLTS

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $61.00
Yokogawa 250320MTMT7JFE - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-200Legend- KILOWATTS - Product Image

Yokogawa 250320MTMT7JFE - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-200
Legend- KILOWATTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MTMT8JJM - 3 1/2 INCH VOLTMETER DCRating- 0-10 V/DCScale- 0-100Legend- PERCENT - Product Image

Yokogawa 250320MTMT8JJM - 3 1/2 INCH VOLTMETER DC

Rating- 0-10 V/DC
Scale- 0-100
Legend- PERCENT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JLA - DC VOLTRating- 0-10 V/DCScale- 0-200Legend- PERCENT - Product Image

Yokogawa 250320MTMT8JLA - DC VOLT

Rating- 0-10 V/DC
Scale- 0-200
Legend- PERCENT

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $61.00
Yokogawa 250320MTMT8JLM - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- AMPERES - Product Image

Yokogawa 250320MTMT8JLM - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MTMT8JMB - DC VOLT 0-LEFTRating- 0-2/11 V/DCScale- 0-100Legend- PERCENT SPEED - Product Image

Yokogawa 250320MTMT8JMB - DC VOLT 0-LEFT

Rating- 0-2/11 V/DC
Scale- 0-100
Legend- PERCENT SPEED

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JPD - NBL,T.B.,TACH INDICATORRating- 0-10 V/DCScale- 0-1200Legend- RPM - Product Image

Yokogawa 250320MTMT8JPD - NBL,T.B.,TACH INDICATOR

Rating- 0-10 V/DC
Scale- 0-1200
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MTMT8JPH - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1500Legend- AMP - Product Image

Yokogawa 250320MTMT8JPH - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1500
Legend- AMP

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MTMT8JPJ - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-12Legend- KILOAMPS - Product Image

Yokogawa 250320MTMT8JPJ - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-12
Legend- KILOAMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MTMT8JPK - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-625Legend- RPM - Product Image

Yokogawa 250320MTMT8JPK - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-625
Legend- RPM

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.00
Yokogawa 250320MTMT8JPM - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10000Legend- PSI - Product Image

Yokogawa 250320MTMT8JPM - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10000
Legend- PSI

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JPN - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- RPM - Product Image

Yokogawa 250320MTMT8JPN - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- RPM

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $86.50
Yokogawa 250320MTMT8JPP - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- AMPS - Product Image

Yokogawa 250320MTMT8JPP - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- AMPS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JPW - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1000Legend- TONS - Product Image

Yokogawa 250320MTMT8JPW - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1000
Legend- TONS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JPX - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-1200Legend- NONE - Product Image

Yokogawa 250320MTMT8JPX - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-1200
Legend- NONE

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JPY - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-2000Legend- NONE - Product Image

Yokogawa 250320MTMT8JPY - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-2000
Legend- NONE

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JSC - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-10Legend- AMPERES - Product Image

Yokogawa 250320MTMT8JSC - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-10
Legend- AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50
Yokogawa 250320MTMT8JTL - DC VOLT 0-LEFTRating- 0-10 V/DCScale- 0-100Legend- % - Product Image

Yokogawa 250320MTMT8JTL - DC VOLT 0-LEFT

Rating- 0-10 V/DC
Scale- 0-100
Legend- %

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $86.50