1. WEIonline Shop >
  2. Product Categories >
  3. Analog Panel Meters >

Buy AC Voltage Panel Meter | W.E.I. Inc

Yokogawa 250344SJSJ7JSA - AC VOLT I/VRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250344SJSJ7JSA - AC VOLT I/V

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $101.50
Yokogawa 250344SJSJ7JSC - AC VOLT I/VRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250344SJSJ7JSC - AC VOLT I/V

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $101.50
Yokogawa 250344SJSJ7JSH - AC VOLT I/VRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS W/AC GENTROL LOG - Product Image

Yokogawa 250344SJSJ7JSH - AC VOLT I/V

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS W/AC GENTROL LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $101.50
Yokogawa 250344SJSJ7JSR - AC VOLT I/VRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250344SJSJ7JSR - AC VOLT I/V

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250344SJSJ7JSW - VACRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250344SJSJ7JSW - VAC

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250344SJSJ7JTB - AC VOLT I/VRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS W/AC GENTROL LOG - Product Image

Yokogawa 250344SJSJ7JTB - AC VOLT I/V

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS W/AC GENTROL LOG

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250344SJSJ7JTH - AC VOLT I/V MTG OPT 1Rating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250344SJSJ7JTH - AC VOLT I/V MTG OPT 1

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $69.00
Yokogawa 250344SJSJ7JTP - AC VOLT I/V - 60HzRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250344SJSJ7JTP - AC VOLT I/V - 60Hz

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $101.50
Yokogawa 250344SJSJ7JUC - AC VOLT I/VRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250344SJSJ7JUC - AC VOLT I/V

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250344SJSJ7JUE - AC VOLT I/V BLK BEZEL 4 STUDSRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250344SJSJ7JUE - AC VOLT I/V BLK BEZEL 4 STUDS

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $89.00
Yokogawa 250344SJSJ7JUX - AC VOLT I/V - 60HzRating- 0-600 V/ACScale- 0-1Legend- KV - Product Image

Yokogawa 250344SJSJ7JUX - AC VOLT I/V - 60Hz

Rating- 0-600 V/AC
Scale- 0-1
Legend- KV

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $75.00
Yokogawa 250344SJSJ7JWA - AC VOLT I/VRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250344SJSJ7JWA - AC VOLT I/V

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $93.71
Yokogawa 250344SMSM - AC VOLT I/VRating- 0-750 V/ACScale- 0-750Legend- AC VOLTS - Product Image

Yokogawa 250344SMSM - AC VOLT I/V

Rating- 0-750 V/AC
Scale- 0-750
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $69.00
Yokogawa 250344SMSM7JUP - AC VOLT I/VRating- 0-750 V/ACScale- 0-750Legend- AC VOLTS - Product Image

Yokogawa 250344SMSM7JUP - AC VOLT I/V

Rating- 0-750 V/AC
Scale- 0-750
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $69.00
Yokogawa 250345PZPZ - AC VOLT 400HZRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Yokogawa 250345PZPZ - AC VOLT 400HZ

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $85.00
Yokogawa 250345PZPZ7JAH - 3 1/2 NBL AC VOLTMETER-400HzRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Yokogawa 250345PZPZ7JAH - 3 1/2 NBL AC VOLTMETER-400Hz

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $85.00
Yokogawa 250345PZPZ7JAL - AC VOLT I/V 400HZRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS TRILECTRON LOGO - Product Image

Yokogawa 250345PZPZ7JAL - AC VOLT I/V 400HZ

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS TRILECTRON LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $85.00
Yokogawa 250345PZPZ7JAP - AC VOLT 400HZRating- 0-150 V/ACScale- 0-250/500Legend- VOLTMETER - Product Image

Yokogawa 250345PZPZ7JAP - AC VOLT 400HZ

Rating- 0-150 V/AC
Scale- 0-250/500
Legend- VOLTMETER

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $85.00
Yokogawa 250345PZPZ7JAS - AC VOLT 400HZRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS W/GREENLEE/BEHA - Product Image

Yokogawa 250345PZPZ7JAS - AC VOLT 400HZ

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS W/GREENLEE/BEHA

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $85.00
Yokogawa 250345PZPZ7JAT - AC VOLT 400HZRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Yokogawa 250345PZPZ7JAT - AC VOLT 400HZ

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $85.00
Yokogawa 250345PZSJ - AC VOLT 400HZRating- 0-150 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250345PZSJ - AC VOLT 400HZ

Rating- 0-150 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250345PZSJ7JNS - AC VOLTRating- 0-150 V/ACScale- 0-600Legend- V - Product Image

Yokogawa 250345PZSJ7JNS - AC VOLT

Rating- 0-150 V/AC
Scale- 0-600
Legend- V

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $76.00
Yokogawa 250345PZSM - AC VOLT 400HZRating- 0-150 V/ACScale- 0-750Legend- AC VOLTS - Product Image

Yokogawa 250345PZSM - AC VOLT 400HZ

Rating- 0-150 V/AC
Scale- 0-750
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250345PZVV7 - 3 1/2 INCH BLPM 400HZRating- 0-150 V/ACScale- 0-5.25Legend- AC KILOVOLTS - Product Image

Yokogawa 250345PZVV7 - 3 1/2 INCH BLPM 400HZ

Rating- 0-150 V/AC
Scale- 0-5.25
Legend- AC KILOVOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $62.00
Yokogawa 250345RSRS7 - AC VOLT 400HZRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Yokogawa 250345RSRS7 - AC VOLT 400HZ

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $69.00
Yokogawa 250345RSRS7JAK - AC VOLT 400 HZRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Yokogawa 250345RSRS7JAK - AC VOLT 400 HZ

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $69.00
Yokogawa 250345RSRS7JAR - AC VOLT 400HZRating- 0-250 V/ACScale- 0-250/500Legend- AC VOLTS - Product Image

Yokogawa 250345RSRS7JAR - AC VOLT 400HZ

Rating- 0-250 V/AC
Scale- 0-250/500
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $82.00
Yokogawa 250345RXRX - AC VOLT 400HZRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Yokogawa 250345RXRX - AC VOLT 400HZ

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $82.00
Yokogawa 250345RXRX7JAG - 3 1/2 INCH BLPMRating- 0-300 V/ACScale- 0-300Legend- V AC WITH STEW-STEV LOGO - Product Image

Yokogawa 250345RXRX7JAG - 3 1/2 INCH BLPM

Rating- 0-300 V/AC
Scale- 0-300
Legend- V AC WITH STEW-STEV LOGO

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $82.00
Yokogawa 250345RXRX7JAM - AC VOLT I/V 400HZRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Yokogawa 250345RXRX7JAM - AC VOLT I/V 400HZ

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $88.00
Yokogawa 250345RXRX7JAN - AC VOLT 400 HETRZRating- 0-300 V/ACScale- 0-300Legend- AC VOTLS - Product Image

Yokogawa 250345RXRX7JAN - AC VOLT 400 HETRZ

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOTLS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $82.00
Yokogawa 250345RXRX7JAU - AC VOLTRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Yokogawa 250345RXRX7JAU - AC VOLT

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $69.00
Yokogawa 250345SJSJ7 - AC VOLT 400 HERTZRating- 0-600 V/ACScale- 0-600Legend- AC VOLTS - Product Image

Yokogawa 250345SJSJ7 - AC VOLT 400 HERTZ

Rating- 0-600 V/AC
Scale- 0-600
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $82.00
Yokogawa 250410FAFA - AC AMP RECTIFIEDRating- 0-1 mA/DCScale- Legend-  - Product Image

Yokogawa 250410FAFA - AC AMP RECTIFIED

Rating- 0-1 mA/DC
Scale-
Legend-

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.00
Yokogawa 250410FXFX - AC AMP RECTIFIEDRating- 0-5 mA/ACScale- 0-5Legend- AC MILLIAMPERES - Product Image

Yokogawa 250410FXFX - AC AMP RECTIFIED

Rating- 0-5 mA/AC
Scale- 0-5
Legend- AC MILLIAMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.00
Yokogawa 250410HFHF - AC AMP RECTIFIEDRating- 0-20 mA/DCScale- Legend-  - Product Image

Yokogawa 250410HFHF - AC AMP RECTIFIED

Rating- 0-20 mA/DC
Scale-
Legend-

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.00
Yokogawa 260330RLRL9JAK - TYPE 260 - AC RECTIFIEDRating- 0-200 V/ACScale- 0-115Legend- % OUTPUT VOLTAGE - Product Image

Yokogawa 260330RLRL9JAK - TYPE 260 - AC RECTIFIED

Rating- 0-200 V/AC
Scale- 0-115
Legend- % OUTPUT VOLTAGE

Manufacture: Yokogawa
Product Description: The stylist series panel meters are available in window mount and surface mount styles and all meters meet ANSI specification C39.1. These meters are available in a variety of sizes, from 1.5 to 4.5in, and feature a 90 degree arc in the AC iron vane version and a 95 degree deflection in the taut band and pivot and jewel models.

SPECIFICATIONS
Accuracy: All DC and AC iron vane, +-2% of fullscale, AC rectifier type; +-3% of fullscale (60 Hz sinewave). Expanded scale voltmeters +-5% of fullscale. Special order DC with mirror back scale (DC only) 3-1/2 - 4-1/2in Available at +-1%.
ANSI Specification: All meters meet ANSI Specifications C-39.1 (See page 14 of Panel Meter Catalog PDF for exceptions.)
Overload: Voltmeters (AC + DC) - 50% momentary, 20% sustained. Ammeters (AC +DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 seconds with 1 minute interval between successive applications; sustained: 20% for six hours.

Scale Data:
AC IRON VANE
N/A for 1-1/2in model
2.15in for 2-1/2in model
2.70in for 3-1/2in model
3.80in for 4-1/2in model
TAUT BAND/PIVOT & JEWEL
1.66in for 1-1/2in model
2.29in for 2-1/2in model
2.85in for 3-1/2in model
4.01in for 4-1/2in model
ARC:
AC IRON VANE - 90%
TAUT BAND/PIVOT & JEWEL - 95%
Insulation Level: 2600V/1 min. (2-1/2in - 4-1/2in); 1500V/1 min. (1 1/2in)

Response Time:
3 seconds (Max.) - Microammeters
2 seconds (Max.) - All other DC ratings
2.5 seconds (Max.) - All AC ratings
Maximum 40% overshoot
Burden Data: AC Ammeter 5 amps at 60 Hz, 0.5VA, Max. .5 Power factor lagging, AC voltmeter - unity power factor.

