W.E.I. Inc. offers AEMC's full line of megohmmeters with test voltages 50V to 5000V. Capability to measure insulation resistance up to 10TΩ. These rugged, weather resistant meters are accurate, reliable and built to perform. Battery, AC Powered & Hand-cranked models available.
Over-molded slip-proof holster for rugged field use
EN 61010-1, 300V Cat. II, EN 61557
Supplied with a soft carrying case and test leads
Application: Motor insulation resistance measurements, Continuity checks, Test industrial commercial wiring & motor control centers, Test motors (AC & DC), Test transformers, Dielectric Absorption Ratio and Polarization Index measurements.
Over-molded slip-proof holster for rugged field use
Supplied with a soft carrying case and test leads
Application: Motor insulation resistance measurements, Continuity checks, Low resistance measurement, Test industrial commercial wiring & motor control centers, Test motors (AC & DC), Test transformers, Dielectric Absorption Ratio and Polarization Index measurements.
Over-molded slip-proof holster for rugged field use
Supplied with a soft carrying case and test leads
Application: Motor insulation resistance measurements, Continuity checks, Low resistance measurement, Test industrial commercial wiring & motor control centers, Test motors (AC & DC), Test transformers, Dielectric Absorption Ratio and Polarization Index measurements.
Over-molded slip-proof holster for rugged field use
Application: Motor insulation resistance measurements, Continuity checks, Low resistance measurement, Test industrial commercial wiring & motor control centers, Test motors (AC & DC), Test transformers, Dielectric Absorption Ratio and Polarization Index measurements.
Over-molded slip-proof holster for rugged field use
Application: Motor insulation resistance measurements, Continuity checks, Low resistance measurement, Test industrial commercial wiring & motor control centers, Test motors (AC & DC), Test transformers, Dielectric Absorption Ratio and Polarization Index measurements.
Test voltage combinationss of 50V, 100V, 250V and 500V
Insulation measurements to 20,000Mohm 20Gohm
Automatic test inhibition if live sample >25V
Automatic discharge for operator safety
Alarm indication
Multi-line 4000-count digital display with analog bargraph
Over-molded slip-proof holster for rugged field use
Supplied with a soft carrying case and test leads
Application: Motor insulation resistance measurements, Continuity checks, Low resistance measurement, Test industrial commercial wiring & motor control centers, Test motors (AC & DC), Test transformers, Dielectric Absorption Ratio and Polarization Index measurements.
Multi-line 4000-count digital display with analog bargraph
Over-molded slip-proof holster for rugged field use
Supplied with a soft carrying case and test leads
Application: Cable testing (including telecom), Motor insulation resistance measurements, Continuity checks, Low resistance measurement, Test industrial commercial wiring & motor control centers, Test motors (AC & DC), Test transformers, Dielectric Absorption Ratio and Polarization Index measurements.
Test voltage combinations of 50V, 100V, 250V and 500V
Insulation measurements to 20,000Mohm (20Gohm)
Automatic test inhibition if live sample >25V
Automatic discharge for operator safety
Alarm indication
Multi-line 4000-count digital display with analog bargraph
Over-molded slip-proof holster for rugged field use
Application: Motor insulation resistance measurements, Continuity checks, Low resistance measurement, Test industrial commercial wiring & motor control centers, Test motors (AC & DC), Test transformers, Dielectric Absorption Ratio and Polarization Index measurements.
Multi-line 4000-count digital display with analog bargraph
Over-molded slip-proof holster for rugged field use
Application: Cable testing (including telecom), Motor insulation resistance measurements, Continuity checks, Low resistance measurement, Test industrial commercial wiring & motor control centers, Test motors (AC & DC), Test transformers, Dielectric Absorption Ratio and Polarization Index measurements.
Test voltage combinations of 50V, 100V, 250V, 500V and 1000V
Insulation measurement to 4000Gohm (4Tohm)
Direct measurement of DAR and PI values
Direct measurement of sample Capacitance
Display of test voltage and run time
Programmable test run times and PI times
Smooth and Alarm functions
Automatic test inhibition if live sample >25V
Automatic discharge after use with voltage display
Large dual display with time, voltage and measurement
Bright blue electrolumenescent backlight
Battery powered
Auto power-down when not in use
Remote operation with optional test probe
Rugged dual wall weatherproof field case with detachable lead/accessory pouch
EN 61010-1, 600V Cat. III
Application: Test insulation on cables, transformers, motors and wiring installations, High resistance or absorption tests, Spot reading tests, Timed resistance measurements, Dielectric (DAR) and polarization (PI) tests, Low insulation test range for testing old or flooded installations, Motor insulation resistance measurements, Continuity checks and low resistance measurements, and Computer controlled production line testing.
Test voltage combinations of 50V, 100V, 250V, 500V and 1000V
Insulation measurement to 4000Gohm (4Tohm)
Direct measurement of DAR and PI values
Direct measurement of sample Capacitance
Display of test voltage and run time
Programmable test run times and PI times
Smooth and Alarm functions
Automatic test inhibition if live sample >25V
Automatic discharge after use with voltage display
Large dual display with time, voltage and measurement
Bright blue electroluminescent backlight
Remote operation with optional test probe
Rugged, dual wall, weatherproof field case with detachable lead/accessory pouch
AC rechargeable NiMH batteries
RS-232 interface for direct printing of results
Remote operation through PC
Includes software to configure instrument and generate reports
Application: Test insulation on cables, transformers, motors and wiring installations, High resistance or absorption tests, Spot reading tests, Timed resistance measurements, Dielectric (DAR) and polarization (PI) tests, Low insulation test range for testing old or flooded installations, Motor insulation resistance measurements, Continuity checks and low resistance measurements, Computer controlled production line testing, and Predictive maintenance by storing results in PC for trend analysis.