Note:
Severe-duty meters are available to meet CUL or UL 1437 requirements in 2-1/2in - 4-1/2in sizes.

Three Mounting Types Available in Stylist Series: Rear Panel Window Mount, Front of Panel Surface Mount, Rear Panel Surface Mount Available with Optional Bezel

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters.Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanism
 
 Price: $84.62
Yokogawa 260230MTNDW0001 - TYPE 260 AC RECTIFIED VOLTMETERRating- 0-10 V/ACScale- 0-15Legend- AC AMPERES - Product Image

Yokogawa 260230MTNDW0001 - TYPE 260 AC RECTIFIED VOLTMETER

Rating- 0-10 V/AC
Scale- 0-15
Legend- AC AMPERES

Manufacture: Yokogawa
Product Description: The stylist series panel meters are available in window mount and surface mount styles and all meters meet ANSI specification C39.1. These meters are available in a variety of sizes, from 1.5 to 4.5in, and feature a 90 degree arc in the AC iron vane version and a 95 degree deflection in the taut band and pivot and jewel models.

SPECIFICATIONS
Accuracy: All DC and AC iron vane, +-2% of fullscale, AC rectifier type; +-3% of fullscale (60 Hz sinewave). Expanded scale voltmeters +-5% of fullscale. Special order DC with mirror back scale (DC only) 3-1/2 - 4-1/2in Available at +-1%.
ANSI Specification: All meters meet ANSI Specifications C-39.1 (See page 14 of Panel Meter Catalog PDF for exceptions.)
Overload: Voltmeters (AC + DC) - 50% momentary, 20% sustained. Ammeters (AC +DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 seconds with 1 minute interval between successive applications; sustained: 20% for six hours.

Scale Data:
AC IRON VANE
N/A for 1-1/2in model
2.15in for 2-1/2in model
2.70in for 3-1/2in model
3.80in for 4-1/2in model
TAUT BAND/PIVOT & JEWEL
1.66in for 1-1/2in model
2.29in for 2-1/2in model
2.85in for 3-1/2in model
4.01in for 4-1/2in model
ARC:
AC IRON VANE - 90%
TAUT BAND/PIVOT & JEWEL - 95%
Insulation Level: 2600V/1 min. (2-1/2in - 4-1/2in); 1500V/1 min. (1 1/2in)

Response Time:
3 seconds (Max.) - Microammeters
2 seconds (Max.) - All other DC ratings
2.5 seconds (Max.) - All AC ratings
Maximum 40% overshoot
Burden Data: AC Ammeter 5 amps at 60 Hz, 0.5VA, Max. .5 Power factor lagging, AC voltmeter - unity power factor.

Note:
Severe-duty meters are available to meet CUL or UL 1437 requirements in 2-1/2in - 4-1/2in sizes.

Three Mounting Types Available in Stylist Series: Rear Panel Window Mount, Front of Panel Surface Mount, Rear Panel Surface Mount Available with Optional Bezel

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters.Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanism
 
 Price: $63.00
Yokogawa 254230PKPK - AC VOLTS - RETIFIED Rating- 0-150 vV/ACScale- 0-150Legend- AC VOLTS - Product Image

Yokogawa 254230PKPK - AC VOLTS - RETIFIED

Rating- 0-150 vV/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $71.00
Yokogawa 254337PNPN - AC VOLT EXPANDED SCALERating- 110-130 V/ACScale- 110-130Legend- AC VOLTS - Product Image

Yokogawa 254337PNPN - AC VOLT EXPANDED SCALE

Rating- 110-130 V/AC
Scale- 110-130
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $150.00
Yokogawa 254337RTRT - AC VOLT EXPANDED SCALERating- 220-260 V/ACScale- 220-260Legend- AC VOLTS - Product Image

Yokogawa 254337RTRT - AC VOLT EXPANDED SCALE

Rating- 220-260 V/AC
Scale- 220-260
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $150.00
Yokogawa 254338NNNN - DC VOLT EXPANDED SCALERating- 24-30 V/DCScale- 24-30Legend- DC VOLTS - Product Image

Yokogawa 254338NNNN - DC VOLT EXPANDED SCALE

Rating- 24-30 V/DC
Scale- 24-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $150.00
Yokogawa 254338RTRT - DC VOLT EXPANDED SCALERating- 220-260 V/DCScale- 220-260Legend- DC VOLTS - Product Image

Yokogawa 254338RTRT - DC VOLT EXPANDED SCALE

Rating- 220-260 V/DC
Scale- 220-260
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $150.00
Yokogawa 254437PNPN - AC VOLT EXPANDED SCALERating- 110-130 V/ACScale- 110-130Legend- AC VOLTS - Product Image

Yokogawa 254437PNPN - AC VOLT EXPANDED SCALE

Rating- 110-130 V/AC
Scale- 110-130
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $152.00
Yokogawa 254437PTPT - AC VOLT EXPANDED SCALERating- 105-125 V/ACScale- 105-125Legend- AC VOLTS - Product Image

Yokogawa 254437PTPT - AC VOLT EXPANDED SCALE

Rating- 105-125 V/AC
Scale- 105-125
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $152.00
Yokogawa 254438NNNN - DC VOLT EXPANDED SCALERating- 24-30 V/DCScale- 24-30Legend- DC VOLTS - Product Image

Yokogawa 254438NNNN - DC VOLT EXPANDED SCALE

Rating- 24-30 V/DC
Scale- 24-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $152.00
Yokogawa 254438PNPN - DC VOLT EXPANDED SCALERating- 110-130 V/DCScale- 110-130Legend- DC VOLTS - Product Image

Yokogawa 254438PNPN - DC VOLT EXPANDED SCALE

Rating- 110-130 V/DC
Scale- 110-130
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $152.00
Yokogawa 254438RTRT - DC VOLT EXPANDED SCALERating- 220-260 V/DCScale- 220-260Legend- DC VOLTS - Product Image

Yokogawa 254438RTRT - DC VOLT EXPANDED SCALE

Rating- 220-260 V/DC
Scale- 220-260
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary; 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.40in on the 1-1/2in model
2.06in on the 2-1/2in model
2.88in on the 3-1/2in model
3.93in on the 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 Vrms Hi-pot, 1-1/2in-1500 Vrms Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va, Max. 0.5 power-factor lagging at 60 Hz. AC voltmeter - unity power factor.

Response Time: 3 seconds (max.) for 2-1/2in, 3-1/2in, 4-1/2in size for microammeters; 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes:
Pivot & jewel instruments are not available in 1-1/2in size.
Severe-duty meters are available to meet CSA, UL 1437 and IEC 144 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. IEC version is not offered in 1-1/2in and 4-1/2in. To order, add /CUL, /UL or IEC after catalog number, or contact factory.
For ratings and scales not listed contact factory.

Dust Resistant Construction. YOKOGAWA Big Look panel meters, except 1-1/2in, feature gasketed construction to seal out dust and other air-suspended damaging particles. Application is ideal for adverse environments. Special dust resistant features are included on all YOKOGAWA New Big Look meters (except 1-1/2in). For more severe applications, to meet UL-1437 or IEC 144 requirements, other models are also available upon request.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application... and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Gasket Sealing Design Establishes A New Industry Standard: Dust resistant construction is now a standard feature of all New Big Look panel meters 2-1/2in - 4-1/2in only. YOKOGAWAs unique gasket sealing design eliminates the need for a crimped bezel, providing for quick modification and scale changes while maintaining the integrity of the meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.
Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.
Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Conduit Mounting Case - 2-1/2-inch New Big Look Meter: Available only for 2-1/2-inch Type 250 panel meters, for indoor or outdoor use, the conduitmounted case provides protection to the meter under severe environmental conditions. The conduit case is both sealed and weatherproof and is pre-drilled, ready for mounting of separately ordered panel meters.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $152.00
Yokogawa 255230PKPK - AC VOLTS - RETIFIED Rating- 0-150 vV/ACScale- 0-150Legend- AC VOLTS - Product Image

Yokogawa 255230PKPK - AC VOLTS - RETIFIED

Rating- 0-150 vV/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $71.00
Yokogawa 255337PNPN - AC VOLT EXPANDED SCALERating- 110-130 V/ACScale- 110-130Legend- AC VOLTS - Product Image

Yokogawa 255337PNPN - AC VOLT EXPANDED SCALE

Rating- 110-130 V/AC
Scale- 110-130
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $150.00
Yokogawa 255337RTRT - AC VOLT EXPANDED SCALERating- 220-260 V/ACScale- 220-260Legend- AC VOLTS - Product Image

Yokogawa 255337RTRT - AC VOLT EXPANDED SCALE

Rating- 220-260 V/AC
Scale- 220-260
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $150.00
Yokogawa 255338NNNN - DC VOLT EXPANDED SCALERating- 24-30 V/DCScale- 24-30Legend- DC VOLTS - Product Image

Yokogawa 255338NNNN - DC VOLT EXPANDED SCALE

Rating- 24-30 V/DC
Scale- 24-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $150.00
Yokogawa 255338RTRT - DC VOLT EXPANDED SCALERating- 220-260 V/DCScale- 220-260Legend- DC VOLTS - Product Image

Yokogawa 255338RTRT - DC VOLT EXPANDED SCALE

Rating- 220-260 V/DC
Scale- 220-260
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $150.00
Yokogawa 255437PNPN - AC VOLT EXPANDED SCALERating- 110-130 V/ACScale- 110-130Legend- AC VOLTS - Product Image

Yokogawa 255437PNPN - AC VOLT EXPANDED SCALE

Rating- 110-130 V/AC
Scale- 110-130
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $152.00
Yokogawa 255437PTPT - AC VOLT EXPANDED SCALERating- 105-125 V/ACScale- 105-125Legend- AC VOLTS - Product Image

Yokogawa 255437PTPT - AC VOLT EXPANDED SCALE

Rating- 105-125 V/AC
Scale- 105-125
Legend- AC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $152.00
Yokogawa 255438NNNN - DC VOLT EXPANDED SCALERating- 24-30 V/DCScale- 24-30Legend- DC VOLTS - Product Image

Yokogawa 255438NNNN - DC VOLT EXPANDED SCALE

Rating- 24-30 V/DC
Scale- 24-30
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $152.00
Yokogawa 255438PNPN - DC VOLT EXPANDED SCALERating- 110-130 V/DCScale- 110-130Legend- DC VOLTS - Product Image

Yokogawa 255438PNPN - DC VOLT EXPANDED SCALE

Rating- 110-130 V/DC
Scale- 110-130
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $152.00
Yokogawa 255438RTRT - DC VOLT EXPANDED SCALERating- 220-260 V/DCScale- 220-260Legend- DC VOLTS - Product Image

Yokogawa 255438RTRT - DC VOLT EXPANDED SCALE

Rating- 220-260 V/DC
Scale- 220-260
Legend- DC VOLTS

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications

 
 Price: $152.00
Yokogawa 251240LSMT - AC AMMETER Rating- 0-5 A/ACScale- 0-10Legend- AC AMPERES - Product Image

Yokogawa 251240LSMT - AC AMMETER

Rating- 0-5 A/AC
Scale- 0-10
Legend- AC AMPERES

Manufacture: Yokogawa

SPECIFICATIONS:
Accuracy: All DC and AC iron-vane; +-2% of full-scale, AC rectifier type; +-3% of full scale (with 60 Hz sine wave at 25 degrees C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 20 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters; +-.5% of full scale value.
ANSI Specification: All meters meet ANSI Specifications C-39.1.

Overload: Voltmeters (AC and DC) - 50% momentary, 20% sustained. Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of .5 second with a 1 minute interval between successive applications; sustained: 20% for six hours.
Scale Data: 90 degree rotation.
Scale Length:
1.50in on 1-1/2in model
2.06in on 2-1/2in model
2.88in on 3-1/2in model
3.93in on 4-1/2in model

Insulation Level: All meters (except 1-1/2in), 2600 VRMS Hi-pot, 1-1/2in-1500 VRMS Hi-pot.

Burden Data: AC ammeter-5 amps, 0.5 va max. 0.5 power-factor lagging, at 60 Hz. AC Voltmeter-unity power factor.
Response Time: 3 seconds (max.) for 2-1/in, 3-1/2in, 4-1/2in size for microammeters: 2 seconds (max.) for all other DC ratings, and 2.5 seconds (max.) for AC ratings.

Overshoot: Maximum of 40% overshoot.

Notes: Severe-duty meters are available to meet UL 1437 requirements. UL/CUL version, with flame retardant window and base, is not offered in 1-1/2in. To order, add /UL or /CUL after catalog number, or contact factory. For ratings and scales not listed contact factory.

Back-Of-Panel Mounting For Horizon Line: Horizon Line panel meters can be mounted either behind or in front of the panel. Behind-panel mounting is easy. . . just remove snap-off mask and mount. No special mounting hardware or bezel is required. This design feature improves panel appearance . . . saves time and money. When illuminated scales are required, simply position light source as shown, or in any suitable position along the edge of the instrument.

Clean, Readable Case Design Provides Extra Safety:
YOKOGAWAs brand New Big Look and Horizon Line panel meters are designed to provide attractive styling, quick, sure readability for any application . . . and a built in safety feature to help you meet national safety requirements. If you must remove the acrylic cover, you have to remove the instrument itself from the panel in order to reach the special safety screws holding on the cover. Removing the meter prevents shock hazard. This safety feature is standard on all New Big Look and Horizon Line meters.

Taut Band: Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters. Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

Pivot and Jewel: In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for highvibration environments because of the mechanisms inherent stability and strength. Accuracy and repeatability are almost equal to the taut-bands, and good performance from the pivot and jewel construction is the reason for its long popularity. Dont specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meters ability to withstand vibration.

High-Sensitivity DC Voltmeters: Standard DC voltmeter sensitivity is 1000 ohms/volt. Expressed differently, 1000 ohms/volt sensitivity means that the meter draws approximately one milliamp full-scale current.

Occasionally lower current drains are necessary, hence higher sensitivities may be required. The table below compares available sensitivities, maximum self-contained voltages, and approximate full-scale currents. The voltage range could be extended by using external resistors.

Expanded-Scale Voltmeters: For very close monitoring of voltages, Zener diode expanded scale voltmeters are available in 3-1/2- and 4-1/2-inch sizes for AC and DC ratings. Accuracy is +-0.5% of fullscale value. Standard voltage spans are listed in Ratings.

Expanded scale voltmeters can be furnished for any mid-span values from 12 to 300 volts. Minimum span is 16% of mid-span value.

Frequency Effect - AC Meters: Iron vane voltmeters are sensitive to frequency and should not be used on frequencies other than design frequency. (Standard voltmeters are calibrated at 60 Hertz. Used at 50 Hertz, accuracy becomes +-2-1/4%. There are also 150- and 300-volt ratings listed which are calibrated at 400 Hertz). For calibrations at frequencies other than 60 and 400 Hertz, refer to factory.

All Iron-vane ammeters (which produce a conventional scale distribution with divisions crowded in lower third of scale) from 10 milliamperes to 50 amperes are virtually unaffected by a change in frequency; e.g., a stock ammeter (calibrated at 60 Hertz) when used at 400 Hertz incurs an additional error of only .5 percent full-scale. If used on 1000 Hertz, the additional error is 4 percent. We recommend use of stock (60 Hertz) ammeters on any frequency in the range of 25 Hertz to 400 Hertz. For calibration at frequencies outside the 25-Hertz to 400-Hertz range, refer to factory or use a rectifier-type AC ammeter.

Rectifier-Type Meters: Rectifier-type meters differ from iron-vane mechanisms in that:
They provide a nominally linear (DC) scale rather than conventional iron-vane distribution which has a slight crowding at low end of scale.
AC current measurements of microamperes and milliamperes at minimum power consumption are permitted.
AC voltmeters of higher sensitivity (ohms/volt) than iron-vane types can be made.
Frequency response of rectifier type meters is essentially flat from 20 to 1,000 Hertz (1% effect from reference to 60 Hertz). Rectifier-type meters employ a full-wave rectifier and are available in ratings of 500microA to 30A.

Suppressed-Zero DC Meters: DC meters can be mechanically suppressed up to 20% of end-scale value. However, additional errors are introduced by suppressions (e.g. errors at 20% suppression = +-3% of end-scale). Many process transmitters in use today provide a 4-20mA signal (occasionally 10-50mA or 1-5mA) and require a suppressed-zero meter with operating zero set. These are known as live-zero and are standard.

Higher Accuracy: Standard calibration accuracy is +-2% of full scale. DC meters can be calibrated to +-1% of full scale as a special model in 3-1/2in and 4-1/2in with mirrored scale.

Data subject to change without notice.

Dimensional Drawings

General Specifications
 
 Price: $79.00
Simpson Catalog Number - 08010Model - 45AStyle - Round  0-150  ACV-RE3.5    RNDRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08010
Model - 45A
Style - Round
0-150 ACV-RE3.5 RND

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 08120Model - 47AStyle - Rectangular  0-1    ACV-RE3.5    RECTRating- 0-1 V/ACScale- 0-1Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08120
Model - 47A
Style - Rectangular
0-1 ACV-RE3.5 RECT

Rating- 0-1 V/AC
Scale- 0-1
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 08130Model - 47AStyle - Rectangular  0-3    ACV-RE3.5    RECTRating- 0-3 V/ACScale- 0-3Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08130
Model - 47A
Style - Rectangular
0-3 ACV-RE3.5 RECT

Rating- 0-3 V/AC
Scale- 0-3
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 08180Model - 47AStyle - Rectangular  0-100  ACV-RE3.5    RECTRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08180
Model - 47A
Style - Rectangular
0-100 ACV-RE3.5 RECT

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 08190Model - 47AStyle - Rectangular  0-150  ACV-RE3.5    RECTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08190
Model - 47A
Style - Rectangular
0-150 ACV-RE3.5 RECT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 08300Model - 49AStyle - Rectangular  0-1    ACV-RE4.5    RECTRating- 0-1 V/ACScale- 0-1Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08300
Model - 49A
Style - Rectangular
0-1 ACV-RE4.5 RECT

Rating- 0-1 V/AC
Scale- 0-1
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 08310Model - 49AStyle - Rectangular  0-3    ACV-RE4.5    RECTRating- 0-3 V/ACScale- 0-3Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08310
Model - 49A
Style - Rectangular
0-3 ACV-RE4.5 RECT

Rating- 0-3 V/AC
Scale- 0-3
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 08320Model - 49AStyle - Rectangular  0-5    ACV-RE4.5 UL RECTRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08320
Model - 49A
Style - Rectangular
0-5 ACV-RE4.5 UL RECT

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 08330Model - 49AStyle - Rectangular  0-10   ACV-RE4.5    RECTRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08330
Model - 49A
Style - Rectangular
0-10 ACV-RE4.5 RECT

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 08340Model - 49AStyle - Rectangular  0-15   ACV-RE4.5    RECTRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08340
Model - 49A
Style - Rectangular
0-15 ACV-RE4.5 RECT

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 08350Model - 49AStyle - Rectangular  0-50   ACV-RE4.5    RECTRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08350
Model - 49A
Style - Rectangular
0-50 ACV-RE4.5 RECT

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 08360Model - 49AStyle - Rectangular  0-100  ACV-RE4.5    RECTRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08360
Model - 49A
Style - Rectangular
0-100 ACV-RE4.5 RECT

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 08370Model - 49AStyle - Rectangular  0-150  ACV-RE4.5    RECTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08370
Model - 49A
Style - Rectangular
0-150 ACV-RE4.5 RECT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 08371Model - 49AStyle - Rectangular  0-300  ACV-RE4.5    RECTRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08371
Model - 49A
Style - Rectangular
0-300 ACV-RE4.5 RECT

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 08410Model - 55MDStyle - Round 0-5    ACV   3.5 UL RNDRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08410
Model - 55MD
Style - Round
0-5 ACV 3.5 UL RND

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 08420Model - 55MDStyle - Round 0-10   ACV   3.5 UL RNDRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08420
Model - 55MD
Style - Round
0-10 ACV 3.5 UL RND

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 08430Model - 55MDStyle - Round 0-15   ACV   3.5 UL RNDRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08430
Model - 55MD
Style - Round
0-15 ACV 3.5 UL RND

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 08440Model - 55MDStyle - Round 0-25   ACV   3.5 UL RNDRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08440
Model - 55MD
Style - Round
0-25 ACV 3.5 UL RND

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 08450Model - 55MDStyle - Round 0-50   ACV   3.5 UL RNDRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08450
Model - 55MD
Style - Round
0-50 ACV 3.5 UL RND

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 08460Model - 55MDStyle - Round 0-100  ACV   3.5 UL RNDRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08460
Model - 55MD
Style - Round
0-100 ACV 3.5 UL RND