Test voltage combination of 500V, 1000V, 2500V and 5000V
Insulation measurements from 30kohm to 10Tohm
Adjustable and programmable test voltage (40 to 5100V)
Automatic calculation of DAR, PI and DD values
Direct measurement and display of Capacitance and Leakage Current
Display resistance, test voltage and run time
Programmable test run times and PI ratio times
Smooth and Alarm functions
Automatic test inhibition if live sample (>25)
Automatic discharge and display of discharge voltage
Large dual-display with time, voltage and measurements shown
Rugged dual wall weatherproof field case
Designed and built to IEC safety standards
EN 61010-1, 600V Cat. III
Application: Test insulation on cables, transformers, motors, generators, insulators and wiring installations, High resistance or absorption tests, Spot reading tests, Timed resistance measurements, Dielectric Absorption Ratio (DAR) and Polarization Index (PI) tests, Multi-layer insulation testing (DD), Test old or water damaged installations over long time runs, Motor insulation resistance measurements, Computer controlled production line testing, Predictive maintenance by storing results in PC for trend analysis, and User selectable voltage testing to provide application specific testing.
Test voltage combination of 500V, 1000V, 2500V and 5000V
Insulation measurements from 30kohm to 10Tohm
Adjustable and programmable test voltage (40 to 5100V)
Automatic calculation of DAR, PI and DD values
Direct measurement and display of Capacitance and Leakage Current
Display resistance, test voltage and run time
Programmable test run times and PI ratio times
Smooth and Alarm functions
Automatic test inhibition if live sample (>25)
Automatic discharge and display of discharge voltage
Large dual-display with time, voltage and measurements shown
Rugged weatherproof field case
RS-232 interface for direct printing of results
128kB memory for storing field test data
Remote operation from PC
Includes DataView software
Application: Test insulation on cables, transformers, motors, generators, insulators and wiring installations, High resistance or absorption tests, Spot reading tests, Timed resistance measurements, Dielectric Absorption Ratio (DAR) and Polarization Index (PI) tests, Multi-layer insulation testing (DD), Test old or water damaged installations over long time runs, Motor insulation resistance measurements, Computer controlled production line testing, Predictive maintenance by storing results in PC for trend analysis, and User selectable voltage testing to provide application specific testing.
True Megohmmeter with selectable test voltage from 40 to 5100V, and fixed test voltages of 500V, 1000V, 2500V and 5000V
Insulation measurements from 30kohm to 10Tohm
Automatic step voltage with programmable step and dwell times - three profiles can be stored, each with up to five steps
Programmable temperature compensation of resistance readings
Automatic calculation of DAR, PI and DD values
Direct measurement and display of Resistance, Test Voltage, Run Time, Capacitance and Leakage Current
Automatic test inhibition if live voltage is present
Automatic discharge and display of discharge voltage
Large graphic display with five line alphanumeric display and graph of all test results
Rugged weatherproof field case
RS-232 interface for direct printing of results
128kB memory for storing field test data
Remote operation from PC
Includes DataView software
Application: Test insulation on cables, transformers, motors, generators, insulators and wiring installations, High resistance or absorption tests, Spot reading tests, Timed resistance measurements, Dielectric Absorption Ratio (DAR) and Polarization Index (PI) tests, Multi-layer insulation testing (DD), Test old or water damaged installations over long time runs, Motor insulation resistance measurements, Computer controlled production line testing, Predictive maintenance by storing results in PC for trend analysis, and User selectable voltage testing to provide application specific testing.
Test button may be locked-on for three minutes for hands-free operation
Automatic discharge when test button is released
Low battery indication
Supplied with a soft carrying case and test leads
Application: Test insulation on cables, transformers, motors, insulators and wiring installations, High resistance or absorption tests, Spot reading tests, Timed resistance measurements, Dielectric (DAR) and polarization (PI) tests, Low insulation test range for testing old or flooded installations, Motor insulation resistance measurements, Continuity checks and low resistance measurements, Computer controlled production line testing, and Predictive maintenance by storing results in PC for trend analysis.
Supplied with a yellow, non-slip, shockproof rubber housing and soft carrying case
Designed to international and safety standards
CE Mark
Application: Acceptance testing and preventive maintenance, Motors (AC and DC), transformers, cables, Heaters, relays, circuit breakers, Continuity checks, Domestic and industrial contracting, Rugged construction design for mining, industrial, heavy-duty field, offshore and military applications.
Test voltage combination of 500V, 1000V, 2500V and 5000V
Insulation measurements from 30kohm to 10Tohm
Adjustable and programmable test voltage (40 to 5100V)
Automatic calculation of DAR and PI values
Direct measurement and display of Capacitance and Leakage Current
Display of resistance, test voltage and run time
Programmable test run times and PI ratio times
Automatic test inhibition if live sample (>25)
Automatic discharge and display of discharge voltage
Large dual-display with time, voltage and measurements shown
Rugged dual wall weatherproof field case
Designed and built to IEC safety standards
EN 61010-1, 1000V CAT III
Application: Test insulation on cables, transformers, motors, generators, insulators and wiring installations, High resistance or absorption tests, Spot reading tests, Timed resistance measurements, Dielectric Absorption Ratio (DAR) and Polarization Index (PI) tests, Test old or water damaged installations over long time runs, and Motor insulation resistance measurements.
Supplied with a yellow, non-slip, shockproof rubber housing and soft carrying case
Designed to international and safety standards
Application: Acceptance testing and preventive maintenance, Motors (AC and DC), transformers, cables, Heaters, relays, circuit breakers, Continuity checks, Domestic and industrial contracting, Rugged construction designed for mining, industrial, heavy-duty field, offshore and military applications.