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $150.00
Simpson Catalog Number - 08470Model - 55MDStyle - Round 0-150  ACV   3.5 UL RNDRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08470
Model - 55MD
Style - Round
0-150 ACV 3.5 UL RND

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 08480Model - 55MDStyle - Round 0-250  ACV   3.5 UL RNDRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08480
Model - 55MD
Style - Round
0-250 ACV 3.5 UL RND

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 08490Model - 55MDStyle - Round 0-300  ACV   3.5 UL RNDRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08490
Model - 55MD
Style - Round
0-300 ACV 3.5 UL RND

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 08500Model - 55MDStyle - Round 0-500  ACV   3.5 UL RNDRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08500
Model - 55MD
Style - Round
0-500 ACV 3.5 UL RND

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 08510Model - 55MDStyle - Round 0-750  ACV   3.5 UL RNDRating- 0-750 V/ACScale- 0-750Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08510
Model - 55MD
Style - Round
0-750 ACV 3.5 UL RND

Rating- 0-750 V/AC
Scale- 0-750
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $210.00
Simpson Catalog Number - 08540Model - 57MDStyle - Rectangular 0-3    ACV   3.5 UL RECTRating- 0-3 V/ACScale- 0-3Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08540
Model - 57MD
Style - Rectangular
0-3 ACV 3.5 UL RECT

Rating- 0-3 V/AC
Scale- 0-3
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 08550Model - 57MDStyle - Rectangular 0-5    ACV   3.5 UL RECTRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08550
Model - 57MD
Style - Rectangular
0-5 ACV 3.5 UL RECT

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 08566Model - 57MDStyle - Rectangular 0-10   ACV   3.5 UL RECTRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08566
Model - 57MD
Style - Rectangular
0-10 ACV 3.5 UL RECT

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 08580Model - 57MDStyle - Rectangular 0-15   ACV   3.5 UL RECTRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08580
Model - 57MD
Style - Rectangular
0-15 ACV 3.5 UL RECT

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 08599Model - 57MDStyle - Rectangular 0-25   ACV   3.5 UL RECTRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08599
Model - 57MD
Style - Rectangular
0-25 ACV 3.5 UL RECT

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 08610Model - 57MDStyle - Rectangular 0-50   ACV   3.5 UL RECTRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08610
Model - 57MD
Style - Rectangular
0-50 ACV 3.5 UL RECT

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 08620Model - 57MDStyle - Rectangular 0-100  ACV   3.5 UL RECTRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08620
Model - 57MD
Style - Rectangular
0-100 ACV 3.5 UL RECT

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 08630Model - 57MDStyle - Rectangular 0-150  ACV   3.5 UL RECTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08630
Model - 57MD
Style - Rectangular
0-150 ACV 3.5 UL RECT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $147.00
Simpson Catalog Number - 08650Model - 57MDStyle - Rectangular 0-250  ACV   3.5 UL RECTRating- 0-250 VA/CScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08650
Model - 57MD
Style - Rectangular
0-250 ACV 3.5 UL RECT

Rating- 0-250 VA/C
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 08660Model - 57MDStyle - Rectangular 0-300  ACV   3.5 UL RECTRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08660
Model - 57MD
Style - Rectangular
0-300 ACV 3.5 UL RECT

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 08680Model - 57MDStyle - Rectangular 0-500  ACV   3.5 UL RECTRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08680
Model - 57MD
Style - Rectangular
0-500 ACV 3.5 UL RECT

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 08690Model - 57MDStyle - Rectangular 0-750  ACV   3.5 UL RECTRating- 0-750 V/ACScale- 0-750Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08690
Model - 57MD
Style - Rectangular
0-750 ACV 3.5 UL RECT

Rating- 0-750 V/AC
Scale- 0-750
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $205.00
Simpson Catalog Number - 08700Model - 57MDStyle - Rectangular 0-1000 ACV   3.5 UL RECTRating- 0-1000 V/ACScale- 0-1000Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08700
Model - 57MD
Style - Rectangular
0-1000 ACV 3.5 UL RECT

Rating- 0-1000 V/AC
Scale- 0-1000
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $210.00
Simpson Catalog Number - 08710Model - 59MDStyle - Rectangular 0-1.5  ACV   4.5 UL RECTRating- 0-1.5 V/ACScale- 0-1.5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08710
Model - 59MD
Style - Rectangular
0-1.5 ACV 4.5 UL RECT

Rating- 0-1.5 V/AC
Scale- 0-1.5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 08720Model - 59MDStyle - Rectangular 0-3    ACV   4.5 UL RECTRating- 0-3 V/ACScale- 0-3Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08720
Model - 59MD
Style - Rectangular
0-3 ACV 4.5 UL RECT

Rating- 0-3 V/AC
Scale- 0-3
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 08730Model - 59MDStyle - Rectangular 0-5    ACV   4.5 UL RECTRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08730
Model - 59MD
Style - Rectangular
0-5 ACV 4.5 UL RECT

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 08740Model - 59MDStyle - Rectangular 0-10   ACV   4.5 UL RECTRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08740
Model - 59MD
Style - Rectangular
0-10 ACV 4.5 UL RECT

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 08750Model - 59MDStyle - Rectangular 0-15   ACV   4.5 UL RECTRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08750
Model - 59MD
Style - Rectangular
0-15 ACV 4.5 UL RECT

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 08760Model - 59MDStyle - Rectangular 0-25   ACV   4.5 UL RECTRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08760
Model - 59MD
Style - Rectangular
0-25 ACV 4.5 UL RECT

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 08770Model - 59MDStyle - Rectangular 0-50   ACV   4.5 UL RECTRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08770
Model - 59MD
Style - Rectangular
0-50 ACV 4.5 UL RECT

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 08780Model - 59MDStyle - Rectangular 0-100  ACV   4.5 UL RECTRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08780
Model - 59MD
Style - Rectangular
0-100 ACV 4.5 UL RECT

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $107.52
Simpson Catalog Number - 08790Model - 59MDStyle - Rectangular 0-150  ACV   4.5 UL RECTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08790
Model - 59MD
Style - Rectangular
0-150 ACV 4.5 UL RECT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $156.00
Simpson Catalog Number - 08800Model - 59MDStyle - Rectangular 0-250  ACV   4.5 UL RECTRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08800
Model - 59MD
Style - Rectangular
0-250 ACV 4.5 UL RECT

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $156.00
Simpson Catalog Number - 08810Model - 59MDStyle - Rectangular 0-300  ACV   4.5 UL RECTRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08810
Model - 59MD
Style - Rectangular
0-300 ACV 4.5 UL RECT

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $156.00
Simpson Catalog Number - 08820Model - 59MDStyle - Rectangular 0-500  ACV   4.5 UL RECTRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08820
Model - 59MD
Style - Rectangular
0-500 ACV 4.5 UL RECT

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $205.00
Simpson Catalog Number - 08830Model - 59MDStyle - Rectangular 0-750  ACV   4.5 UL RECTRating- 0-750 V/ACScale- 0-750Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08830
Model - 59MD
Style - Rectangular
0-750 ACV 4.5 UL RECT

Rating- 0-750 V/AC
Scale- 0-750
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $225.00
Simpson Catalog Number - 08840Model - 59MDStyle - Rectangular 0-1000 ACV   4.5 UL RECTRating- 0-1000 V/ACScale- 0-1000Legend- AC VOLTS - Product Image

Simpson Catalog Number - 08840
Model - 59MD
Style - Rectangular
0-1000 ACV 4.5 UL RECT

Rating- 0-1000 V/AC
Scale- 0-1000
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $217.00
Simpson Catalog Number - 09290Model - 155MDStyle - Round0-50   ACV   2.5 UL RNDRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09290
Model - 155MD
Style - Round
0-50 ACV 2.5 UL RND

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 09310Model - 155MDStyle - Round0-150  ACV   2.5 UL RNDRating- 0-150  V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09310
Model - 155MD
Style - Round
0-150 ACV 2.5 UL RND

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 09320Model - 155MDStyle - Round0-250  ACV   2.5 UL RNDRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09320
Model - 155MD
Style - Round
0-250 ACV 2.5 UL RND

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09330Model - 155MDStyle - Round0-300  ACV   2.5 UL RNDRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09330
Model - 155MD
Style - Round
0-300 ACV 2.5 UL RND

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 09340Model - 155MDStyle - Round0-500  ACV   2.5 UL RNDRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09340
Model - 155MD
Style - Round
0-500 ACV 2.5 UL RND

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • 2% Full Scale Accuracy (3% for Rectifier)
  • Glass window for optimum viewing
  • Rugged black plastic case
  • Black spade-type pointer for easy distant reading


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 09390Model - 157MDStyle - Rectangular0-5    ACV   2.5 UL RECTRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09390
Model - 157MD
Style - Rectangular
0-5 ACV 2.5 UL RECT

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09400Model - 157MDStyle - Rectangular0-10   ACV   2.5 UL RECTRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09400
Model - 157MD
Style - Rectangular
0-10 ACV 2.5 UL RECT

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09420Model - 157MDStyle - Rectangular0-15   ACV   2.5 UL RECTRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09420
Model - 157MD
Style - Rectangular
0-15 ACV 2.5 UL RECT

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09440Model - 157MStyle - Rectangular 0-25   ACV   2.5 UL RECTRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09440
Model - 157M
Style - Rectangular
0-25 ACV 2.5 UL RECT

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09450Model - 157MDStyle - Rectangular0-50   ACV   2.5 UL RECTRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09450
Model - 157MD
Style - Rectangular
0-50 ACV 2.5 UL RECT

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09460Model - 157MDStyle - Rectangular0-100  ACV   2.5 UL RECTRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09460
Model - 157MD
Style - Rectangular
0-100 ACV 2.5 UL RECT

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09470Model - 157MDStyle - Rectangular0-150  ACV   2.5 UL RECTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09470
Model - 157MD
Style - Rectangular
0-150 ACV 2.5 UL RECT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 09490Model - 157  Style - Rectangular0-250  ACV   2.5 UL RECTRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09490
Model - 157
Style - Rectangular
0-250 ACV 2.5 UL RECT

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09500Model - 157MDStyle - Rectangular0-300  ACV   2.5 UL RECTRating- 0-300 VA/CScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09500
Model - 157MD
Style - Rectangular
0-300 ACV 2.5 UL RECT

Rating- 0-300 VA/C
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 09520Model - 157MDStyle - Rectangular0-500  ACV   2.5 UL RECTRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09520
Model - 157MD
Style - Rectangular
0-500 ACV 2.5 UL RECT

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Three Popular Sizes: 2-1/2", 3-1/2" and 4-1/2"
  • Distinctive Case Style
  • Glass Window
  • Phenolic Case
  • UL Recognized
  • Calibration not affected when mounted on steel


Product PDF
 
 Price: $121.88
Simpson Catalog Number - 09670Model - 1257MDStyle - Wide Vue0-10   ACV   2.5 UL WVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09670
Model - 1257MD
Style - Wide Vue
0-10 ACV 2.5 UL WV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09675Model - 1257MDStyle - Wide Vue0-15   ACV   2.5 UL WVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09675
Model - 1257MD
Style - Wide Vue
0-15 ACV 2.5 UL WV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09680Model - 1257MDStyle - Wide Vue0-25   ACV   2.5 UL WVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09680
Model - 1257MD
Style - Wide Vue
0-25 ACV 2.5 UL WV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09690Model - 1257MDStyle - Wide Vue0-50   ACV   2.5 UL WVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09690
Model - 1257MD
Style - Wide Vue
0-50 ACV 2.5 UL WV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $140.00
Simpson Catalog Number - 09695Model - 1257MDStyle - Wide Vue0-100  ACV   2.5 UL WVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09695
Model - 1257MD
Style - Wide Vue
0-100 ACV 2.5 UL WV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 09700Model - 1257MDStyle - Wide Vue0-150  ACV   2.5 UL WVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09700
Model - 1257MD
Style - Wide Vue
0-150 ACV 2.5 UL WV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 09705Model - 1257MDStyle - Wide Vue0-250  ACV   2.5 UL WVRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09705
Model - 1257MD
Style - Wide Vue
0-250 ACV 2.5 UL WV

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 09710Model - 1257MDStyle - Wide Vue0-300  ACV   2.5 UL WVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09710
Model - 1257MD
Style - Wide Vue
0-300 ACV 2.5 UL WV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 09715Model - 1257MDStyle - Wide Vue0-500  ACV   2.5 UL WVRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 09715
Model - 1257MD
Style - Wide Vue
0-500 ACV 2.5 UL WV

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 10015Model - 1247AStyle - Wide Vue0-5    ACV-RE2.5    WVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10015
Model - 1247A
Style - Wide Vue
0-5 ACV-RE2.5 WV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $172.00
Simpson Catalog Number - 10016Model - 1247AStyle - Wide Vue0-10  ACV-RE2.5    WVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10016
Model - 1247A
Style - Wide Vue
0-10 ACV-RE2.5 WV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $172.00
Simpson Catalog Number - 10017Model - 1247AStyle - Wide Vue0-150  ACV-RE2.5    WVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10017
Model - 1247A
Style - Wide Vue
0-150 ACV-RE2.5 WV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $101.17
Simpson Catalog Number - 10018Model - 1247AStyle - Wide Vue0-300  ACV-RE2.5    WVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10018
Model - 1247A
Style - Wide Vue
0-300 ACV-RE2.5 WV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $172.00
Simpson Catalog Number - 10020Model - 1347AStyle - Wide Vue0-5    ACV-RE3.5    WVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10020
Model - 1347A
Style - Wide Vue
0-5 ACV-RE3.5 WV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 10030Model - 1347AStyle - Wide Vue0-10   ACV-RE3.5    WVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10030
Model - 1347A
Style - Wide Vue
0-10 ACV-RE3.5 WV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 10040Model - 1347AStyle - Wide Vue0-15   ACV-RE3.5    WVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10040
Model - 1347A
Style - Wide Vue
0-15 ACV-RE3.5 WV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 10050Model - 1347AStyle - Wide Vue0-50   ACV-RE3.5    WVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10050
Model - 1347A
Style - Wide Vue
0-50 ACV-RE3.5 WV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 10060Model - 1347AStyle - Wide Vue0-150  ACV-RE3.5    WVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10060
Model - 1347A
Style - Wide Vue
0-150 ACV-RE3.5 WV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 10070Model - 1347AStyle - Wide Vue0-300  ACV-RE3.5    WVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10070
Model - 1347A
Style - Wide Vue
0-300 ACV-RE3.5 WV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 10090Model - 1349AStyle - Wide Vue0-5    ACV-RE4.5    WVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10090
Model - 1349A
Style - Wide Vue
0-5 ACV-RE4.5 WV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $205.00
Simpson Catalog Number - 10100Model - 1349AStyle - Wide Vue0-10   ACV-RE4.5    WVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10100
Model - 1349A
Style - Wide Vue
0-10 ACV-RE4.5 WV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $205.00
Simpson Catalog Number - 10110Model - 1349AStyle - Wide Vue0-15   ACV-RE4.5    WVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10110
Model - 1349A
Style - Wide Vue
0-15 ACV-RE4.5 WV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $205.00
Simpson Catalog Number - 10120Model - 1349AStyle - Wide Vue0-50   ACV-RE4.5    WVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10120
Model - 1349A
Style - Wide Vue
0-50 ACV-RE4.5 WV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $205.00
Simpson Catalog Number - 10130Model - 1349AStyle - Wide Vue0-150  ACV-RE4.5    WVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10130
Model - 1349A
Style - Wide Vue
0-150 ACV-RE4.5 WV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $205.00
Simpson Catalog Number - 10140Model - 1349AStyle - Wide Vue0-300  ACV-RE4.5    WVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10140
Model - 1349A
Style - Wide Vue
0-300 ACV-RE4.5 WV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $205.00
Simpson Catalog Number - 10160Model - 1357MDStyle - Wide Vue0-5    ACV   3.5 UL WVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10160
Model - 1357MD
Style - Wide Vue
0-5 ACV 3.5 UL WV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 10170Model - 1357MDStyle - Wide Vue0-10   ACV   3.5 UL WVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10170
Model - 1357MD
Style - Wide Vue
0-10 ACV 3.5 UL WV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 10180Model - 1357MDStyle - Wide Vue0-15   ACV   3.5 UL WVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10180
Model - 1357MD
Style - Wide Vue
0-15 ACV 3.5 UL WV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 10190Model -  1357MDStyle - Wide Vue0-25   ACV   3.5 UL WVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10190
Model - 1357MD
Style - Wide Vue
0-25 ACV 3.5 UL WV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 10200Model - 1357MDStyle - Wide Vue0-50   ACV   3.5 UL WVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10200
Model - 1357MD
Style - Wide Vue
0-50 ACV 3.5 UL WV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 10210Model - 1357MDStyle - Wide Vue0-100  ACV   3.5 UL WVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10210
Model - 1357MD
Style - Wide Vue
0-100 ACV 3.5 UL WV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $145.00
Simpson Catalog Number - 10220Model - 1357MDStyle - Wide Vue0-150  ACV   3.5 UL WVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10220
Model - 1357MD
Style - Wide Vue
0-150 ACV 3.5 UL WV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10230Model - 1357MDStyle - Wide Vue0-250  ACV   3.5 UL WVRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10230
Model - 1357MD
Style - Wide Vue
0-250 ACV 3.5 UL WV

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10240Model - 1357MDStyle - Wide Vue0-300  ACV   3.5 UL WVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10240
Model - 1357MD
Style - Wide Vue
0-300 ACV 3.5 UL WV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10250Model - 1357MDStyle - Wide Vue0-500  ACV   3.5 UL WVRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10250
Model - 1357MD
Style - Wide Vue
0-500 ACV 3.5 UL WV

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $195.00
Simpson Catalog Number - 10260Model - 1359MDStyle - Wide Vue0-5    ACV   4.5 UL WVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10260
Model - 1359MD
Style - Wide Vue
0-5 ACV 4.5 UL WV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10270Model - 1359MDStyle - Wide Vue0-10   ACV   4.5 UL WVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10270
Model - 1359MD
Style - Wide Vue
0-10 ACV 4.5 UL WV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10280Model - 1359MDStyle - Wide Vue0-15   ACV   4.5 UL WVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10280
Model - 1359MD
Style - Wide Vue
0-15 ACV 4.5 UL WV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10290Model - 1359MDStyle - Wide Vue0-25   ACV   4.5 UL WVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10290
Model - 1359MD
Style - Wide Vue
0-25 ACV 4.5 UL WV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10300Model - 1359MDStyle - Wide Vue0-50   ACV   4.5 UL WVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10300
Model - 1359MD
Style - Wide Vue
0-50 ACV 4.5 UL WV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10310Model - 1359MDStyle - Wide Vue0-100  ACV   4.5 UL WVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10310
Model - 1359MD
Style - Wide Vue
0-100 ACV 4.5 UL WV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10320Model - 1359MDStyle - Wide Vue0-150  ACV   4.5 UL WVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10320
Model - 1359MD
Style - Wide Vue
0-150 ACV 4.5 UL WV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10330Model - 1359MDStyle - Wide Vue0-250  ACV   4.5 UL WVRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10330
Model - 1359MD
Style - Wide Vue
0-250 ACV 4.5 UL WV

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10340Model - 1359MDStyle - Wide Vue0-300  ACV   4.5 UL WVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10340
Model - 1359MD
Style - Wide Vue
0-300 ACV 4.5 UL WV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 10350Model - 1359MDStyle - Wide Vue0-500  ACV   4.5 UL WVRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 10350
Model - 1359MD
Style - Wide Vue
0-500 ACV 4.5 UL WV

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear, acrylic window for wide angle visibility
  • Black spade pointer for easy distant viewing
  • UL Recognized
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2", and 4-1/2"


Product PDF
 
 Price: $206.00
Simpson Catalog Number - 15060Model - 553MDStyle - Designer0-150  ACV   3.5    DESRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 15060
Model - 553MD
Style - Designer
0-150 ACV 3.5 DES

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clean, Uncluttered Look
  • Maximum Readability in Minimum Required Height
  • UL Recognized
  • Phenolic Cases
  • Large Glass Windows
  • Two Popular Sizes: 3-1/2" and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 15061Model - 553MDStyle - Designer0-250  ACV   3.5    DESRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 15061
Model - 553MD
Style - Designer
0-250 ACV 3.5 DES

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clean, Uncluttered Look
  • Maximum Readability in Minimum Required Height
  • UL Recognized
  • Phenolic Cases
  • Large Glass Windows
  • Two Popular Sizes: 3-1/2" and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 15062Model - 553MDStyle - Designer0-300  ACV   3.5    DESRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 15062
Model - 553MD
Style - Designer
0-300 ACV 3.5 DES

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clean, Uncluttered Look
  • Maximum Readability in Minimum Required Height
  • UL Recognized
  • Phenolic Cases
  • Large Glass Windows
  • Two Popular Sizes: 3-1/2" and 4-1/2"


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 15130Model - 554MDStyle - Designer0-150  ACV   4.5    DESRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 15130
Model - 554MD
Style - Designer
0-150 ACV 4.5 DES

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clean, Uncluttered Look
  • Maximum Readability in Minimum Required Height
  • UL Recognized
  • Phenolic Cases
  • Large Glass Windows
  • Two Popular Sizes: 3-1/2" and 4-1/2"


Product PDF
 
 Price: $170.00
Simpson Catalog Number - 15131Model - 554MDStyle - Designer0-250  ACV   4.5    DESRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 15131
Model - 554MD
Style - Designer
0-250 ACV 4.5 DES

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clean, Uncluttered Look
  • Maximum Readability in Minimum Required Height
  • UL Recognized
  • Phenolic Cases
  • Large Glass Windows
  • Two Popular Sizes: 3-1/2" and 4-1/2"


Product PDF
 
 Price: $170.00
Simpson Catalog Number - 15132Model - 554MDStyle - Designer0-300  ACV   4.5    DESRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 15132
Model - 554MD
Style - Designer
0-300 ACV 4.5 DES

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clean, Uncluttered Look
  • Maximum Readability in Minimum Required Height
  • UL Recognized
  • Phenolic Cases
  • Large Glass Windows
  • Two Popular Sizes: 3-1/2" and 4-1/2"


Product PDF
 
 Price: $170.00
Simpson Catalog Number - 16160Model - 3344AStyle - Rugged SealS-0-150  ACV-RE4.5    SEALRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 16160
Model - 3344A
Style - Rugged Seal
S-0-150 ACV-RE4.5 SEAL

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $265.00
Simpson Catalog Number - 16165Model - 3344AStyle - Rugged SealS-0-300  ACV-RE4.5    SEALRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 16165
Model - 3344A
Style - Rugged Seal
S-0-300 ACV-RE4.5 SEAL

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $265.00
Simpson Catalog Number - 17460Model - 2142AStyle - Century0-5    ACV-RE2.5    CENTRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17460
Model - 2142A
Style - Century
0-5 ACV-RE2.5 CENT

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $170.00
Simpson Catalog Number - 17462Model - 2142AStyle - Century0-150  ACV-RE2.5    CENTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17462
Model - 2142A
Style - Century
0-150 ACV-RE2.5 CENT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $170.00
Simpson Catalog Number - 17542Model - 2143AStyle - Century0-5    ACV-RE3.5    CENTRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17542
Model - 2143A
Style - Century
0-5 ACV-RE3.5 CENT

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 17543Model - 2143AStyle - Century0-10   ACV-RE3.5    CENTRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17543
Model - 2143A
Style - Century
0-10 ACV-RE3.5 CENT

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 17544Model - 2143AStyle - Century0-15   ACV-RE3.5    CENTRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17544
Model - 2143A
Style - Century
0-15 ACV-RE3.5 CENT

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 17545Model - 2143AStyle - Century0-50   ACV-RE3.5    CENTRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17545
Model - 2143A
Style - Century
0-50 ACV-RE3.5 CENT

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 17546Model - 2143AStyle - Century0-150  ACV-RE3.5    CENTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17546
Model - 2143A
Style - Century
0-150 ACV-RE3.5 CENT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $190.00
Simpson Catalog Number - 17640Model - 2144AStyle - Century0-5    ACV-RE4.5    CENTRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17640
Model - 2144A
Style - Century
0-5 ACV-RE4.5 CENT

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $210.00
Simpson Catalog Number - 17641Model - 2144AStyle - Century0-10   ACV-RE4.5    CENTRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17641
Model - 2144A
Style - Century
0-10 ACV-RE4.5 CENT

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $210.00
Simpson Catalog Number - 17642Model - 2144AStyle - Century0-15   ACV-RE4.5    CENTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17642
Model - 2144A
Style - Century
0-15 ACV-RE4.5 CENT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $210.00
Simpson Catalog Number - 17643Model - 2144AStyle - Century0-50   ACV-RE4.5    CENTRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17643
Model - 2144A
Style - Century
0-50 ACV-RE4.5 CENT

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $210.00
Simpson Catalog Number - 17644Model - 2144AStyle - Century0-150  ACV-RE4.5    CENTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17644
Model - 2144A
Style - Century
0-150 ACV-RE4.5 CENT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $210.00
Simpson Catalog Number - 17645Model - 2144AStyle - Century0-300  ACV-RE4.5    CENTRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17645
Model - 2144A
Style - Century
0-300 ACV-RE4.5 CENT

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $210.00
Simpson Catalog Number - 17685Model - 2152MDStyle - Century0-10   ACV   2.5 UL CENTRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17685
Model - 2152MD
Style - Century
0-10 ACV 2.5 UL CENT

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $146.00
Simpson Catalog Number - 17686Model - 2152MDStyle - Century0-15   ACV   2.5 UL CENTRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17686
Model - 2152MD
Style - Century
0-15 ACV 2.5 UL CENT

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $146.00
Simpson Catalog Number - 17687Model - 2152MDStyle - Century0-25   ACV   2.5 UL CENTRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17687
Model - 2152MD
Style - Century
0-25 ACV 2.5 UL CENT

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $146.00
Simpson Catalog Number - 17688Model - 2152MDStyle - Century0-50   ACV   2.5 UL CENTRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17688
Model - 2152MD
Style - Century
0-50 ACV 2.5 UL CENT

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $146.00
Simpson Catalog Number - 17690Model - 2152MDStyle - Century0-150  ACV   2.5 UL CENTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17690
Model - 2152MD
Style - Century
0-150 ACV 2.5 UL CENT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $146.00
Simpson Catalog Number - 17691Model - 2152MDStyle - Century0-250  ACV   2.5 UL CENTRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17691
Model - 2152MD
Style - Century
0-250 ACV 2.5 UL CENT

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $146.00
Simpson Catalog Number - 17692Model - 2152MDStyle - Century0-300  ACV   2.5 UL CENTRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17692
Model - 2152MD
Style - Century
0-300 ACV 2.5 UL CENT

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $146.00
Simpson Catalog Number - 17725Model - 2153MDStyle - Century0-5    ACV   3.5 UL CENTRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17725
Model - 2153MD
Style - Century
0-5 ACV 3.5 UL CENT

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $150.00
Simpson Catalog Number - 17726Model - 2153MDStyle - Century0-10   ACV   3.5 UL CENTRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17726
Model - 2153MD
Style - Century
0-10 ACV 3.5 UL CENT

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $150.00
Simpson Catalog Number - 17727Model - 2153MDStyle - Century0-15   ACV   3.5 UL CENTRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17727
Model - 2153MD
Style - Century
0-15 ACV 3.5 UL CENT

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $150.00
Simpson Catalog Number - 17728Model - 2153MDStyle - Century0-25   ACV   3.5 UL CENTRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17728
Model - 2153MD
Style - Century
0-25 ACV 3.5 UL CENT

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $150.00
Simpson Catalog Number - 17729Model - 2153MDStyle - Century0-50   ACV   3.5 UL CENTRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17729
Model - 2153MD
Style - Century
0-50 ACV 3.5 UL CENT

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $150.00
Simpson Catalog Number - 17730Model - 2153MDStyle - Century0-100  ACV   3.5 UL CENTRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17730
Model - 2153MD
Style - Century
0-100 ACV 3.5 UL CENT

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $150.00
Simpson Catalog Number - 17731Model - 2153MDStyle - Century0-150  ACV   3.5 UL CENTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17731
Model - 2153MD
Style - Century
0-150 ACV 3.5 UL CENT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 17732Model - 2153MDStyle - Century0-250  ACV   3.5 UL CENTRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17732
Model - 2153MD
Style - Century
0-250 ACV 3.5 UL CENT

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 17733Model - 2153MDStyle - Century0-300  ACV   3.5 UL CENTRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17733
Model - 2153MD
Style - Century
0-300 ACV 3.5 UL CENT

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $155.00
Simpson Catalog Number - 17734Model - 2153MDStyle - Century0-500  ACV   3.5 UL CENTRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17734
Model - 2153MD
Style - Century
0-500 ACV 3.5 UL CENT

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $195.00
Simpson Catalog Number - 17771Model - 2154MDStyle - Century0-10   ACV   4.5 UL CENTRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17771
Model - 2154MD
Style - Century
0-10 ACV 4.5 UL CENT

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 17772Model - 2154MDStyle - Century0-15   ACV   4.5 UL CENTRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17772
Model - 2154MD
Style - Century
0-15 ACV 4.5 UL CENT

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 17773Model - 2154MDStyle - Century0-25   ACV   4.5 UL CENTRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17773
Model - 2154MD
Style - Century
0-25 ACV 4.5 UL CENT

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 17774Model - 2154MDStyle - Century0-50   ACV   4.5 UL CENTRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17774
Model - 2154MD
Style - Century
0-50 ACV 4.5 UL CENT

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 17775Model - 2154MDStyle - Century0-100  ACV   4.5 UL CENTRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17775
Model - 2154MD
Style - Century
0-100 ACV 4.5 UL CENT

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $160.00
Simpson Catalog Number - 17776Model - 2154MDStyle - Century0-150  ACV   4.5 UL CENTRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17776
Model - 2154MD
Style - Century
0-150 ACV 4.5 UL CENT

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $170.00
Simpson Catalog Number - 17777Model - 2154MDStyle - Century0-250  ACV   4.5 UL CENTRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17777
Model - 2154MD
Style - Century
0-250 ACV 4.5 UL CENT

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $170.00
Simpson Catalog Number - 17778Model - 2154MDStyle - Century0-300  ACV   4.5 UL CENTRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17778
Model - 2154MD
Style - Century
0-300 ACV 4.5 UL CENT

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $170.00
Simpson Catalog Number - 17779Model - 2154MDStyle - Century0-500  ACV   4.5 UL CENTRating- 0-500 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17779
Model - 2154MD
Style - Century
0-500 ACV 4.5 UL CENT

Rating- 0-500 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $210.00
Simpson Catalog Number - 17915Model - 2143LStyle - Century0-30   ACV-RE3.5    250DGRating- 0-30 V/ACScale- 0-30Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17915
Model - 2143L
Style - Century
0-30 ACV-RE3.5 250DG

Rating- 0-30 V/AC
Scale- 0-30
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $325.00
Simpson Catalog Number - 17916Model - 2143LStyle - Century0-150  ACV-RE3.5    250DGRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17916
Model - 2143L
Style - Century
0-150 ACV-RE3.5 250DG

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $325.00
Simpson Catalog Number - 17917Model - 2143LStyle - Century0-300  ACV-RE3.5    250DGRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17917
Model - 2143L
Style - Century
0-300 ACV-RE3.5 250DG

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $325.00
Simpson Catalog Number - 17978Model - 2543LStyle - Century0-150  ACV-RE3.5    250DGRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17978
Model - 2543L
Style - Century
0-150 ACV-RE3.5 250DG

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $425.00
Simpson Catalog Number - 17979Model - 2543LStyle - Century0-300  ACV-RE3.5    250DGRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17979
Model - 2543L
Style - Century
0-300 ACV-RE3.5 250DG

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $410.00
Simpson Catalog Number - 17988Model - 2544LStyle - Century0-150  ACV-RE4.5    250DGRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17988
Model - 2544L
Style - Century
0-150 ACV-RE4.5 250DG

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $415.00
Simpson Catalog Number - 17989Model - 2544LStyle - Century0-300  ACV-RE4.5    250DGRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17989
Model - 2544L
Style - Century
0-300 ACV-RE4.5 250DG

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $415.00
Simpson Catalog Number - 17990Model - 2543LStyle - Century0-10   ACV-RE3.5    250DGRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17990
Model - 2543L
Style - Century
0-10 ACV-RE3.5 250DG

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $425.00
Simpson Catalog Number - 17995Model - 2544LStyle - Century0-10   ACV-RE4.5    250DGRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 17995
Model - 2544L
Style - Century
0-10 ACV-RE4.5 250DG

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • UL Recognized
  • Phenolic Cases
  • Rectifier or Iron-Vane Type Movements
  • Large Glass Windows
  • Four Popular Sizes: 1-1/2", 2-1/2", 3-1/2" and 4-1/2"


Product PDF
 
 Price: $415.00
Simpson Catalog Number - 21635Model - 3343AIXA Style - Rugged Seal0-10   ACV   3.5    DSPRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 21635
Model - 3343AIXA
Style - Rugged Seal
0-10 ACV 3.5 DSP

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $930.00
Simpson Catalog Number - 21636Model - 3343AIXA Style - Rugged Seal0-150  ACV   3.5    DSPRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 21636
Model - 3343AIXA
Style - Rugged Seal
0-150 ACV 3.5 DSP

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $925.00
Simpson Catalog Number - 21637Model - 3344AIXA Style - Rugged Seal0-5    ACA   4.5    DSPRating- 0-5 A/ACScale- 0-5Legend- AC AMPERES - Product Image

Simpson Catalog Number - 21637
Model - 3344AIXA
Style - Rugged Seal
0-5 ACA 4.5 DSP

Rating- 0-5 A/AC
Scale- 0-5
Legend- AC AMPERES

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $1,000.00
Simpson Catalog Number - 21639Model - 3344AIXAStyle - Rugged Seal0-10   ACV   4.5    DSPRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 21639
Model - 3344AIXA
Style - Rugged Seal
0-10 ACV 4.5 DSP

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $945.00
Simpson Catalog Number - 21640Model - 3344AIXAStyle - Rugged Seal0-150  ACV   4.5    DSPRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - 21640
Model - 3344AIXA
Style - Rugged Seal
0-150 ACV 4.5 DSP

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $945.00
Simpson Catalog Number - 21641Model - 3343AIXA Style - Rugged Seal0-300  ACV   3.5    DSPRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 21641
Model - 3343AIXA
Style - Rugged Seal
0-300 ACV 3.5 DSP

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $925.00
Simpson Catalog Number - 21642Model - 3344AIXAStyle - Rugged Seal0-300  ACV   4.5    DSPRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - 21642
Model - 3344AIXA
Style - Rugged Seal
0-300 ACV 4.5 DSP

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $945.00
Simpson Catalog Number - 21644Model - 3344AIXAStyle - Rugged Seal0-10   ACV   4.5    DSPRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - 21644
Model - 3344AIXA
Style - Rugged Seal
0-10 ACV 4.5 DSP

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Rugged Metal Case for Rigorous Environments
  • Commercially Sealed, Moisture and Dust Proof
  • Calibration not Affected by Steel Panel Mounting
  • O-Ring Sealed Zero Adjust and Electrical Terminals
  • Three Convenient Sizes: 3-1/2", 4-1/2", and 4x6"


Product PDF
 
 Price: $975.00
Simpson Catalog Number - TV1RVV005Model -  TV1Style - True Vue     0-5    ACV   1.5    TVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV005
Model - TV1
Style - True Vue
0-5 ACV 1.5 TV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV010Model -  TV1Style - True Vue     0-10   ACV   1.5    TVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV010
Model - TV1
Style - True Vue
0-10 ACV 1.5 TV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV015Model -  TV1Style - True Vue     0-15   ACV   1.5    TVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV015
Model - TV1
Style - True Vue
0-15 ACV 1.5 TV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV020Model -  TV1Style - True Vue     0-20   ACV   1.5    TVRating- 0-20 V/ACScale- 0-20Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV020
Model - TV1
Style - True Vue
0-20 ACV 1.5 TV

Rating- 0-20 V/AC
Scale- 0-20
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV025Model -  TV1Style - True Vue     0-25   ACV   1.5    TVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV025
Model - TV1
Style - True Vue
0-25 ACV 1.5 TV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV050Model -  TV1Style - True Vue     0-50   ACV   1.5    TVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV050
Model - TV1
Style - True Vue
0-50 ACV 1.5 TV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV100Model -  TV1Style - True Vue     0-100  ACV   1.5    TVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV100
Model - TV1
Style - True Vue
0-100 ACV 1.5 TV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV150Model -  TV1Style - True Vue     0-150  ACV   1.5    TVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV150
Model - TV1
Style - True Vue
0-150 ACV 1.5 TV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV200Model -  TV1Style - True Vue     0-200  ACV   1.5    TVRating- 0-200 V/ACScale- 0-200Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV200
Model - TV1
Style - True Vue
0-200 ACV 1.5 TV

Rating- 0-200 V/AC
Scale- 0-200
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV250Model -  TV1Style - True Vue     0-250  ACV   1.5    TVRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV250
Model - TV1
Style - True Vue
0-250 ACV 1.5 TV

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV1RVV300Model -  TV1Style - True Vue     0-300  ACV   1.5    TVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV1RVV300
Model - TV1
Style - True Vue
0-300 ACV 1.5 TV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $177.00
Simpson Catalog Number - TV2RVV005Model -  TV2Style - True Vue     0-5    ACV   2.5    TVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV005
Model - TV2
Style - True Vue
0-5 ACV 2.5 TV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV010Model -  TV2Style - True Vue     0-10   ACV   2.5    TVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV010
Model - TV2
Style - True Vue
0-10 ACV 2.5 TV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV015Model -  TV2Style - True Vue     0-15   ACV   2.5    TVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV015
Model - TV2
Style - True Vue
0-15 ACV 2.5 TV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV020Model -  TV2Style - True Vue     0-20   ACV   2.5    TVRating- 0-20 V/ACScale- 0-20Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV020
Model - TV2
Style - True Vue
0-20 ACV 2.5 TV

Rating- 0-20 V/AC
Scale- 0-20
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV025Model -  TV2Style - True Vue     0-25   ACV   2.5    TVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV025
Model - TV2
Style - True Vue
0-25 ACV 2.5 TV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV050Model -  TV2Style - True Vue     0-50   ACV   2.5    TVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV050
Model - TV2
Style - True Vue
0-50 ACV 2.5 TV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV100Model -  TV2Style - True Vue     0-100  ACV   2.5    TVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV100
Model - TV2
Style - True Vue
0-100 ACV 2.5 TV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV150Model -  TV2Style - True Vue     0-150  ACV   2.5    TVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV150
Model - TV2
Style - True Vue
0-150 ACV 2.5 TV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV200Model -  TV2Style - True Vue     0-200  ACV   2.5    TVRating- 0-200 V/AVScale- 0-200Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV200
Model - TV2
Style - True Vue
0-200 ACV 2.5 TV

Rating- 0-200 V/AV
Scale- 0-200
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV250Model -  TV2Style - True Vue     0-250  ACV   2.5    TVRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV250
Model - TV2
Style - True Vue
0-250 ACV 2.5 TV

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV2RVV300Model -  TV2Style - True Vue     0-300  ACV   2.5    TVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV2RVV300
Model - TV2
Style - True Vue
0-300 ACV 2.5 TV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $168.00
Simpson Catalog Number - TV3AVV005Model -  TV3Style - True Vue     0-5    ACV   3.5    TVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV005
Model - TV3
Style - True Vue
0-5 ACV 3.5 TV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $151.00
Simpson Catalog Number - TV3AVV010Model -  TV3Style - True Vue     0-10   ACV   3.5    TVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV010
Model - TV3
Style - True Vue
0-10 ACV 3.5 TV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $151.00
Simpson Catalog Number - TV3AVV015Model -  TV3Style - True Vue     0-15   ACV   3.5    TVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV015
Model - TV3
Style - True Vue
0-15 ACV 3.5 TV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $152.00
Simpson Catalog Number - TV3AVV025Model -  TV3Style - True Vue     0-25   ACV   3.5    TVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV025
Model - TV3
Style - True Vue
0-25 ACV 3.5 TV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $151.00
Simpson Catalog Number - TV3AVV050Model -  TV3Style - True Vue     0-50   ACV   3.5    TVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV050
Model - TV3
Style - True Vue
0-50 ACV 3.5 TV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $155.00
Simpson Catalog Number - TV3AVV100Model -  TV3Style - True Vue     0-100  ACV   3.5    TVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV100
Model - TV3
Style - True Vue
0-100 ACV 3.5 TV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $153.00
Simpson Catalog Number - TV3AVV150Model -  TV3Style - True Vue     0-150  ACV   3.5    TVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV150
Model - TV3
Style - True Vue
0-150 ACV 3.5 TV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $158.00
Simpson Catalog Number - TV3AVV1THModel -  TV3Style - True Vue     0-1000 ACV   3.5    TVRating- 0-500 uA/DCScale- 0-1000Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV1TH
Model - TV3
Style - True Vue
0-1000 ACV 3.5 TV

Rating- 0-500 uA/DC
Scale- 0-1000
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $158.00
Simpson Catalog Number - TV3AVV250Model -  TV3Style - True Vue     0-250  ACV   3.5    TVRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV250
Model - TV3
Style - True Vue
0-250 ACV 3.5 TV

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $157.00
Simpson Catalog Number - TV3AVV300Model -  TV3Style - True Vue     0-300  ACV   3.5    TVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV300
Model - TV3
Style - True Vue
0-300 ACV 3.5 TV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $157.00
Simpson Catalog Number - TV3AVV500Model -  TV3Style - True Vue     0-500  ACV   3.5    TVRating- 0-150 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3AVV500
Model - TV3
Style - True Vue
0-500 ACV 3.5 TV

Rating- 0-150 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $158.00
Simpson Catalog Number - TV3RVV005Model -  TV3Style - True Vue     0-5    ACV   3.5    TVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV005
Model - TV3
Style - True Vue
0-5 ACV 3.5 TV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV010Model -  TV3Style - True Vue     0-10   ACV   3.5    TVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV010
Model - TV3
Style - True Vue
0-10 ACV 3.5 TV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV015Model -  TV3Style - True Vue     0-15   ACV   3.5    TVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV015
Model - TV3
Style - True Vue
0-15 ACV 3.5 TV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV020Model -  TV3Style - True Vue     0-20   ACV   3.5    TVRating- 0-20 V/ACScale- 0-20Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV020
Model - TV3
Style - True Vue
0-20 ACV 3.5 TV

Rating- 0-20 V/AC
Scale- 0-20
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV025Model -  TV3Style - True Vue     0-25   ACV   3.5    TVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV025
Model - TV3
Style - True Vue
0-25 ACV 3.5 TV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV050Model -  TV3Style - True Vue     0-50   ACV   3.5    TVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV050
Model - TV3
Style - True Vue
0-50 ACV 3.5 TV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV100Model -  TV3Style - True Vue     0-100  ACV   3.5    TVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV100
Model - TV3
Style - True Vue
0-100 ACV 3.5 TV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV150Model -  TV3Style - True Vue     0-150  ACV   3.5    TVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV150
Model - TV3
Style - True Vue
0-150 ACV 3.5 TV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV200Model -  TV3Style - True Vue     0-200  ACV   3.5    TVRating- 0-200 V/ACScale- 0-200Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV200
Model - TV3
Style - True Vue
0-200 ACV 3.5 TV

Rating- 0-200 V/AC
Scale- 0-200
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV250Model -  TV3Style - True Vue     0-250  ACV   3.5    TVRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV250
Model - TV3
Style - True Vue
0-250 ACV 3.5 TV

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV3RVV300Model -  TV3Style - True Vue     0-300  ACV   3.5    TVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV3RVV300
Model - TV3
Style - True Vue
0-300 ACV 3.5 TV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $185.00
Simpson Catalog Number - TV4AVV005Model -  TV4Style - True Vue     0-5    ACV   4.5    TVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV005
Model - TV4
Style - True Vue
0-5 ACV 4.5 TV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $159.00
Simpson Catalog Number - TV4AVV010Model -  TV4Style - True Vue     0-10   ACV   4.5    TVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV010
Model - TV4
Style - True Vue
0-10 ACV 4.5 TV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $159.00
Simpson Catalog Number - TV4AVV015Model -  TV4Style - True Vue     0-15   ACV   4.5    TVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV015
Model - TV4
Style - True Vue
0-15 ACV 4.5 TV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $151.00
Simpson Catalog Number - TV4AVV025Model -  TV4Style - True Vue     0-25   ACV   4.5    TVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV025
Model - TV4
Style - True Vue
0-25 ACV 4.5 TV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $159.00
Simpson Catalog Number - TV4AVV050Model -  TV4Style - True Vue     0-50   ACV   4.5    TVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV050
Model - TV4
Style - True Vue
0-50 ACV 4.5 TV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $159.00
Simpson Catalog Number - TV4AVV100Model -  TV4Style - True Vue     0-100  ACV   4.5    TVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV100
Model - TV4
Style - True Vue
0-100 ACV 4.5 TV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $159.00
Simpson Catalog Number - TV4AVV150Model -  TV4Style - True Vue     0-150  ACV   4.5    TVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV150
Model - TV4
Style - True Vue
0-150 ACV 4.5 TV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $167.00
Simpson Catalog Number - TV4AVV1THModel -  TV4Style - True Vue     0-1000 ACV   4.5    TVRating- 0-150 V/ACScale- 0-1000Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV1TH
Model - TV4
Style - True Vue
0-1000 ACV 4.5 TV

Rating- 0-150 V/AC
Scale- 0-1000
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $169.00
Simpson Catalog Number - TV4AVV250Model -  TV4Style - True Vue     0-250  ACV   4.5    TVRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV250
Model - TV4
Style - True Vue
0-250 ACV 4.5 TV

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $159.00
Simpson Catalog Number - TV4AVV300Model -  TV4Style - True Vue     0-300  ACV   4.5    TVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV300
Model - TV4
Style - True Vue
0-300 ACV 4.5 TV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $167.00
Simpson Catalog Number - TV4AVV500Model -  TV4Style - True Vue     0-500  ACV   4.5    TVRating- 0-150 V/ACScale- 0-500Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4AVV500
Model - TV4
Style - True Vue
0-500 ACV 4.5 TV

Rating- 0-150 V/AC
Scale- 0-500
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $167.00
Simpson Catalog Number - TV4RVV005Model -  TV4Style - True Vue     0-5    ACV   4.5    TVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV005
Model - TV4
Style - True Vue
0-5 ACV 4.5 TV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV010Model -  TV4Style - True Vue     0-10   ACV   4.5    TVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV010
Model - TV4
Style - True Vue
0-10 ACV 4.5 TV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV015Model -  TV4Style - True Vue     0-15   ACV   4.5    TVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV015
Model - TV4
Style - True Vue
0-15 ACV 4.5 TV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV020Model -  TV4Style - True Vue     0-20   ACV   4.5    TVRating- 0-20 V/ACScale- 0-20Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV020
Model - TV4
Style - True Vue
0-20 ACV 4.5 TV

Rating- 0-20 V/AC
Scale- 0-20
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV025Model -  TV4Style - True Vue     0-25   ACV   4.5    TVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV025
Model - TV4
Style - True Vue
0-25 ACV 4.5 TV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV050Model -  TV4Style - True Vue     0-50   ACV   4.5    TVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV050
Model - TV4
Style - True Vue
0-50 ACV 4.5 TV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV100Model -  TV4Style - True Vue     0-100  ACV   4.5    TVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV100
Model - TV4
Style - True Vue
0-100 ACV 4.5 TV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV150Model -  TV4Style - True Vue     0-150  ACV   4.5    TVRating- 0-150 V/ACScale- 0-150Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV150
Model - TV4
Style - True Vue
0-150 ACV 4.5 TV

Rating- 0-150 V/AC
Scale- 0-150
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV200Model -  TV4Style - True Vue     0-200  ACV   4.5    TVRating- 0-200 V/ACScale- 0-200Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV200
Model - TV4
Style - True Vue
0-200 ACV 4.5 TV

Rating- 0-200 V/AC
Scale- 0-200
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV250Model -  TV4Style - True Vue     0-250  ACV   4.5    TVRating- 0-250 V/ACScale- 0-250Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV250
Model - TV4
Style - True Vue
0-250 ACV 4.5 TV

Rating- 0-250 V/AC
Scale- 0-250
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV4RVV300Model -  TV4Style - True Vue     0-300  ACV   4.5    TVRating- 0-300 V/ACScale- 0-300Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV4RVV300
Model - TV4
Style - True Vue
0-300 ACV 4.5 TV

Rating- 0-300 V/AC
Scale- 0-300
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $204.00
Simpson Catalog Number - TV6AVV1THModel -  TV6Style - True Vue     0-1000 ACV   4X6    TVRating- 0-150 V/ACScale- 0-1000Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV6AVV1TH
Model - TV6
Style - True Vue
0-1000 ACV 4X6 TV

Rating- 0-150 V/AC
Scale- 0-1000
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $158.00
Simpson Catalog Number - TV6RVV005Model -  TV6Style - True Vue     0-5    ACV   4X6    TVRating- 0-5 V/ACScale- 0-5Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV6RVV005
Model - TV6
Style - True Vue
0-5 ACV 4X6 TV

Rating- 0-5 V/AC
Scale- 0-5
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $206.00
Simpson Catalog Number - TV6RVV010Model -  TV6Style - True Vue     0-10   ACV   4X6    TVRating- 0-10 V/ACScale- 0-10Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV6RVV010
Model - TV6
Style - True Vue
0-10 ACV 4X6 TV

Rating- 0-10 V/AC
Scale- 0-10
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $206.00
Simpson Catalog Number - TV6RVV015Model -  TV6Style - True Vue     0-15   ACV   4X6    TVRating- 0-15 V/ACScale- 0-15Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV6RVV015
Model - TV6
Style - True Vue
0-15 ACV 4X6 TV

Rating- 0-15 V/AC
Scale- 0-15
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $206.00
Simpson Catalog Number - TV6RVV020Model -  TV6Style - True Vue     0-20   ACV   4X6    TVRating- 0-20 V/ACScale- 0-20Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV6RVV020
Model - TV6
Style - True Vue
0-20 ACV 4X6 TV

Rating- 0-20 V/AC
Scale- 0-20
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $206.00
Simpson Catalog Number - TV6RVV025Model -  TV6Style - True Vue     0-25   ACV   4X6    TVRating- 0-25 V/ACScale- 0-25Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV6RVV025
Model - TV6
Style - True Vue
0-25 ACV 4X6 TV

Rating- 0-25 V/AC
Scale- 0-25
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $206.00
Simpson Catalog Number - TV6RVV050Model -  TV6Style - True Vue     0-50   ACV   4X6    TVRating- 0-50 V/ACScale- 0-50Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV6RVV050
Model - TV6
Style - True Vue
0-50 ACV 4X6 TV

Rating- 0-50 V/AC
Scale- 0-50
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $206.00
Simpson Catalog Number - TV6RVV100Model -  TV6Style - True Vue     0-100  ACV   4X6    TVRating- 0-100 V/ACScale- 0-100Legend- AC VOLTS - Product Image

Simpson Catalog Number - TV6RVV100
Model - TV6
Style - True Vue
0-100 ACV 4X6 TV

Rating- 0-100 V/AC
Scale- 0-100
Legend- AC VOLTS

Manufacture: Simpson
Product Description:
  • Clear acrylic case updates panel design
  • Black knife edge pointer for precision reading
  • Special colored scales or logos available


Product PDF
 
 Price: $206.00